Glycated hemoglobin (HbA1c) and biofluid-based diagnosis in diabetes: A comprehensive review

被引:0
作者
Chowdhury, Jaba Roy [1 ]
Peringeth, Kiran [1 ,2 ]
Ganguly, Anindita [1 ,3 ]
Necesario, Sydney Rechie S. [1 ]
Hsieh, Wu-Chiao [1 ,4 ]
Ra, Yoonsang [5 ]
Choi, Dongwhi [5 ]
Lin, Zong-Hong [1 ,3 ,5 ]
机构
[1] Natl Taiwan Univ, Dept Biomed Engn, Taipei 10617, Taiwan
[2] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu 30013, Taiwan
[3] Natl Tsing Hua Univ, Internet Senses Res Ctr, Hsinchu 30013, Taiwan
[4] Chang Gung Mem Hosp, Dept Obstet & Gynecol, Taoyuan 33305, Taiwan
[5] Kyung Hee Univ, Dept Mech Engn Integrated Engn Program, Yongin 17104, Gyeonggi Do, South Korea
关键词
Electrochemical sensors; Diabetes management; Glycated hemoglobin; Glucose; Wearable sensing; Biofluid based detection; HUMAN ECCRINE SWEAT; BLOOD-GLUCOSE; ADULT PATIENTS; HBA(1C); ACID; BIOSENSOR; ELECTRODE; RISK; NANOPARTICLES; CONSTRUCTION;
D O I
10.1016/j.jelechem.2024.118301
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The global rise in diabetes has fueled new developments in wearable devices. Diabetes, characterized by high glucose levels and impaired insulin secretion, causes a variety of complications. Diabetes rates in Southeast Asia and the Western Pacific are alarmingly high, with projections of a significant increase by 2045. The economic burden in the Asia-Pacific region is expected to reach USD 881.03 billion by 2030. Due to the unreliability of traditional blood glucose readings, glycated hemoglobin (HbA1c) has emerged as a stable biomarker that provides a consistent view of glycemic status over 2-3 months. Despite effective hospital-based HbA1c measurements, labor-intensive methods limit their use. Wearable systems that investigate glucose levels in alternative biofluids have promising potential for continuous monitoring, particularly in prediabetes cases. Current monitoring systems, while effective, are uncomfortable and expensive. This review examines diabetes diagnosis with HbA1c and biofluid-based sensors, focusing on blood-based evaluations and the complementary nature of glucose and HbA1c sensors. It emphasizes the critical importance of combining biofluid-based diagnosis with HbA1c measurement for effective diabetes management.
引用
收藏
页数:23
相关论文
共 168 条
  • [61] Glycated hemoglobin detection with electrochemical sensing amplified by gold nanoparticles embedded N-doped graphene nanosheet
    Jain, Utkarsh
    Chauhan, Nidhi
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 89 : 578 - 584
  • [62] Javaid Mohammad A, 2016, J Oral Biol Craniofac Res, V6, P66, DOI 10.1016/j.jobcr.2015.08.006
  • [63] Quantification of cortisol in human eccrine sweat by liquid chromatography - tandem mass spectrometry
    Jia, Min
    Chew, Wade M.
    Feinstein, Yelena
    Skeath, Perry
    Sternberg, Esther M.
    [J]. ANALYST, 2016, 141 (06) : 2053 - 2060
  • [64] Kaul S., 2020, SN COMPUT SCI, V1, P1, DOI [10.1007/s42979-020-00337-2, DOI 10.1007/S42979-020-00337-2]
  • [65] Different strategies for detection of HbA1c emphasizing on biosensors and point-of-care analyzers
    Kaur, Jagjit
    Jiang, Cheng
    Liu, Guozhen
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 123 : 85 - 100
  • [66] Influence of enzyme immobilization and skin-sensor interface on non-invasive glucose determination from interstitial fluid obtained by magnetohydrodynamic extraction
    Kemp, Emily
    Palomaki, Tommi
    Ruuth, Ida A.
    Boeva, Zhanna A.
    Nurminen, Teemu A.
    Vanska, Risto T.
    Zschaechner, Laura K.
    Perez, Alejandro Garcia
    Hakala, Tuuli A.
    Wardale, Melissa
    Haeggstrom, Edward
    Bobacka, Johan
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 206
  • [67] Wireless smart contact lens for diabetic diagnosis and therapy
    Keum, Do Hee
    Kim, Su-Kyoung
    Koo, Jahyun
    Lee, Geon-Hui
    Jeon, Cheonhoo
    Mok, Jee Won
    Mun, Beom Ho
    Lee, Keon Jae
    Kamrani, Ehsan
    Joo, Choun-Ki
    Shin, Sangbaie
    Sim, Jae-Yoon
    Myung, David
    Yun, Seok Hyun
    Bao, Zhenan
    Hahn, Sei Kwang
    [J]. SCIENCE ADVANCES, 2020, 6 (17):
  • [68] Simultaneous Detection of Serum Glucose and Glycated Albumin on a Paper-Based Sensor for Acute Hyperglycemia and Diabetes Mellitus
    Ki, Hangil
    Jang, Hyungjun
    Oh, Jusung
    Han, Gyeo-Re
    Lee, Hoyeon
    Kim, Sanghyo
    Kim, Min-Gon
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (17) : 11530 - 11534
  • [69] Wearable biosensors for healthcare monitoring
    Kim, Jayoung
    Campbell, Alan S.
    de Avila, Berta Esteban-Fernandez
    Wang, Joseph
    [J]. NATURE BIOTECHNOLOGY, 2019, 37 (04) : 389 - 406
  • [70] Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
    Kim, Jayoung
    Jeerapan, Itthipon
    Imani, Somayeh
    Cho, Thomas N.
    Bandodkar, Amay
    Cinti, Stefano
    Mercier, Patrick P.
    Wang, Joseph
    [J]. ACS SENSORS, 2016, 1 (08): : 1011 - 1019