The detection of elemental content changes in electrode coating using laser-induced breakdown spectroscopy

被引:0
作者
Yang, Lei [1 ]
Li, Yinchuan [1 ]
Pan, Congyuan [2 ]
Bao, Wenyi [1 ]
Qin, Lei [1 ]
Dong, Jingtao [1 ]
Xu, Mengjie [1 ]
Ji, Feng [1 ]
Zhang, Yuzhong [1 ]
Lu, Rongsheng [1 ]
机构
[1] Hefei Univ Technol, Anhui Prov Engn Res Ctr Semicond Inspection Techno, Sch Instrument Sci & Optoelect Engn, Anhui Prov Key Lab Measuring Theory & Precis Instr, Hefei 230009, Anhui, Peoples R China
[2] Anhui Prov Hefei GStar Intelligent Control Tech Co, Hefei 230088, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser-induced breakdown spectroscopy; lithium battery; Electrode coating; Elemental content change; Internal mixed matrix; QUANTITATIVE-ANALYSIS; CATHODE; PERFORMANCE; CALIBRATION; LI; NANOPARTICLES; SPECTROMETRY;
D O I
10.1016/j.sab.2024.106896
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The elemental content of battery electrode coating is prone to change due to the production technology and ambient factors. To ensure the consistent performance and safety of a lithium battery, the elemental content of the electrode coating needs to be kept strictly consistent. This study proposes an internal mixed matrix method that combines laser-induced breakdown spectroscopy and chemometric method to achieve rapid and accurate detection of elemental content changes in electrode coating. The stoichiometric ratios of analytical elements are calculated by using the spectra of laser-induced breakdown spectroscopy. The relationships between that stoichiometric ratios and the actual content of analytical elements are studied and show that they are linear. Thus, the content change of the analytical element can be determined by calculating the change of the stoichiometric ratio. The average relative errors for content changes of iron, lithium, and phosphorus are 6.43%, 2.96%, and 4.12%, respectively, and the lowest detection limits are 278.2 mg/kg, 20.5 mg/kg, and 105.4 mg/kg, respectively. Furthermore, the internal reference method is proposed to correct the effect of ambient gases and improve detection accuracy. The results are that when Fe I 372.751 nm and Fe I 373.485 nm are used as analytical lines, after correcting for the effect of ambient gases, the average relative errors of Fe content changes are reduced by 62% and 72%, respectively, and the lowest detection limits are increased by 67% and 71%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Analysis of Pharmaceutical Tablet Coating Uniformity by Laser-Induced Breakdown Spectroscopy (LIBS)
    Dubey, Atul
    Keyvan, Golshid
    Hsia, Richard
    Saranteas, Kostas
    Brone, Dean
    Misra, Tushar
    Muzzio, Fernando J.
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2011, 6 (02) : 77 - 87
  • [42] Feasibility of Trace Alcohol Congener Detection and Identification Using Laser-Induced Breakdown Spectroscopy
    Zhang Jialiang
    Wang Shangmin
    Zhao Lixian
    Liu Liying
    Wang Dezhen
    PLASMA SCIENCE & TECHNOLOGY, 2014, 16 (12) : 1119 - 1125
  • [43] Laser-Induced Breakdown Spectroscopy for Chemical Mapping of Materials
    Pinon, V.
    Mateo, M. P.
    Nicolas, G.
    APPLIED SPECTROSCOPY REVIEWS, 2013, 48 (05) : 357 - 383
  • [44] Determination of fluorine content in rocks using laser-induced breakdown spectroscopy assisted with radical synthesis
    Li, Qingzhou
    Zhang, Wen
    Tang, Zhiyang
    Liu, Ke
    Zhu, Chenwei
    Zhou, Ran
    Liu, Kun
    Li, Xiangyou
    TALANTA, 2021, 234
  • [45] Laser-induced breakdown spectroscopy for rapid and accurate qualitative analysis of elemental composition in fertilizers
    Nisar, Sobia
    Alsalme, Ali
    Zulfiqar, Rimsha
    Rizwan, Muhammad
    Kim, Deok-Kee
    Dastgeer, Ghulam
    Shazad, Zafar Muhammad
    MODERN PHYSICS LETTERS B, 2024, 38 (15):
  • [46] Effects of moisture content on coal analysis using laser-induced breakdown spectroscopy
    Chen, Mengyuan
    Yuan, Tingbi
    Hou, Zongyu
    Wang, Zhe
    Wang, Yun
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 112 : 23 - 33
  • [47] Elemental Analysis of Black Salt by Laser-Induced Breakdown Spectroscopy and Inductively Coupled Plasma-Optical Emission Spectroscopy
    Qasim, M.
    Anwar-ul-Haq, M.
    Afgan, M. Sher
    Kalyar, M. A.
    Baig, M. A.
    ANALYTICAL LETTERS, 2016, 49 (13) : 2108 - 2118
  • [48] Determination of Carbon Content in Steels Using Laser-Induced Breakdown Spectroscopy Assisted with Laser-Induced Radical Fluorescence
    Li, Jiaming
    Zhu, Zhihao
    Zhou, Ran
    Zhao, Nan
    Yi, Rongxing
    Yang, Xinyan
    Li, Xiangyou
    Guo, Lianbo
    Zeng, Xiaoyan
    Luo, Yongfeng
    ANALYTICAL CHEMISTRY, 2017, 89 (15) : 8134 - 8139
  • [49] Review of Laser-Induced Breakdown Spectroscopy in Gas Detection
    He Ya-xiong
    Zhou Wen-qi
    Ke Chuan
    Xu Tao
    Zhao Yong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (09) : 2681 - 2687
  • [50] Detection of early caries by laser-induced breakdown spectroscopy
    Sasazawa, Shuhei
    Kakino, Satoko
    Matsuura, Yuji
    CLINICAL AND BIOMEDICAL SPECTROSCOPY AND IMAGING IV, 2015, 9537