An electrochemiluminescence biosensor based on target-responsive DNA hydrogel for T-2 toxin

被引:0
|
作者
Cai, Siqi [1 ]
Li, Dejun [1 ]
Luo, Fang [1 ]
Lin, Zhenyu [1 ]
Huang, Aiwen [2 ]
Qiu, Bin [1 ]
机构
[1] Fuzhou Univ, Key Lab Analyt Sci Food Safety & Biol, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] 900TH Hosp Joint Logist Support Force, Clin Pharm Dept, Fuzhou 350001, Fujian, Peoples R China
关键词
Electrochemiluminescence; DNA hydrogel; T-2; toxin; Luminol; LUMINOL; DELIVERY; GLUCOSE; HPLC;
D O I
10.1016/j.microc.2024.111231
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, an electrochemiluminescence (ECL) biosensor for T-2 toxin detection has been designed by combining the high specificity of a DNA hydrogel system with the convenience and sensitivity of homogeneous ECL detection. Specifically, A hydrogel was engineered through the reaction between the carboxyl group of hyaluronic acid (HA) and the amino groups of both polyethyleneimine (PEI) and DNA-modified strands, resulting in a three-dimensional network that encapsulates glucose oxidase. Glucose oxidase (GOD) is capable of catalyzing the conversion of glucose into hydrogen peroxide (H2O2), which is a co-reactant necessary for the chemiluminescent reagent luminol to emit light. Upon the presence of the target analyte T-2 toxin, the aptamer recognizes and binds to it, leading to the dissociation and cleavage of the hydrogel framework. This process results in the leakage of the encapsulated GOD into the supernatant. Subsequently, Adding the collected supernatant to a phosphate-buffered saline (PBS) solution containing glucose and luminol for ECL testing yields a noticeable signal change. This sensor eliminates the need for electrode modification, simplifying the operation. Within a concentration range of 10 fg/mL to 100 ng/mL, the ECL signal intensity exhibits an excellent linear relationship with the logarithm of the target concentration, with a detection limit as low as 0.32 fg/mL. The method also demonstrates excellent reproducibility and stability. The sensor demonstrated precise detection capabilities in actual milk and beer samples, a crucial aspect for research focused on specific targets.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Hydrogel SERS chip with strong localized surface plasmon resonance for sensitive and rapid detection of T-2 toxin
    Chen, Mingming
    Su, Bihang
    Wu, Huiying
    Dai, Yawen
    Chen, Tianwen
    Fu, Fengfu
    Lin, Zhenyu
    Dong, Yongqiang
    TALANTA, 2024, 268
  • [32] The effect of T-2 toxin on bone microstructure in rabbits
    Babosova, Ramona
    Omelka, Radoslav
    Duranova, Hana
    Lukacova, Martina
    Mondockova, Vladimira
    Bauerova, Maria
    Capcarova, Marcela
    Martiniakova, Monika
    BIOLOGIA, 2018, 73 (01) : 101 - 106
  • [33] Synthesis and application of a T-2 toxin imprinted polymer
    De Smet, David
    Monbaliu, Sofie
    Dubruel, Peter
    Van Peteghem, Carlos
    Schacht, Etienne
    De Saeger, Sarah
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) : 2879 - 2886
  • [34] Enzymatic hydrolysis of T-2 toxin for the quantitative determination of total T-2 and HT-2 toxins in cereals
    Lattanzio, Veronica M. T.
    Solfrizzo, Michele
    Visconti, Angelo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (05) : 1325 - 1334
  • [35] Cas12a-based electrochemiluminescence biosensor for target amplification-free DNA detection
    Liu, Peng-Fei
    Zhao, Kai-Ren
    Liu, Zhi-Jun
    Wang, Li
    Ye, Shu-Ying
    Liang, Guo-Xi
    BIOSENSORS & BIOELECTRONICS, 2021, 176
  • [36] A novel electrochemiluminescence aptasensor using Ti3C2@AuNRs-Ru for ultra-sensitive detection of T-2 toxin
    Zhang, Junyi
    Deng, Ye
    Chen, Lifen
    Luo, Fang
    Weng, Zuquan
    Lin, Cuiying
    Qiu, Bin
    Guo, Longhua
    Lin, Zhenyu
    ELECTROCHIMICA ACTA, 2024, 475
  • [37] Human Biomonitoring of T-2 Toxin, T-2 Toxin-3-Glucoside and Their Metabolites in Urine through High-Resolution Mass Spectrometry
    Narvaez, Alfonso
    Izzo, Luana
    Pallares, Noelia
    Castaldo, Luigi
    Rodriguez-Carrasco, Yelko
    Ritieni, Alberto
    TOXINS, 2021, 13 (12)
  • [38] A G-quadruplex-assisted target-responsive dual-mode aptasensor based on copper nanoclusters synthesized in situ in a DNA hydrogel for ultrasensitive detection of ochratoxin A
    Fan, Pengfei
    Li, Qianji
    Zhang, Zhengduo
    Jiang, Ping
    Zhang, Zhan
    Wu, Qian
    Li, Lei
    TALANTA, 2024, 270
  • [39] Building a Fluorescent Aptasensor Based on Exonuclease-Assisted Target Recycling Strategy for One-Step Detection of T-2 Toxin
    He, Deyun
    Wu, Zhengzong
    Cui, Bo
    Xu, Enbo
    Jin, Zhengyu
    FOOD ANALYTICAL METHODS, 2019, 12 (02) : 625 - 632
  • [40] JNK molecule is a toxic target for IPEC-J2 cell barrier damage induced by T-2 toxin
    Chen, Fengjuan
    Wang, Youshuang
    Chen, Yunhe
    Fan, Jiayan
    Zhang, Cong
    He, Xiuyuan
    Yang, Xu
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2023, 263