Investigational Study of Mesalamine Dissolution Discrepancy: Utilization of Hyphenated Ultrahigh Performance Liquid Chromatography-Charged Aerosol Detection-High-Resolution Mass Spectrometry

被引:1
作者
Kumar, Sumit [1 ]
Vakkala, Sudhakar [2 ]
Ganesan, Thipashini [3 ]
Batna, Ravibabu [4 ]
See, Hong Heng [3 ]
Allada, Ravikiran [3 ]
Shah, Ravi P. [1 ]
机构
[1] Natl Inst Pharmaceut Educ & Res NIPER, Dept Pharmaceut Anal, Ahmadabad, India
[2] KL Deemed be Univ, Dept Chem, Vijayawada, India
[3] Univ Teknol Malaysia, Ibnu Sina Inst Sci & Ind Res, Ctr Sustainable Nanomat, Johor Baharu, Johor, Malaysia
[4] Univ Malaysia Terengganu, Dept Chem, Kuala Terengganu, Terengganu, Malaysia
来源
SEPARATION SCIENCE PLUS | 2024年 / 7卷 / 08期
关键词
artifacts; high-resolution mass spectrometry; hydrogen-deuterium exchange; inverse liquid chromatography-charged aerosol detector gradient; mesalamine; IMPURITIES; MESALAZINE;
D O I
10.1002/sscp.202400094
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pentasa (mesalamine/MSLM) is a widely prescribed delayed-release capsule formulation for the treatment of inflammatory bowel disease. During dissolution study of Pentasa through ultraviolet (UV) spectroscopy, an unusual end-release of about 110% has been observed. Initial liquid chromatography-UV (LC-UV) analyses of these dissolution samples confirmed three prominent peaks other than MSLM with a significant area percentage. Further systematic investigation was carried out by incubating active pharmaceutical ingredient in dissolution media for a longer duration and at elevated temperature followed by analysis through an inverse gradient LC-charged aerosol detector (CAD). LC-high-resolution mass spectrometry (HRMS) and online hydrogen-deuterium exchange (HDX) mass spectrometry were also employed to identify and characterize these artifact products. The area % of prominent artifacts in LC-UV was found to be way significant when compared to the area % obtained through inverse LC-CAD, as CAD quantifies the peaks independent of the UV wavelength of absorbance. Inverse LC-CAD was suitable to determine the relative response factor, whereas LC-HRMS/MS and online HDX-MS supported the characterization of these artifacts. These artifacts were found to be trimers, tetramers of MSLM formed due to polymerization, imparting additional pi-bonds resulting in high UV absorptivity. These techniques when used in combinations serve complimentary to each other during such investigations.
引用
收藏
页数:8
相关论文
共 24 条
  • [21] Hyphenated liquid chromatography-diode array detection-charged aerosol detection-high resolution-multistage mass spectrometry with online hydrogen/deuterium exchange: One stop solution for pharmaceutical impurity profiling
    Thakkar, Harsh
    Jain, Sonali
    Kumar, Sumit
    Bhalekar, Vijay S.
    Gangakhedkar, Shriya
    Shah, Ravi P.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2023, 1689
  • [22] Exploration of the effects of chloride ions on the analysis of polar compounds at low concentrations by hydrophilic interaction liquid chromatography coupled to a charged aerosol detector: Application to tromethamine
    Toussaint, Balthazar
    Immame Hassane Beck, Taslyne
    Surget, Estelle
    Boudy, Vincent
    Jaccoulet, Emmanuel
    [J]. JOURNAL OF SEPARATION SCIENCE, 2023, 46 (06)
  • [23] Wu L., 2024, J SEP SCI, V47
  • [24] Advances in orally-delivered pH-sensitive nanocarrier systems; an optimistic approach for the treatment of inflammatory bowel disease
    Zeeshan, Mahira
    Ali, Hussain
    Khan, Salman
    Khan, Saeed Ahmad
    Weigmann, Benno
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 558 : 201 - 214