The detection of elemental content changes in electrode coating using laser-induced breakdown spectroscopy

被引:0
|
作者
Yang, Lei [1 ]
Li, Yinchuan [1 ]
Pan, Congyuan [2 ]
Bao, Wenyi [1 ]
Qin, Lei [1 ]
Dong, Jingtao [1 ]
Xu, Mengjie [1 ]
Ji, Feng [1 ]
Zhang, Yuzhong [1 ]
Lu, Rongsheng [1 ]
机构
[1] Hefei Univ Technol, Anhui Prov Engn Res Ctr Semicond Inspection Techno, Sch Instrument Sci & Optoelect Engn, Anhui Prov Key Lab Measuring Theory & Precis Instr, Hefei 230009, Anhui, Peoples R China
[2] Anhui Prov Hefei GStar Intelligent Control Tech Co, Hefei 230088, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser-induced breakdown spectroscopy; lithium battery; Electrode coating; Elemental content change; Internal mixed matrix; QUANTITATIVE-ANALYSIS; CATHODE; PERFORMANCE; CALIBRATION; LI; NANOPARTICLES; SPECTROMETRY;
D O I
10.1016/j.sab.2024.106896
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The elemental content of battery electrode coating is prone to change due to the production technology and ambient factors. To ensure the consistent performance and safety of a lithium battery, the elemental content of the electrode coating needs to be kept strictly consistent. This study proposes an internal mixed matrix method that combines laser-induced breakdown spectroscopy and chemometric method to achieve rapid and accurate detection of elemental content changes in electrode coating. The stoichiometric ratios of analytical elements are calculated by using the spectra of laser-induced breakdown spectroscopy. The relationships between that stoichiometric ratios and the actual content of analytical elements are studied and show that they are linear. Thus, the content change of the analytical element can be determined by calculating the change of the stoichiometric ratio. The average relative errors for content changes of iron, lithium, and phosphorus are 6.43%, 2.96%, and 4.12%, respectively, and the lowest detection limits are 278.2 mg/kg, 20.5 mg/kg, and 105.4 mg/kg, respectively. Furthermore, the internal reference method is proposed to correct the effect of ambient gases and improve detection accuracy. The results are that when Fe I 372.751 nm and Fe I 373.485 nm are used as analytical lines, after correcting for the effect of ambient gases, the average relative errors of Fe content changes are reduced by 62% and 72%, respectively, and the lowest detection limits are increased by 67% and 71%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Association of commingled human skeletal remains by their elemental profile using handheld laser-induced breakdown spectroscopy
    Kuehn, Kelsi
    Livingston, Kristen M.
    Bethard, Jonathan D.
    Baudelet, Matthieu
    FORENSIC SCIENCE INTERNATIONAL, 2025, 367
  • [32] Laser-induced breakdown spectroscopy in China
    Zhe Wang
    Ting-Bi Yuan
    Zong-Yu Hou
    Wei-Dong Zhou
    Ji-Dong Lu
    Hong-Bin Ding
    Xiao-Yan Zeng
    Frontiers of Physics, 2014, 9 : 419 - 438
  • [33] Laser-induced breakdown spectroscopy in China
    Wang, Zhe
    Yuan, Ting-Bi
    Hou, Zong-Yu
    Zhou, Wei-Dong
    Lu, Ji-Dong
    Ding, Hong-Bin
    Zeng, Xiao-Yan
    FRONTIERS OF PHYSICS, 2014, 9 (04) : 419 - 438
  • [34] Chemometrics in laser-induced breakdown spectroscopy
    Zhang, Tianlong
    Tang, Hongsheng
    Li, Hua
    JOURNAL OF CHEMOMETRICS, 2018, 32 (11)
  • [35] Detection of Elemental Composition of Lubricating Grease Using Laser Induced Breakdown Spectroscopy
    Dhiman, Cherry
    Reddy, Martha N.
    Gulati, Kamal
    Khan, Mohd. Shahid
    LUBRICANTS, 2014, 2 (04): : 223 - 236
  • [36] Detection of trace phosphorus in steel using laser-induced breakdown spectroscopy combined with laser-induced fluorescence
    Shen, X. K.
    Wang, H.
    Xie, Z. Q.
    Gao, Y.
    Ling, H.
    Lu, Y. F.
    APPLIED OPTICS, 2009, 48 (13) : 2551 - 2558
  • [37] The effects of oxygen on the detection of mercury using laser-induced breakdown spectroscopy
    Gleason, RL
    Hahn, DW
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (04) : 419 - 430
  • [38] Small-invasive determination of iron content in coating of galvanized steel sheets by laser-induced breakdown spectroscopy
    Lan-xiang Sun
    Wei-ye Wang
    Mei-ting Guo
    Xue-yong Tian
    Peng Zhang
    Li-feng Qi
    Hai-bin Yu
    Peng Zeng
    Journal of Iron and Steel Research International, 2019, 26 : 1137 - 1146
  • [39] Effect of sampling geometry on elemental emissions in laser-induced breakdown spectroscopy
    Multari, RA
    Foster, LE
    Cremers, DA
    Ferris, MJ
    APPLIED SPECTROSCOPY, 1996, 50 (12) : 1483 - 1499
  • [40] Lead of detection in rhododendron leaves using laser-induced breakdown spectroscopy assisted by laser-induced fluorescence
    Zhu, Chenwei
    Tang, Zhiyang
    Li, Qingzhou
    Zhou, Ran
    Lv, Jiaxin
    Zhang, Wen
    Zhan, Kaiping
    Li, Xiangyou
    Zeng, Xiaoyan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 738