Evaluation of the Pulmonary Arteries on CTPA With Dual Energy CT: Objective Analysis and Subjective Preferences in a Multireader Study

被引:1
作者
Gliner-Ron, Masha [1 ]
Sosna, Jacob [1 ]
Leichter, Isaac [1 ]
Goldberg, S. Nahum [1 ]
Shaham, Dorit [1 ]
Cohen, Dotan [1 ]
Malul, Yehuda [1 ]
Romman, Zimam [1 ]
Lev-Cohain, Naama [1 ]
机构
[1] Hebrew Univ Jerusalem, Fac Med, Hadassah Med Ctr, Dept Radiol, IL-9112102 Jerusalem, Israel
关键词
dual-energy CT; pulmonary embolism; signal-to-noise ratio; contrast-to-noise ratio; radiologists; MULTIDETECTOR COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CHEST CT; ANGIOGRAPHY; EMBOLISM; DIAGNOSIS;
D O I
10.1097/RTI.0000000000000782
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform qualitative and quantitative evaluation of low-monoenergetic images (50 KeV) compared with conventional images (120 kVp) in pulmonary embolism (PE) studies and to determine the extent and clinical relevance of these differences as well as radiologists' preferences. Materials and Methods: One hundred fifty CT examinations for PE detection conducted on a single-source dual-energy CT were retrospectively evaluated. Attenuation, contrast-to-noise-ratio, and signal-to-noise-ratio were obtained in a total of 8 individual pulmonary arteries on each exam-including both central (450/1200=37.5%) and peripheral (750/1200=62.5%) locations. Results were compared between the conventional and low-monoenergetic images. For quality assessment, 41 images containing PE were presented side-by-side as pairs of slices in both conventional and monoenergetic modes and evaluated for ease in embolus detection by 9 radiologists: cardiothoracic specialists (3), noncardiothoracic specialists (3), and residents (3). Paired samples t tests, a-parametric Wilcoxon test, McNemar test, and kappa statistics were performed. Results: Monoenergetic images had an overall statistically significant increased average ratio of 2.09 to 2.26 (P<0.05) for each measured vessel attenuation, with an increase in signal-to-noise ratio (23.82 +/- 9.29 vs. 11.39 +/- 3.2) and contrast-to-noise ratio (17.17 +/- 6.7 vs 7.27 +/- 2.52) (P<0.05). Moreover, 10/150 (6%) of central pulmonary artery measurements considered suboptimal on conventional mode were considered diagnostic on the monoenergetic images (181 +/- 14.6 vs. 387.7 +/- 72.4 HU respectively, P<0.05). In the subjective evaluation, noncardiothoracic radiologists showed a preference towards low-monoenergetic images, whereas cardiothoracic radiologists did not (74.4% vs. 57.7%, respectively, P<0.05). Conclusions: The SNR and CNR increase on monoenergetic images may have clinical significance particularly in the setting of sub-optimal PE studies. Noncardiothoracic radiologists and residents prefer low monoenergetic images.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 26 条
[1]   Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT [J].
Bae, Kyungsoo ;
Jeon, Kyung Nyeo ;
Cho, Soo Buem ;
Park, Sung Eun ;
Moon, Jin Il ;
Baek, Hye Jin ;
Choi, Bo Hwa .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (04) :734-741
[2]   Image Quality of Low-Energy Pulmonary CT Angiography: Comparison With Standard CT [J].
Bogot, Naama R. ;
Fingerle, Alexander ;
Shaham, Dorith ;
Nissenbaum, Izhak ;
Sosna, Jacob .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) :W273-W278
[3]   Utility of virtual monoenergetic images derived from a dual-layer detector-based spectral CT in the assessment of aortic anatomy and pathology: A retrospective case control study [J].
Chalian, Hamid ;
Kalisz, Kevin ;
Rassouli, Negin ;
Dhanantwari, Amar ;
Rajiah, Prabhakar .
CLINICAL IMAGING, 2018, 52 :292-301
[4]   Diagnosis of acute pulmonary embolism in outpatients: Comparison of thin-collimation multi-detector row spiral CT and planar ventilation-perfusion scintigraphy [J].
Coche, E ;
Verschuren, F ;
Keyeux, A ;
Goffette, P ;
Goncette, L ;
Hainaut, P ;
Hammer, F ;
Lavenne, E ;
Zech, F ;
Meert, P ;
Reynaert, MS .
RADIOLOGY, 2003, 229 (03) :757-765
[5]   Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography [J].
D'Angelo, Tommaso ;
Bucher, Andreas M. ;
Lenga, Lukas ;
Arendt, Christophe T. ;
Peterke, Julia L. ;
Caruso, Damiano ;
Mazziotti, Silvio ;
Blandino, Alfredo ;
Ascenti, Giorgio ;
Othman, Ahmed E. ;
Martin, Simon S. ;
Leithner, Doris ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2018, 28 (04) :1393-1401
[6]   State-of-the-Art Imaging in Pulmonary Embolism: Ventilation/Perfusion Single-Photon Emission Computed Tomography versus Computed Tomography Angiography Controversies, Results, and Recommendations from a Systematic Review [J].
Hess, Soren ;
Frary, Evan C. ;
Gerke, Oke ;
Madsen, Poul Henning .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2016, 42 (08) :833-845
[7]   Dual-Energy CT: General Principles [J].
Johnson, Thorsten R. C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S3-S8
[8]   The indeterminate CT pulmonary angiogram: Imaging characteristics and patient clinical outcome [J].
Jones, SE ;
Wittram, C .
RADIOLOGY, 2005, 237 (01) :329-337
[9]   Dual-Energy CT with Single- and Dual-Source Scanners: Current Applications in Evaluating the Genitourinary Tract [J].
Kaza, Ravi K. ;
Platt, Joel F. ;
Cohan, Richard H. ;
Caoili, Elaine M. ;
Al-Hawary, Mahmoud M. ;
Wasnik, Ashish .
RADIOGRAPHICS, 2012, 32 (02) :353-369
[10]   Intravenous contrast material administration at high-pitch dual-source CT pulmonary angiography: Test bolus versus bolus-tracking technique [J].
Kerl, J. Matthias ;
Lehnert, Thomas ;
Schell, Boris ;
Bodelle, Boris ;
Beeres, Martin ;
Jacobi, Volkmar ;
Vogl, Thomas J. ;
Bauer, Ralf W. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) :2887-2891