Optimizing Root Canal Therapy: An In Vitro Comparative Study of Innovative File Systems on Mandibular Premolar Fracture Resistance

被引:0
作者
Shruthi, P. [1 ]
Krishna, M. Jaya Nagendra [1 ]
Reddy, Jayaprada [1 ]
Kumar, N. Nikhil [1 ]
Jayyarapu, Dilip [2 ]
Punna, Rajani [1 ]
Divya, R. [1 ]
Anuhya, S. [1 ]
机构
[1] Kamineni Inst Dent Sci, Conservat Dent & Endodont, Nalgonda, India
[2] Kamineni Inst Dent Sci, Prosthodont, Nalgonda, India
关键词
xp - endo shaper; self adjusting file; reciproc; mandibular premolars; fracture resistance; XP-ENDO SHAPER; SELF-ADJUSTING FILE; DENTINAL MICROCRACKS; INSTRUMENTS; GOLD;
D O I
10.7759/cureus.62077
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and aim: Root canal therapy is a vital procedure for saving teeth by removing infection and cleaning the complex root canal system. However, a delicate balance exists between thorough cleaning and preserving tooth strength. The study aims to evaluate the instrumentation effect of three innovative file systems, XP-endo (R) shaper, Reciproc (R), and Self-adjusting file (SAF) on fracture resistance of mandibular premolars. Materials and methods: Thirty single-rooted mandibular premolars were collected; a standard access cavity was prepared and the working length was established 1 mm short of the apex. The teeth were randomly divided into three groups(n=10). In Group 1, the shaping of the specimens was achieved using XP-endo (R) shaper; in Group 2, it was instrumented using Reciproc (R) file; and in Group 3, it was instrumented using SAF. All samples were decoronated and the roots were mounted vertically in acrylic resin and subjected to fracture resistance under a universal testing machine. Results: Intergroup analysis was done by one-way ANOVA followed by Bonferroni post hoc test, which did not report a statistically significant difference (p>0.05). Conclusion: All three tested file systems were similar in fracture resistance. XP-endo (R) shaper exhibited better fracture resistance on root canal instrumentation when compared to Reciproc (R) and SAF although they are not statistically significant.
引用
收藏
页数:9
相关论文
共 27 条
[11]  
Katta PK, 2022, J Res Med Dent Sci., V10, P15
[12]   Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture [J].
Kim, Hyeon-Cheol ;
Lee, Min-Ho ;
Yum, Jiwan ;
Versluis, Antheunis ;
Lee, Chan-Joo ;
Kim, Byung-Min .
JOURNAL OF ENDODONTICS, 2010, 36 (07) :1195-1199
[13]   Nickel-Titanium Rotary Instruments: Development of the Single-File Systems [J].
Kuzekanani, Maryam .
JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2018, 8 (05) :386-390
[14]   Vertical Root Fracture in Non-Endodontically and Endodontically Treated Teeth: Current Understanding and Future Challenge [J].
Liao, Wan-Chuen ;
Chen, Chi-Hung ;
Pan, Yu-Hwa ;
Chang, Mei-Chi ;
Jeng, Jiiang-Huei .
JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (12)
[15]   Incidence of Apical Root Cracks and Apical Dentinal Detachments after Canal Preparation with Hand and Rotary Files at Different Instrumentation Lengths [J].
Liu, Rui ;
Kaiwar, Anjali ;
Shemesh, Hagay ;
Wesselink, Paul R. ;
Hou, Benxiang ;
Wu, Min-Kai .
JOURNAL OF ENDODONTICS, 2013, 39 (01) :129-132
[16]  
Mardani M, 2020, J Res Dent Maxillofac Sci, V5, P31, DOI [10.29252/jrdms.5.4.37, DOI 10.29252/JRDMS.5.4.37]
[17]  
Metzger Zvi, 2014, J Conserv Dent, V17, P401, DOI 10.4103/0972-0707.139820
[18]  
Pawar Ajinkya M, 2016, J Conserv Dent, V19, P138, DOI 10.4103/0972-0707.178692
[19]   Impact of Access Cavity Design and Root Canal Taper on Fracture Resistance of Endodontically Treated Teeth: An Ex Vivo Investigation [J].
Sabeti, Mohammad ;
Kazem, Majid ;
Dianat, Omid ;
Bahrololumi, Nazanin ;
Beglou, Amirreza ;
Rahimipour, Kasra ;
Dehnavi, Farshad .
JOURNAL OF ENDODONTICS, 2018, 44 (09) :1402-1406
[20]   Shaping Ability and Buckling Resistance of TruNatomy, WaveOne gold, and XP-Endo Shaper Single-File Systems [J].
Shaheen, Neveen Ali ;
Elhelbawy, Nahla Gamal Eldin .
CONTEMPORARY CLINICAL DENTISTRY, 2022, 13 (03) :261-266