IntroductionQuadrilateral plate (QLP) is a relatively thin bony structure located below the pelvic brim proximal to the hip joint, so management of its fractures is challenging.ObjectivesEvaluation of the functional and radiological outcomes of internal fixation of quadrilateral plate acetabular fractures; comparison of two methods of fracture fixation.Patients and methodsA prospective multicentric study including 30 patients who underwent open reduction and internal fixation of QLP fractures through modified Stoppa approach. Patients were divided into two groups according to the method of fixation (anatomical QLP plate vs suprapectineal and infrapectineal plates). Post-operative quality of reduction was evaluated using Matta score. Radiographical assessment according Matta's grading criteria and clinical outcome assessment using the Harris Hip Score (HHS) were repeated at follow-up and at one year to assess displacement.ResultsMean age of patients was 34.9 +/- 12.1 years. After one year follow-up, clinically mean HHS was 88. +/- 5.74. Radiologically post-operative reduction quality was anatomical in 21 (70%) patients, satisfactory in eight (26.7%) patients and unsatisfactory in one (3.3%) patient. Matta's grading at the last follow-up was excellent in 21 (70%) patients, good in six (20%), fair in two (6.7%) patients and poor in one (3.3%) patient. No significant difference was recorded between the two groups in terms of radiographical and clinical results and rate of complications.ConclusionAccurate reduction of quadrilateral plate fracture with secure fixation through modified Stoppa approach provides good and reproducible outcomes with few complications regardless the type of the implant.
引用
收藏
页码:3599 / 3607
页数:9
相关论文
共 50 条
[21]   Digital anatomical study and clinical application of screw placement for quadrilateral plate fractures in the danger zone [J].
Bei Zhao ;
Zhongye Sun ;
Wei Zhang ;
Zhongbao Xu ;
Xiaofei Yang ;
Weidong Mu .
BMC Musculoskeletal Disorders, 21
[22]   Internal fixation of anterior acetabular fractures with a limited pararectus approach and the anatomical plates: preliminary results [J].
Yao, Sheng ;
Chen, Kaifang ;
Zhu, Fengzhao ;
Liu, Jia ;
Wang, Yulong ;
Zeng, Lian ;
Wan, Yizhou ;
Qu, Yanzhen ;
Yang, Liang ;
Guo, Xiaodong ;
Yang, Xu .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[23]   Internal fixation of anterior acetabular fractures with a limited pararectus approach and the anatomical plates: preliminary results [J].
Sheng Yao ;
Kaifang Chen ;
Fengzhao Zhu ;
Jia Liu ;
Yulong Wang ;
Lian Zeng ;
Yizhou Wan ;
Yanzhen Qu ;
Liang Yang ;
Xiaodong Guo ;
Xu Yang .
BMC Musculoskeletal Disorders, 22
[24]   Fractures of the quadrilateral plate treated with a reconstruction plate and trans-plate quadrilateral screws: An experimental study on cadaveric specimens and finite element analysis [J].
Lan, Shenghui ;
Meng, Chengfei ;
Yuan, Gongwu ;
Wang, Guodong ;
Liu, Ximing ;
Cai, Xianhua .
MEDICINE, 2024, 103 (50) :e40850
[25]   Special contoured pelvic brim reconstruction titanium plate combined with trans-plate buttress screws (quadrilateral screws) for acetabular fractures with quadrilateral plate involvement through the anterior ilioinguinal approach [J].
Wang, Wei ;
Cai, Xianhua ;
Liu, Ximing ;
Wang, Guodong ;
Kang, Hui ;
Qian, Shenglong .
FRONTIERS IN SURGERY, 2024, 11
[26]   Clinical and Radiological Evaluation of Surgically Treated Acetabulum Fractures [J].
Muratoglu, Osman Gorkem ;
Yilmaz, Murat ;
Atlihan, Dogan ;
Yildirim, Cem ;
Muslu, Duran Can ;
Aydin, Mahmud .
DUZCE MEDICAL JOURNAL, 2022, 24 (01) :34-38
[27]   Infrapectineal plating for acetabular fractures: A technical adjunct to internal fixation [J].
Qureshi, AA ;
Archdeacon, MT ;
Jenkins, MA ;
Infante, A ;
DiPasquale, T ;
Bolhofner, BR .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (03) :175-178
[28]   Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation? [J].
Wu, Yong-De ;
Cai, Xian-Hua ;
Liu, Xi-Ming ;
Zhang, Hong-Xi .
CLINICS, 2013, 68 (07) :1028-1033
[29]   Clinical and radiological outcomes of antegrade posterior column screw fixation of the acetabulum [J].
Cavalie, Guillaume ;
Boudissa, Mehdi ;
Kerschbaumer, Gael ;
Seurat, Olivier ;
Ruatti, Sebastien ;
Tonetti, Jerome .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (04)
[30]   Radiographic and clinical evaluation of external pedicle screw fixation as a definitive solution for selective acetabular fractures: a retrospective analysis [J].
Xia, Zhen ;
Zhang, Yazhong ;
Zhang, Xu ;
Li, Wenbo ;
Lv, Yongxiang ;
Qi, Xiangyu ;
Wang, Yunqing ;
Zhu, Ziqiang .
BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)