Size variability and fitting of 30-gauge thin-wall needles and 3-piece intraocular lens haptics for the flanged intrascleral fixation technique

被引:2
作者
Pukl, Spela Stunf [1 ,2 ,3 ]
Kronschlager, Martin [1 ]
Ruiss, Manuel [1 ]
Blouin, Stephane [4 ]
Findl, Oliver [1 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg VIROS, Heinrich Collin Str 30, AT-1140 Vienna, Austria
[2] Univ Ljubljana, Med Fac, Ljubljana, Slovenia
[3] Univ Clin Ctr Ljubljana, Eye Hosp, Ljubljana, Slovenia
[4] Hanusch Hosp, Med Dept, Ludwig Boltzmann Inst Osteol, OGK & AUVA Trauma Ctr Meidling, Vienna, Austria
关键词
D O I
10.1097/j.jcrs.0000000000001210
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the diameter of different 30-gauge thin-wall needles and 3-piece intraocular lens (IOL) haptics readily used for the flanged-haptic intrascleral fixation technique. Setting: Hanusch Hospital, Vienna, Austria. Design: Laboratory investigation. Methods: 5 30-gauge thin-wall needles and 5 3-piece IOLs were assessed. An upright light microscopy was used for measurements. The inner and outer diameters of the needles and the end thickness of the haptics were analyzed and compared for haptic fitting into the needle. Results: Among the needles, the inner diameter of the T-lab needle was significantly wider compared with all the others (mean 209.3 +/- 8.0 mu m, P < .001), followed by TSK (194.8 +/- 5.0 mu m), MST (194.7 +/- 5.8 mu m), Sterimedix (187.5 +/- 9.0 mu m) and significantly narrower Meso-relle (mean 178.7 +/- 7.0 mu m, P < .05). The outer diameter of the T-lab needle was significantly larger of all (mean 316.0 +/- 2.0 mu m, P < .001). Concerning the IOLs, the AvanseePreset Kowa's haptic was significantly thinner (mean 127.2 +/- 0.7 mu m) than all the others, such as the TecnisZA900 Johnson & Johnson (143.5 +/- 3.1 mu m), the CTLucia202 Zeiss (143.8 +/- 1.3 mu m), and the AcrysofMA60AC Alcon (143.9 +/- 1.4 mu m). The only haptic that was thicker than all the others assessed was that of SensarAR40 Johnson & Johnson (170.7 +/- 1.7 mu m, P < .001). Conclusions: Most of the analyzed haptics would fit into most of the measured needles, with the exception of the Sensar AR40 in combination with the Meso-relle or Sterimedix needles. The combination of a larger needle lumen and a thinner haptic could result in more ease of insertion during surgery. If the dimensions of the needle and IOL haptics used are unknown, we recommend trying insertion before beginning surgery.
引用
收藏
页码:874 / 878
页数:5
相关论文
共 10 条
[1]   Standardized Flanged Intrascleral Intraocular Lens Fixation with the Double-Needle Technique for Cataract Luxation in the Vitreous Chamber during Phacoemulsification [J].
Besozzi, Gianluca ;
Posarelli, Chiara ;
Costa, Maria Carmela ;
Montericcio, Alessio ;
Nitti, Giuseppe ;
Giancipoli, Ermete ;
L'Abbate, Milena ;
Pignatelli, Francesco ;
Parolini, Barbara ;
Figus, Michele .
JOURNAL OF OPHTHALMOLOGY, 2021, 2021
[2]   The novel haptic-twist method for a sutureless double-needle intrascleral haptic fixation technique [J].
Erakgun, Tansu ;
Gobeka, Hamidu Hamisi .
INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (09) :3013-3020
[3]   A Modified Flanged Intrascleral Intraocular Lens Fixation Technique Using an Externalized Needle for Haptic Docking [J].
Ifantides, Cristos ;
Naids, Steven M. ;
Muttuvelu, Danson, V ;
Mian, Shahzad, I ;
Christopher, Karen L. .
CLINICAL OPHTHALMOLOGY, 2021, 15 :2047-2050
[4]   Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience [J].
Kelkar, Aditya Shrikant ;
Fogla, Rajesh ;
Kelkar, Jai ;
Kothari, Akshay Anil ;
Mehta, Hetal ;
Amoaku, Winfried .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) :1450-1453
[5]   Trailing-haptic-first modification of double-needle intrascleral haptic fixation technique [J].
Kim, Dooho Brian .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04) :424-428
[6]   Attaining the optimal flange for intrascleral intraocular lens fixation [J].
Kronschlaeger, Martin ;
Blouin, Stephane ;
Roschger, Paul ;
Varsits, Ralph ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (11) :1303-1305
[7]   Long-Term Stability of Intraocular Lens with Trimmed or Untrimmed Haptics in Yamane Sutureless Intrascleral Fixation Technique [J].
Lin, Hui ;
Ye, Xiancheng ;
Huang, Xinyu ;
Li, Houshuo ;
Wang, Zhen ;
Niu, Yunli ;
Bi, Yanlong .
MEDICAL SCIENCE MONITOR, 2021, 27
[8]  
Muth Daniel Rudolf, 2022, Am J Ophthalmol Case Rep, V26, P101502, DOI 10.1016/j.ajoc.2022.101502
[9]   Double-Needle Yamane Technique Using Flanged Haptics in Ocular Trauma-A Retrospective Survey of Visual Outcomes and Safety [J].
Nowomiejska, Katarzyna ;
Haszcz, Dariusz ;
Onyszkiewicz, Maksymilian ;
Choragiewicz, Tomasz ;
Czarnek-Chudzik, Aleksandra ;
Szpringer-Wabicz, Agata ;
Baltaziak, Katarzyna ;
Brzozowska, Agnieszka ;
Toro, Mario Damiano ;
Rejdak, Robert .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (12)
[10]   Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique [J].
Yamane, Shin ;
Sato, Shimpei ;
Maruyama-Inoue, Maiko ;
Kadonosono, Kazuaki .
OPHTHALMOLOGY, 2017, 124 (08) :1136-1142