摘要
Ultrasound-guided percutaneous interventions have numerous advantages over traditional techniques. Accurate needle placement in the target anatomy is crucial for successful intervention, and reliable visual information is essential to achieve this. However, previous studies have revealed several challenges, such as the variability in needle echogenicity and the common misalignment of the ultrasound beam and the needle. Advanced techniques have been developed to optimize needle visualization, including hardware-based and image-processing-based methods. This paper proposes a novel strategy of integrating ultrasound-based deep learning approaches into an optical navigation system to enhance needle visualization and improve tip positioning accuracy. Both the tracking and detection algorithms are optimized utilizing optical tracking information. The information is introduced into the tracking network to define the search patch update strategy and form a trajectory reference to correct tracking results. In the detection network, the original image is processed according to the needle insertion position and current position given by the optical localization system to locate a coarse region, and the depth-score criterion is adopted to optimize detection results. Extensive experiments demonstrate that our approach achieves promising tip tracking and detection performance with tip localization errors of 1.11 $\pm $ 0.59 mm and 1.17 $\pm$ 0.70 mm, respectively. Moreover, we establish a paired dataset consisting of ultrasound images and their corresponding spatial tip coordinates acquired from the optical tracking system and conduct real puncture experiments to verify the effectiveness of the proposed methods. Our approach significantly improves needle visualization and provides physicians with visual guidance for posture adjustment.
引用
收藏
页码:2930 / 2942
页数:13
相关论文
共 31 条
[1]   Automatic needle detection and real-time Bi-planar needle visualization during 3D ultrasound scanning of the liver [J].
Arif, Muhammad ;
Moelker, Adriaan ;
van Walsum, Theo .
MEDICAL IMAGE ANALYSIS, 2019, 53 :104-110
[2]   Needle Tip Visibility in 3D Ultrasound Images [J].
Arif, Muhammad ;
Moelker, Adriaan ;
van Walsum, Theo .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (01) :145-152
[3]   Optical Flow-Based Tracking of Needles and Needle-Tip Localization Using Circular Hough Transform in Ultrasound Images [J].
Ayvali, Elif ;
Desai, Jaydev P. .
ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (08) :1828-1840
[4]   The 2014 liver ultrasound tracking benchmark [J].
De Luca, V. ;
Benz, T. ;
Kondo, S. ;
Koenig, L. ;
Luebke, D. ;
Rothluebbers, S. ;
Somphone, O. ;
Allaire, S. ;
Bell, M. A. Lediju ;
Chung, D. Y. F. ;
Cifor, A. ;
Grozea, C. ;
Guenther, M. ;
Jenne, J. ;
Kipshagen, T. ;
Kowarschik, M. ;
Navab, N. ;
Ruehaak, J. ;
Schwaab, J. ;
Tanner, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14) :5571-5599
[5]  
Deng J, 2009, PROC CVPR IEEE, P248, DOI 10.1109/CVPRW.2009.5206848
[6]   Robust Needle Localization and Enhancement Algorithm for Ultrasound by Deep Learning and Beam Steering Methods [J].
Gao, Jun ;
Liu, Paul ;
Liu, Guang-Di ;
Zhang, Le .
JOURNAL OF COMPUTER SCIENCE AND TECHNOLOGY, 2021, 36 (02) :334-346
[7]   Advantages of Optical Compared with Electromagnetic Tracking [J].
Glossop, Neil D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A :23-28
[8]   Precision of coaxial needle placement in computed tomography-guided transthoracic needle biopsy [J].
Huang, Rui ;
Jiang, Nan-Chuan ;
Lu, Hao-Hao ;
Wang, Yu-Hui ;
Li, Hui ;
Shi, He-Shui ;
Han, Ping .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (05) :1307-1311
[9]   The effect of needle tip tracking on procedural time of ultrasound-guided lumbar plexus block: a randomised controlled trial [J].
Kasine, T. ;
Romundstad, L. ;
Rosseland, L. A. ;
Ullensvang, K. ;
Fagerland, M. W. ;
Kessler, P. ;
Bjorna, E. ;
Sauter, A. R. .
ANAESTHESIA, 2020, 75 (01) :72-79
[10]   Needle tip tracking for ultrasound-guided peripheral nerve block procedures-An observer blinded, randomised, controlled, crossover study on a phantom model [J].
Kasine, Trine ;
Romundstad, Luis ;
Rosseland, Leiv Arne ;
Ullensvang, Kyrre ;
Fagerland, Morten Wang ;
Hol, Per Kristian ;
Kessler, Paul ;
Sauter, Axel Rudolf .