Design and Development of a Non-invasive Opto-Electronic Sensor for Blood Glucose Monitoring Using a Visible Light Source

被引:0
作者
Alam, Iftekar [1 ]
Dunde, Anjaneyulu [2 ]
Balapala, Kartheek R. [3 ]
Gangopadhyay, Moumita [4 ]
Dewanjee, Saikat [5 ]
Mukherjee, Moutima [1 ]
机构
[1] Adamas Univ, Dept Med Phys, Kolkata, India
[2] Baptist Med Ctr South, Dept Internal Med, Montgomery, AL USA
[3] Copperbelt Univ, Michael Chilufya Sata Sch Med, Dept Physiol, Kitwe, Zambia
[4] Adamas Univ, Dept Biotechnol, Kolkata, India
[5] Jadavpur Univ, Dept Pharmaceut Technol, Kolkata, India
关键词
patient compliance in diabetes care; commercially viable medical devices; optical glucose sensing; glucose concentration detection; physiological variability; infrared spectroscopy; blood glucose measurement; laser light refraction; diabetes management; non-invasive glucose monitoring; HYPERGLYCEMIA;
D O I
10.7759/cureus.60745
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The management of diabetes is critically dependent on the continuous monitoring of blood glucose levels. Contemporary approaches primarily utilize invasive methods, which often prove to be uncomfortable and can deter patient adherence. There is a pressing need for the development of novel strategies that improve patient compliance and simplify the process of glucose monitoring. Aim and objectives The primary objective of this research is to develop a non-invasive blood glucose monitoring system (NIBGMS) that offers a convenient alternative to conventional invasive methods. This study aims to demonstrate the feasibility and accuracy of using visible laser light at a wavelength of 650 nm for glucose monitoring and to address physiological and technical challenges associated with in vivo measurements. Methods Our approach involved the design of a device that exploits the quantitative relationship between glucose concentration and the refraction phenomena of laser light. The system was initially calibrated and tested using glucose solutions across a range of concentrations (25-500 mg/dL). To get around the problems that come up when people's skin and bodies are different, we combined an infrared (IR) transmitter (800 nm) and receiver that checks for changes in voltage, which are indicative of glucose levels. Results The prototype device was compared with a commercially available blood glucose monitor (Accu-Chek active machine; Roche Diabetes Care, Inc., Mumbai, India). The results demonstrated an average linearity of 95.7% relative to the Accu-Chek machine, indicating a high level of accuracy in the non-invasive measurement of glucose levels. Conclusions The findings suggest that our NIBGMS holds significant promise for clinical application. It reduces the discomfort associated with blood sampling and provides reliable measurements that are comparable to those of existing invasive methods. The successful development of this device paves the way for further commercial translation and could significantly improve the quality of life for individuals with diabetes, by facilitating easier and more frequent monitoring.
引用
收藏
页数:13
相关论文
共 29 条
[1]   Recent advances in optical sensors for continuous glucose monitoring [J].
Ahmed, Israr ;
Jiang, Nan ;
Shao, Xinge ;
Elsherif, Mohamed ;
Alam, Fahad ;
Salih, Ahmed ;
Butt, Haider ;
Yetisen, Ali K. .
SENSORS & DIAGNOSTICS, 2022, 1 (06) :1098-1125
[2]  
Andersen Jan-Hugo, 2019, J Electr Bioimpedance, V10, P133, DOI 10.2478/joeb-2019-0019
[3]   Highly integrated watch for noninvasive continual glucose monitoring [J].
Chang, Tianrui ;
Li, Hu ;
Zhang, Nianrong ;
Jiang, Xinran ;
Yu, Xinge ;
Yang, Qingde ;
Jin, Zhiyuan ;
Meng, Hua ;
Chang, Lingqian .
MICROSYSTEMS & NANOENGINEERING, 2022, 8 (01)
[4]   Plant-Based Antidiabetic Nanoformulations: The Emerging Paradigm for Effective Therapy [J].
Dewanjee, Saikat ;
Chakraborty, Pratik ;
Mukherjee, Biswajit ;
De Feo, Vincenzo .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (06)
[5]   Very Selective Detection of Low Physiopathological Glucose Levels by Spontaneous Raman Spectroscopy with Univariate Data Analysis [J].
Golparvar, Ata ;
Boukhayma, Assim ;
Loayza, Timothy ;
Caizzone, Antonino ;
Enz, Christian ;
Carrara, Sandro .
BIONANOSCIENCE, 2021, 11 (03) :871-877
[6]   RETRACTED: Sulphonylurea monotherapy for patients with type 2 diabetes mellitus (Retracted Article) [J].
Hemmingsen, Bianca ;
Schroll, Jeppe B. ;
Lund, Soren S. ;
Wetterslev, Jorn ;
Gluud, Christian ;
Vaag, Allan ;
Sonne, David Peick ;
Lundstrom, Lars H. ;
Almdal, Thomas .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (04)
[7]   Noninvasive Blood Glucose Monitoring Systems Using Near-Infrared Technology-A Review [J].
Hina, Aminah ;
Saadeh, Wala .
SENSORS, 2022, 22 (13)
[8]   Diabetic Complications and Oxidative Stress: A 20-Year Voyage Back in Time and Back to the Future [J].
Iacobini, Carla ;
Vitale, Martina ;
Pesce, Carlo ;
Pugliese, Giuseppe ;
Menini, Stefano .
ANTIOXIDANTS, 2021, 10 (05)
[9]   Update on the treatment of type 2 diabetes mellitus [J].
Jose Marin-Penalver, Juan ;
Martin-Timon, Iciar ;
Sevillano-Collantes, Cristina ;
Javier del Canizo-Gomez, Francisco .
WORLD JOURNAL OF DIABETES, 2016, 7 (17) :354-395
[10]   Wearable non-invasive epidermal glucose sensors: A review [J].
Kim, Jayoung ;
Campbell, Alan S. ;
Wang, Joseph .
TALANTA, 2018, 177 :163-170