Analysis of energy performance and load matching characteristics of various building integrated photovoltaic (BIPV) systems in office building

被引:8
作者
Wang, Meng [1 ]
Zhao, Xi [1 ]
Li, Sihui [1 ]
Yang, Zhirui [2 ]
Liu, Keke [1 ]
Wen, Zihan [1 ]
Li, Yonghuan [1 ]
Peng, Jinqing [2 ]
机构
[1] Changsha Univ Sci & Technol, Sch Energy & Power Engn, Changsha 410114, Hunan, Peoples R China
[2] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Building integrated photovoltaic (BIPV); PV rooftop; PV window: shading; Load matching; SEMITRANSPARENT PV; WINDOW; CONSUMPTION; GENERATION; FACADES; DESIGN;
D O I
10.1016/j.jobe.2024.110313
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building Integrated Photovoltaic (BIPV) is a key technology for achieving zero-energy buildings by generating electricity and reducing energy consumption. Although many studies have analyzed the impact of BIPV on building energy efficiency, there is a lack of comprehensive comparative analysis of various BIPV systems. This study compared the impact of various BIPV systems on office building energy performance and provided optimal solutions for different climate zones. Simulation models for PV rooftop, PV window, and PV shading systems were developed and validated in EnergyPlus. The energy performance of BIPV systems in different Chinese climates was evaluated using these models. The results show that the PV window and PV shading have the most power generation capability in Beijing, and the PV rooftop has the most power generation capability in Kunming. Energy savings in Kunming are the highest with PV rooftop, PV windows, and PV shading at 111.78 %, 39.36 %, and 44.43 %, respectively. Finally, the study calculated the self-sufficiency rate (SSR) and self-consumption rate (SCR), and their ratio, along with the load matching ratio, were used to assess loading matching. Optimal BIPV schemes were identified for each climate zone, revealing that the PV rooftop combined with the PV shading system achieved the best load matching in Kunming, Guangzhou, Changsha, Beijing, and Harbin, with ratios of 82.00 %, 69.38 %, 70.88 %, 74.78 % and 67.27 %, respectively. These results provide a valuable reference for implementing the BIPV system to achieve zero energy consumption in office buildings under different climatic conditions in China.
引用
收藏
页数:20
相关论文
共 47 条
[1]   Occupancy-based one-year-ahead heating, ventilation, and air-conditioning electricity consumption optimization using machine learning [J].
Alaraj, Maher ;
Parodi, Marianela ;
Radi, Mohammed ;
Alsisi, Elaf ;
Abbod, Maysam F. ;
Majdalawieh, Munir .
JOURNAL OF BUILDING ENGINEERING, 2023, 80
[2]   Up-to-date literature review on Solar PV systems: Technology progress market status and R&D , [J].
Allouhi, Amine ;
Rehman, Shafiqur ;
Buker, Mahmut Sami ;
Said, Zafar .
JOURNAL OF CLEANER PRODUCTION, 2022, 362
[3]   Thermal performance evaluation and energy saving potential of semi-transparent CdTe in Facade BIPV [J].
Alrashidi, Hameed ;
Issa, Walid ;
Sellami, Nazmi ;
Sundaram, Senthilarasu ;
Mallick, Tapas .
SOLAR ENERGY, 2022, 232 :84-91
[4]   A comprehensive analysis of small-scale building integrated photovoltaic system for residential buildings: Techno-economic benefits and greenhouse gas mitigation potential [J].
Anand, Abhishek ;
Verayiah, Renuga A. P. ;
Mansor, Muhamad ;
Hasim, Tengku Juhana Tengku ;
Shukla, Amritanshu ;
Panchal, Hitesh ;
Sharma, Atul ;
Natrayan, L. ;
Kumar, Abhinav .
JOURNAL OF BUILDING ENGINEERING, 2024, 82
[5]   Assessment of the efficiency of window integrated CdTe based semi-transparent photovoltaic module [J].
Barman, Sankar ;
Chowdhury, Amartya ;
Mathur, Sanjay ;
Mathur, Jyotirmay .
SUSTAINABLE CITIES AND SOCIETY, 2018, 37 :250-262
[6]   Investigation of annual performance of a building shaded by rooftop PV panels in different climate zones of India [J].
Bhuvad, Sushant Suresh ;
Udayraj .
RENEWABLE ENERGY, 2022, 189 :1337-1357
[7]   Impact of simulation time-resolution on the matching of PV production and household electric demand [J].
Cao, Sunliang ;
Siren, Kai .
APPLIED ENERGY, 2014, 128 :192-208
[8]   Case study of the upgrade of an existing office building for low energy consumption and low carbon emissions [J].
Charles, Alexandra ;
Maref, Wahid ;
Ouellet-Plamondon, Claudiane M. .
ENERGY AND BUILDINGS, 2019, 183 :151-160
[9]   Experimental and numerical evaluation of the crystalline silicon PV window under the climatic conditions in southwest China [J].
Chen, Mo ;
Zhang, Wei ;
Xie, Lingzhi ;
Ni, Zhichun ;
Wei, Qingzhu ;
Wang, Wei ;
Tian, Hao .
ENERGY, 2019, 183 :584-598
[10]  
EnergyPlus, 2022, EnergyPlus 22.1