Clinical and radiographic results of internal fixation of quadrilateral plate fractures of acetabulum

被引:2
|
作者
Khamis, Ahmed Refaat [1 ]
Esmat, Emad Eldin [1 ]
Masse, Alessandro [2 ]
Elzeiny, Ahmed [3 ]
Hamed, Hany [3 ]
机构
[1] Benha Univ, Benha Fac Med, Dept Orthopaed & Traumatol, Banha, Egypt
[2] Univ Turin, Ctr Traumatol Ortoped CTO, Dept Orthopaed Surg, Turin, Italy
[3] Kafr El Sheikh Univ, Kafr El Sheikh Fac Med, Dept Orthopaed & Traumatol, Kafr Al Sheikh, Egypt
关键词
Quadrilateral plate; QLP; Acetabular fractures; Suprapectineal infrapectineal plate; STOPPA APPROACH;
D O I
10.1007/s00590-024-04033-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionQuadrilateral plate (QLP) is a relatively thin bony structure located below the pelvic brim proximal to the hip joint, so management of its fractures is challenging.ObjectivesEvaluation of the functional and radiological outcomes of internal fixation of quadrilateral plate acetabular fractures; comparison of two methods of fracture fixation.Patients and methodsA prospective multicentric study including 30 patients who underwent open reduction and internal fixation of QLP fractures through modified Stoppa approach. Patients were divided into two groups according to the method of fixation (anatomical QLP plate vs suprapectineal and infrapectineal plates). Post-operative quality of reduction was evaluated using Matta score. Radiographical assessment according Matta's grading criteria and clinical outcome assessment using the Harris Hip Score (HHS) were repeated at follow-up and at one year to assess displacement.ResultsMean age of patients was 34.9 +/- 12.1 years. After one year follow-up, clinically mean HHS was 88. +/- 5.74. Radiologically post-operative reduction quality was anatomical in 21 (70%) patients, satisfactory in eight (26.7%) patients and unsatisfactory in one (3.3%) patient. Matta's grading at the last follow-up was excellent in 21 (70%) patients, good in six (20%), fair in two (6.7%) patients and poor in one (3.3%) patient. No significant difference was recorded between the two groups in terms of radiographical and clinical results and rate of complications.ConclusionAccurate reduction of quadrilateral plate fracture with secure fixation through modified Stoppa approach provides good and reproducible outcomes with few complications regardless the type of the implant.
引用
收藏
页码:3599 / 3607
页数:9
相关论文
共 50 条
  • [1] Quadrilateral plate fractures of the acetabulum: An update
    White, Grace
    Kanakaris, Nikolaos K.
    Faour, Omar
    Antonio Valverde, Jose
    Angel Martin, Miguel
    Giannoudis, Peter V.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (02): : 159 - 167
  • [2] Fixation of quadrilateral plate fractures of the acetabulum using the buttress screw: A novel technique
    Karim, Mahmoud Abdel
    Abdelazeem, Ahmed Hazem
    Youness, Mohamed
    El Nahal, Walid A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (08): : 1813 - 1818
  • [3] Internal fixation of osteopenic acetabular fractures involving the quadrilateral plate
    Laflamme, G. Y.
    Hebert-Davies, J.
    Rouleau, D.
    Benoit, B.
    Leduc, S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (10): : 1130 - 1134
  • [4] Cerclage Wire-Plate Composite for Fixation of Quadrilateral Plate Fractures of the Acetabulum: A Checkrein and Pulley Technique
    Farid, Yasser R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (05) : 323 - 328
  • [5] OPEN REDUCTION AND INTERNAL-FIXATION OF FRACTURES OF THE ACETABULUM - RESULTS IN 163 FRACTURES
    MAYO, KA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (305) : 31 - 37
  • [6] A new internal fixation technique for acetabular fractures involving the quadrilateral plate
    Zha, Guo-Chun
    Tulumuhan, Du-Man
    Wang, Tao
    Wan, Guo-Yang
    Wang, Yong
    Sun, Jun-Ying
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (05) : 855 - 861
  • [7] Quadrilateral plate fractures of the acetabulum: Proposition for a novel classification system
    ElNahal, Walid A.
    Karim, Mahmoud Abdel
    Khaled, Sherif A.
    Abdelazeem, Ahmed Hazem
    Abdelazeem, Hazem
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (02): : 296 - 301
  • [8] Use of calcaneal locking plate in surgical treatment of quadrilateral plate fractures of the acetabulum
    Ahmadi M.A.
    Moein S.A.
    Fereidooni R.
    Ayatizadeh S.H.
    MUSCULOSKELETAL SURGERY, 2024, 108 (4) : 431 - 436
  • [9] Finite element analysis of the stability of combined plate internal fixation in posterior wall fractures of acetabulum
    Liu, Xi-Ming
    Pan, Chang-Wu
    Wang, Guo-Dong
    Cai, Xian-Hua
    Chen, Lei
    Meng, Cheng-Fei
    Huang, Jin-Cheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13393 - 13397
  • [10] Comparison of Radiographic and Clinical Results between MIPO Internal Fixation and Auxiliary Tension Suture Fixation for Proximal Humeral Fractures
    Yu, X.
    Zhang, H.
    Xu, R. J.
    Huang, A. Q.
    Yu, Z. H.
    Miao, Y.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 82 : 109 - 114