Characterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery

被引:2
作者
Deut, Umberto [1 ,2 ]
Camperi, Aurora [2 ]
Cavicchi, Cristiano [3 ]
Cirio, Roberto [1 ,2 ]
Data, Emanuele Maria [1 ,2 ]
Durisi, Elisabetta Alessandra [1 ,2 ]
Ferrero, Veronica [1 ,2 ]
Ferro, Arianna [1 ,2 ]
Giordanengo, Simona [2 ]
Villarreal, Oscar Marti [4 ]
Mas Milian, Felix [1 ,2 ,5 ]
Medina, Elisabetta [1 ,2 ]
Olivares, Diango M. Montalvan [1 ,2 ]
Mostardi, Franco [1 ,2 ]
Monti, Valeria [1 ,2 ]
Sacchi, Roberto [1 ,2 ]
Salmeri, Edoardo [3 ]
Vignati, Anna [1 ,2 ]
机构
[1] Univ Turin, Dept Phys, I-10125 Turin, Italy
[2] Natl Inst Nucl Phys INFN, Sect Turin, I-10125 Turin, Italy
[3] Elekta SpA, I-20864 Agrate Brianza, Italy
[4] Bruno Kessler Fdn FBK, Ctr Sensors & Devices, I-38122 Trento, Italy
[5] Univ Estadual Santa Cruz, Dept Exact & Technol Sci, BR-45662900 Ilheus, Brazil
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 17期
关键词
ultra-high dose rate; FLASH radiotherapy; LINAC; dosimetry; electron beam; silicon sensors; GafChromic films; IRRADIATION; DOSIMETRY;
D O I
10.3390/app14177582
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Irradiations at Ultra-High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radiotherapy with reduced harm to normal tissues. This work details the hardware and software modifications implemented to deliver 10 MeV UHDR electron beams with a linear accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for dosimetry characterization, while a silicon sensor assessed the machine's beam pulses stability and repeatability. The dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface distance and the beam collimation, i.e., with and without the use of a cylindrical applicator. The results showed a dose per pulse from 0.6 Gy to a few tens of Gy and an average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in vitro radiobiology experiments and test new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field.
引用
收藏
页数:14
相关论文
共 27 条
[1]   Dosimetry for FLASH Radiotherapy: A Review of Tools and the Role of Radioluminescence and Cherenkov Emission [J].
Ashraf, Muhammad Ramish ;
Rahman, Mahbubur ;
Zhang, Rongxiao ;
Williams, Benjamin B. ;
Gladstone, David J. ;
Pogue, Brian W. ;
Bruza, Petr .
FRONTIERS IN PHYSICS, 2020, 8
[2]   Technical note: Commissioning of a linear accelerator producing ultra-high dose rate electrons [J].
Cetnar, Ashley J. ;
Jain, Sagarika ;
Gupta, Nilendu ;
Chakravarti, Arnab .
MEDICAL PHYSICS, 2024, 51 (02) :1415-1420
[3]   Assessment of clinically relevant dose distributions in pelvic IOERT using Gafchromic EBT3 films [J].
Costa, Filipa ;
Sarmento, Sandra ;
Sousa, Olga .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07) :692-701
[4]   Enabling ultra-high dose rate electron beams at a clinical linear accelerator for isocentric treatments [J].
Dal Bello, Riccardo ;
von der Grun, Jens ;
Fabiano, Silvia ;
Rudolf, Thomas ;
Saltybaeva, Natalia ;
Stark, Luisa S. ;
Ahmed, Md ;
Bathula, Manohar ;
Dogan, Serpil Kucuker ;
McNeur, Joshua ;
Guckenberger, Matthias ;
Tanadini-Lang, Stephanie .
RADIOTHERAPY AND ONCOLOGY, 2023, 187
[5]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[6]   FLASH Radiotherapy With Electrons: Issues Related to the Production, Monitoring, and Dosimetric Characterization of the Beam [J].
Di Martino, Fabio ;
Barca, Patrizio ;
Barone, Salvatore ;
Bortoli, Eleonora ;
Borgheresi, Rita ;
De Stefano, Silvia ;
Di Francesco, Massimo ;
Faillace, Luigi ;
Giuliano, Lucia ;
Grasso, Luigi ;
Linsalata, Stefania ;
Marfisi, Daniela ;
Migliorati, Mauro ;
Pacitti, Matteo ;
Palumbo, Luigi ;
Felici, Giuseppe .
FRONTIERS IN PHYSICS, 2020, 8
[7]   Perspectives in linear accelerator for FLASH VHEE: Study of a compact C-band system [J].
Faillace, L. ;
Alesini, D. ;
Bisogni, G. ;
Bosco, F. ;
Carillo, M. ;
Cirrone, P. ;
Cuttone, G. ;
De Arcangelis, D. ;
De Gregorio, A. ;
Di Martino, F. ;
Favaudon, V. ;
Ficcadenti, L. ;
Francescone, D. ;
Franciosini, G. ;
Gallo, A. ;
Heinrich, S. ;
Migliorati, M. ;
Mostacci, A. ;
Palumbo, L. ;
Patera, V. ;
Patriarca, A. ;
Pensavalle, J. ;
Perondi, F. ;
Remetti, R. ;
Sarti, A. ;
Spataro, B. ;
Torrisi, G. ;
Vannozzi, A. ;
Giuliano, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 :149-159
[8]   Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice [J].
Favaudon, Vincent ;
Caplier, Laura ;
Monceau, Virginie ;
Pouzoulet, Frederic ;
Sayarath, Mano ;
Fouillade, Charles ;
Poupon, Marie-France ;
Brito, Isabel ;
Hupe, Philippe ;
Bourhis, Jean ;
Hall, Janet ;
Fontaine, Jean-Jacques ;
Vozenin, Marie-Catherine .
SCIENCE TRANSLATIONAL MEDICINE, 2014, 6 (245)
[9]   Electron FLASH radiotherapy in vivo studies. A systematic review [J].
Giannini, Noemi ;
Gadducci, Giovanni ;
Fuentes, Taiusha ;
Gonnelli, Alessandra ;
Di Martino, Fabio ;
Puccini, Paola ;
Naso, Monica ;
Pasqualetti, Francesco ;
Capaccioli, Simone ;
Paiar, Fabiola .
FRONTIERS IN ONCOLOGY, 2024, 14
[10]   Radiobiological Aspects of FLASH Radiotherapy [J].
Hageman, Eline ;
Che, Pei-Pei ;
Dahele, Max ;
Slotman, Ben J. ;
Sminia, Peter .
BIOMOLECULES, 2022, 12 (10)