Effect of central dialysis fluid delivery system using high flux dialyzer versus regular water treatment stations on endotoxemia and inflammatory markers among prevalent patients on regular hemodialysis

被引:0
作者
Tawfik, Ahmed Mohamed [1 ]
Elshinnawy, Howaida Abd Elhamid [1 ]
Elsayed, Hesham Mohamed [1 ]
Said, Heba Wahid El [1 ]
Hammoda, Hoda Mohamed [1 ]
El Samea, Marwa Shaban Abd [1 ]
机构
[1] Ain Shams Univ, Fac Med, Dept Nephrol, Cairo, Egypt
来源
ELECTRONIC JOURNAL OF GENERAL MEDICINE | 2024年 / 21卷 / 03期
关键词
central dialysis fluid delivery system; flux dialyzer; endotoxemia; inflammatory markers; hemodialysis; ULTRAPURE DIALYSATE; LEVEL; RISK;
D O I
10.29333/ejgm/14653
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: In this study, we compared the effects of a single patient dialysis fluid delivery system (SPDDS) against a central dialysis fluid delivery system (CDDS) on inflammatory markers and endotoxemia in a population of patients receiving routine hemodialysis (HD). Materials & methods: 80 prevalent HD patients, aged from 18 to 60 years old, who were clinically stable and receiving thrice weekly dialysis treatments via an arteriovenous fistula were the subjects of a cross-sectional research. group I underwent HD using a CDDS water purification system that was implemented at El Demerdash Hospital two years prior, and group II underwent HD using an SPDDS water purification system at Ain Shams Results: Pre-dialysis endotoxin levels were significantly lower in the CDDS group (0.07 +/- 0.05) compared to the SPDDS group (0.20 +/- 0.07), p-value<0.001, post-dialysis serum endotoxin levels were significantly lower in CDDS group (0.04 +/- 0.02) compared to SDDPS (0.15 +/- 0.03), p-value<0.001. Conclusions: CDDS group's circulating endotoxins had significantly decreased.
引用
收藏
页数:7
相关论文
共 19 条
[1]   The Effect of Exercise on Nutritional Status and Body Composition in Hemodialysis: A Systematic Review [J].
Bakaloudi, Dimitra Rafailia ;
Siargkas, Antonios ;
Poulia, Kalliopi Anna ;
Dounousi, Evangelia ;
Chourdakis, Michail .
NUTRIENTS, 2020, 12 (10) :1-33
[2]   Online hemodiafiltration reduces systemic inflammation compared to low-flux hemodialysis [J].
den Hoedt, Claire H. ;
Bots, Michiel L. ;
Grooteman, Muriel P. C. ;
van der Weerd, Neelke C. ;
Mazairac, Albert H. A. ;
Penne, E. Lars ;
Levesque, Renee ;
ter Wee, Piet M. ;
Nube, Menso J. ;
Blankestijn, Peter J. ;
van den Dorpel, Marinus A. .
KIDNEY INTERNATIONAL, 2014, 86 (02) :423-432
[3]   Mechanisms for hemodynamic instability related to renal replacement therapy: a narrative review [J].
Douvris, Adrianna ;
Zeid, Khalid ;
Hiremath, Swapnil ;
Bagshaw, Sean M. ;
Wald, Ron ;
Beaubien-Souligny, William ;
Kong, Jennifer ;
Ronco, Claudio ;
Clark, Edward G. .
INTENSIVE CARE MEDICINE, 2019, 45 (10) :1333-1346
[4]  
Elsayed H, ISN WORLD C NEPHR ME
[5]  
Elsayed HM., 2021, INT J MED MUSHROOMS, DOI [10.1093/qjmed/hcab100.012, DOI 10.1093/QJMED/HCAB100.012]
[6]   Dialysis Fluid Endotoxin Level and Mortality in Maintenance Hemodialysis: A Nationwide Cohort Study [J].
Hasegawa, Takeshi ;
Nakai, Shigeru ;
Masakane, Ikuto ;
Watanabe, Yuzo ;
Iseki, Kunitoshi ;
Tsubakihara, Yoshiharu ;
Akizawa, Tadao .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2015, 65 (06) :899-904
[7]   Endotoxemia is associated with acute coronary syndrome in patients with end stage kidney disease [J].
Hsu, Chien-Chin ;
Wei, Tsui-Shan ;
Huang, Chien-Cheng ;
Chen, Yi-Ming .
BMC NEPHROLOGY, 2017, 18
[8]   Cardiovascular risk of circulating endotoxin level in prevalent hemodialysis patients [J].
Ibrahim, Mohamed ;
Behairy, Maha ;
El-Ashry, Marwa ;
Mostafa, Ahmad E. .
EGYPTIAN HEART JOURNAL, 2018, 70 (01) :27-33
[9]  
Kawanishi H, 2016, REGION SPACE CULT, V2, P1
[10]   Advances and Advantages in Recent Central Dialysis Fluid Delivery System [J].
Koda, Yutaka ;
Mineshima, Michio .
BLOOD PURIFICATION, 2009, 27 :23-27