Clinical and radiographic results of internal fixation of quadrilateral plate fractures of acetabulum

被引:2
作者
Khamis, Ahmed Refaat [1 ]
Esmat, Emad Eldin [1 ]
Masse, Alessandro [2 ]
Elzeiny, Ahmed [3 ]
Hamed, Hany [3 ]
机构
[1] Benha Univ, Benha Fac Med, Dept Orthopaed & Traumatol, Banha, Egypt
[2] Univ Turin, Ctr Traumatol Ortoped CTO, Dept Orthopaed Surg, Turin, Italy
[3] Kafr El Sheikh Univ, Kafr El Sheikh Fac Med, Dept Orthopaed & Traumatol, Kafr Al Sheikh, Egypt
关键词
Quadrilateral plate; QLP; Acetabular fractures; Suprapectineal infrapectineal plate; STOPPA APPROACH;
D O I
10.1007/s00590-024-04033-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionQuadrilateral plate (QLP) is a relatively thin bony structure located below the pelvic brim proximal to the hip joint, so management of its fractures is challenging.ObjectivesEvaluation of the functional and radiological outcomes of internal fixation of quadrilateral plate acetabular fractures; comparison of two methods of fracture fixation.Patients and methodsA prospective multicentric study including 30 patients who underwent open reduction and internal fixation of QLP fractures through modified Stoppa approach. Patients were divided into two groups according to the method of fixation (anatomical QLP plate vs suprapectineal and infrapectineal plates). Post-operative quality of reduction was evaluated using Matta score. Radiographical assessment according Matta's grading criteria and clinical outcome assessment using the Harris Hip Score (HHS) were repeated at follow-up and at one year to assess displacement.ResultsMean age of patients was 34.9 +/- 12.1 years. After one year follow-up, clinically mean HHS was 88. +/- 5.74. Radiologically post-operative reduction quality was anatomical in 21 (70%) patients, satisfactory in eight (26.7%) patients and unsatisfactory in one (3.3%) patient. Matta's grading at the last follow-up was excellent in 21 (70%) patients, good in six (20%), fair in two (6.7%) patients and poor in one (3.3%) patient. No significant difference was recorded between the two groups in terms of radiographical and clinical results and rate of complications.ConclusionAccurate reduction of quadrilateral plate fracture with secure fixation through modified Stoppa approach provides good and reproducible outcomes with few complications regardless the type of the implant.
引用
收藏
页码:3599 / 3607
页数:9
相关论文
共 50 条
[41]   The pararectus approach for internal fixation of acetabular fractures involving the anterior column: evaluating the functional outcome [J].
von Rueden, Christian ;
Wenzel, Lisa ;
Becker, Johannes ;
Thannheimer, Andreas ;
Augat, Peter ;
Woltmann, Alexander ;
Buehren, Volker ;
Perl, Mario .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) :1487-1493
[42]   Auxiliary cerclage-wiring in internal fixation of displaced acetabular fractures [J].
Erichsen, C. J. ;
von Rueden, C. ;
Hierholzer, C. ;
Buehren, V. ;
Woltmann, A. .
UNFALLCHIRURG, 2015, 118 (01) :35-41
[43]   Morphometric analysis of the anterior column of the acetabulum and safety of intramedullary screw fixation for its fractures in Indian population: a preliminary report [J].
Trikha, Vivek ;
Kumar, Arvind ;
Mittal, Samarth ;
Passey, Jigyasa ;
Gaba, Sahil ;
Kumar, Atin .
INTERNATIONAL ORTHOPAEDICS, 2020, 44 (04) :655-664
[44]   Incidence and clinical relevance of heterotopic ossification after internal fixation of acetabular fractures: retrospective cohort and case control study [J].
Baschera, Dominik ;
Rad, Hooman ;
Collopy, Dermot ;
Zellweger, Rene .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
[45]   Incidence and clinical relevance of heterotopic ossification after internal fixation of acetabular fractures: retrospective cohort and case control study [J].
Dominik Baschera ;
Hooman Rad ;
Dermot Collopy ;
René Zellweger .
Journal of Orthopaedic Surgery and Research, 10
[46]   Morphometric analysis of the anterior column of the acetabulum and safety of intramedullary screw fixation for its fractures in Indian population: a preliminary report [J].
Vivek Trikha ;
Arvind Kumar ;
Samarth Mittal ;
Jigyasa Passey ;
Sahil Gaba ;
Atin Kumar .
International Orthopaedics, 2020, 44 :655-664
[47]   Three-dimensional printing of patient-specific plates for the treatment of acetabular fractures involving quadrilateral plate disruption [J].
Canbin Wang ;
Yuhui Chen ;
Liping Wang ;
Di Wang ;
Cheng Gu ;
Xuezhi Lin ;
Han Liu ;
Jiahui Chen ;
Xiangyuan Wen ;
Yuancheng Liu ;
Fuming Huang ;
Lufeng Yao ;
Shicai Fan ;
Wenhua Huang ;
Jianghui Dong .
BMC Musculoskeletal Disorders, 21
[48]   Inclined angles of acetabular quadrilateral plate: digital measurement and clinical application of the new anatomical concept [J].
Xiaofeng Chen ;
Haiyang Wu ;
Kunming Cheng ;
Ximing Liu ;
Xianhua Cai .
Journal of Orthopaedic Surgery and Research, 18
[49]   Inclined angles of acetabular quadrilateral plate: digital measurement and clinical application of the new anatomical concept [J].
Chen, Xiaofeng ;
Wu, Haiyang ;
Cheng, Kunming ;
Liu, Ximing ;
Cai, Xianhua .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
[50]   Three-dimensional printing of patient-specific plates for the treatment of acetabular fractures involving quadrilateral plate disruption [J].
Wang, Canbin ;
Chen, Yuhui ;
Wang, Liping ;
Wang, Di ;
Gu, Cheng ;
Lin, Xuezhi ;
Liu, Han ;
Chen, Jiahui ;
Wen, Xiangyuan ;
Liu, Yuancheng ;
Huang, Fuming ;
Yao, Lufeng ;
Fan, Shicai ;
Huang, Wenhua ;
Dong, Jianghui .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)