Low energy alpha particles dose mapping with a combination of CR-39 detector and a high resolution flatbed scanner

被引:1
作者
Mohamed, Amal [1 ,2 ]
Abdel-Mageed, M. [2 ]
El Ghazaly, M. [2 ]
El-Naggar, Hala, I [3 ]
Aboelmaaref, Amal [4 ]
Al-Sayed, A. [2 ,5 ]
机构
[1] Umm Al Qura Univ, Fac Sci, Phys Dept, Mecca, Saudi Arabia
[2] Zagazig Univ, Fac Sci, Dept Phys, Zagazig 44519, Egypt
[3] Benha Univ, Fac Sci, Dept Phys, Banha 13518, Egypt
[4] Helwan Univ, Fac Sci, Chem Dept, Cairo 11795, Egypt
[5] Qassim Univ, Coll Sci, Dept Phys, Buraydah, Saudi Arabia
关键词
CR-39; detector; alpha particles; radiation dose; color channel; canon CanScan 9000F mark II; optical density; TRACKS;
D O I
10.1088/1402-4896/ad4f2c
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The potential of a combination of the well-known CR-39 detector and a high-resolution flatbed scanner for low energy alpha particles dose mapping is investigated. The CR-39 detectors were irradiated with perpendicular incident 4 MeV alpha particles of doses 0.009, 0.018, 0.033, 0.051, 0.067, 0.134, and 0.164 Gy, thereafter, etched in 6.25 N NaOH at 70 degrees C. The CR-39 detectors were scanned with Canon CanScan 9000F Mark II of spatial resolution of 9600 dpi and color depth of 48 bit. The measurements reveal that the pixel values for different color channels are correlated linearly with 4 MeV alpha particles dose at the etching times of 2 h, 3 h, and 4 h. For blue channel, the maximum sensitivity was -53178 +/- 1463 pixel value/Gy at etching time of 4 h, compared to -15290 +/- 2004 pixel value/Gy, and -42255 +/- 840 pixel value/Gy at 2 h and 3 h respectively, the negative sign indicates the pixel values decrease as the 4 MeV alpha particles dose increases. While for etching times, 5 h and 6 h, the pixel values decrease exponentially as the 4 MeV alpha particles dose increases. For prolonged etching time, the pixel values are non-monotonic function of alpha particles dose. The optical density was evaluated as a function of etching time (removal thickness) of CR-39 irradiated with different doses. For 0.009 Gy, and 0.018 Gy doses of alpha particles, the optical density is linearly correlated with the etching time; for other doses, the optical density is not a monotonic function of the etching time. These new findings pave the way to use the combination of the CR-39 detector and high-resolution flatbed scanner for dose mapping of alpha particles and heavy ions over large-scale areas, applying etching conditions for each particle type and corresponding energy, that produce maximum sensitivity and linearity.
引用
收藏
页数:10
相关论文
共 29 条
[1]   Alpha particle spectrometry based on the mean grey level and visibility of track etch-pit in CR-39 Nuclear Track Detector [J].
Al-Sayed, A. ;
El Ghazaly, M. ;
Ghanim, E. H. ;
Mohamed, Amal ;
El-Naggar, Hala, I ;
Dawood, Mahmoud S. .
PHYSICA SCRIPTA, 2022, 97 (05)
[2]  
Aydarous A., 2013, INT J MATH COMPUTATI, V7, P1174, DOI DOI 10.5281/ZEN0D0.1087324
[3]   Investigation of energy dependance for EBT3 response to irradiation with alpha beams [J].
Basset, A. ;
Koumeir, C. ;
Chiavassa, S. ;
Delpon, G. ;
Le Deroff, C. ;
Frelin, A. -M. ;
Guertin, A. ;
Haddad, F. ;
Metivier, V. ;
Michel, N. ;
Poirier, F. ;
Servagent, N. ;
Varmenot, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 454 :56-60
[4]  
BATALLER G, 1989, RADIAT PROT DOSIM, V26, P217
[5]  
Bhattacharyya R., 2019, Perspectives in Science, V12, DOI [10.1016/j.pisc.2019.100404, DOI 10.1016/J.PISC.2019.100404]
[6]   On the alpha particles of radium, and their loss of range in passing through various atoms and molecules [J].
Bragg, W. H. ;
Elder, M. A. .
PHILOSOPHICAL MAGAZINE, 1905, 10 (55-60) :318-340
[7]  
cityu.edu.hk, About us
[8]   Radiochromic film dosimetry: Past, present, and future [J].
Devic, Slobodan .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (03) :122-134
[9]  
Durrani SA., 1987, SOLID STATE NUCL TRA
[10]   Characterization of saturation of CR-39 detector at high alpha-particle fluence [J].
El Ghazaly, M. ;
Hassan, Nabil M. .