The detection of elemental content changes in electrode coating using laser-induced breakdown spectroscopy

被引:0
|
作者
Yang, Lei [1 ]
Li, Yinchuan [1 ]
Pan, Congyuan [2 ]
Bao, Wenyi [1 ]
Qin, Lei [1 ]
Dong, Jingtao [1 ]
Xu, Mengjie [1 ]
Ji, Feng [1 ]
Zhang, Yuzhong [1 ]
Lu, Rongsheng [1 ]
机构
[1] Hefei Univ Technol, Anhui Prov Engn Res Ctr Semicond Inspection Techno, Sch Instrument Sci & Optoelect Engn, Anhui Prov Key Lab Measuring Theory & Precis Instr, Hefei 230009, Anhui, Peoples R China
[2] Anhui Prov Hefei GStar Intelligent Control Tech Co, Hefei 230088, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser-induced breakdown spectroscopy; lithium battery; Electrode coating; Elemental content change; Internal mixed matrix; QUANTITATIVE-ANALYSIS; CATHODE; PERFORMANCE; CALIBRATION; LI; NANOPARTICLES; SPECTROMETRY;
D O I
10.1016/j.sab.2024.106896
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The elemental content of battery electrode coating is prone to change due to the production technology and ambient factors. To ensure the consistent performance and safety of a lithium battery, the elemental content of the electrode coating needs to be kept strictly consistent. This study proposes an internal mixed matrix method that combines laser-induced breakdown spectroscopy and chemometric method to achieve rapid and accurate detection of elemental content changes in electrode coating. The stoichiometric ratios of analytical elements are calculated by using the spectra of laser-induced breakdown spectroscopy. The relationships between that stoichiometric ratios and the actual content of analytical elements are studied and show that they are linear. Thus, the content change of the analytical element can be determined by calculating the change of the stoichiometric ratio. The average relative errors for content changes of iron, lithium, and phosphorus are 6.43%, 2.96%, and 4.12%, respectively, and the lowest detection limits are 278.2 mg/kg, 20.5 mg/kg, and 105.4 mg/kg, respectively. Furthermore, the internal reference method is proposed to correct the effect of ambient gases and improve detection accuracy. The results are that when Fe I 372.751 nm and Fe I 373.485 nm are used as analytical lines, after correcting for the effect of ambient gases, the average relative errors of Fe content changes are reduced by 62% and 72%, respectively, and the lowest detection limits are increased by 67% and 71%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effects of experimental parameters on elemental analysis of coal by laser-induced breakdown spectroscopy
    Li, Jie
    Lu, Jidong
    Lin, Zhaoxiang
    Gong, Shunsheng
    Xie, Chengli
    Chang, Liang
    Yang, Lifei
    Li, Pengyan
    OPTICS AND LASER TECHNOLOGY, 2009, 41 (08) : 907 - 913
  • [22] Improved elemental quantification in copper ores by laser-induced breakdown spectroscopy with judicious data processing
    Velasquez, Marizu
    Alvarez, Jonnathan
    Sandoval, Claudio
    Ramirez, Eimmy
    Bravo, Martin
    Fuentes, Rodrigo
    Myakalwar, Ashwin Kumar
    Castillo, Rosario
    Luarte, Danny
    Sbarbaro, Daniel
    Yanez, Jorge
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 188
  • [23] Trace elemental analysis by laser-induced breakdown spectroscopy-Biological applications
    Kaiser, Jozef
    Novotny, Karel
    Martin, Madhavi Z.
    Hrdlicka, Ales
    Malina, Radomir
    Hartl, Martin
    Adam, Vojtech
    Kizek, Rene
    SURFACE SCIENCE REPORTS, 2012, 67 (11-12) : 233 - 243
  • [24] Laser-induced breakdown spectroscopy for elemental characterization of calcitic alterations on cave walls
    Bassel, Lena
    Motto-Ros, Vincent
    Trichard, Florian
    Pelascini, Frederic
    Ammari, Faten
    Chapoulie, Remy
    Ferrier, Catherine
    Lacanette, Delphine
    Bousquet, Bruno
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (03) : 2197 - 2204
  • [25] Novel Applications of Laser-Induced Breakdown Spectroscopy
    Bauer, Amy J. Ray
    Buckley, Steven G.
    APPLIED SPECTROSCOPY, 2017, 71 (04) : 553 - 566
  • [26] Determination of Chloride Content in Different Types of Cement Using Laser-Induced Breakdown Spectroscopy
    Gondal, M. A.
    Yamani, Z. H.
    Hussain, T.
    Al-Amoudi, O. S. B.
    SPECTROSCOPY LETTERS, 2009, 42 (04) : 171 - 177
  • [27] Application of Laser-Induced Breakdown Spectroscopy in Detection of Cadmium Content in Rice Stems
    Wang, Wei
    Kong, Wenwen
    Shen, Tingting
    Man, Zun
    Zhu, Wenjing
    He, Yong
    Liu, Fei
    Liu, Yufei
    FRONTIERS IN PLANT SCIENCE, 2020, 11
  • [28] An efficient procedure in quantitative analysis using laser-induced breakdown spectroscopy
    Pan, Congyuan
    He, Jiao
    Wang, Guangqian
    Du, Xuewei
    Liu, Yongbin
    Su, Yahui
    PLASMA SCIENCE & TECHNOLOGY, 2019, 21 (03)
  • [29] Laser-induced breakdown spectroscopy detection and classification of biological aerosols
    Hybl, JD
    Lithgow, GA
    Buckley, SG
    APPLIED SPECTROSCOPY, 2003, 57 (10) : 1207 - 1215
  • [30] Determination of elemental impurities in plastic calibration standards using laser-induced breakdown spectroscopy
    Ayyalasomayajula, Krishna K.
    McIntyre, Dustin L.
    Jain, Jinesh
    Singh, Jagdish P.
    Fang Yu-Yueh
    APPLIED OPTICS, 2012, 51 (07) : B143 - B148