Escherichia coli -polydopamine coated stir bar sorptive extraction combing with portable mass spectrometer for rapid and simultaneous detection of triphenylmethane residues in fishes

被引:1
|
作者
Cao, Jingya [1 ]
Liu, Bailu [1 ]
Tao, Zhihao [1 ]
Liu, Fubang [1 ]
Liu, Qilin [1 ]
Li, Tianhua [1 ]
Wen, Luhong [2 ,3 ]
Gan, Ning [1 ]
机构
[1] Ningbo Univ, Inst Mass Spectrometry, Sch Mat Sci & Chem Engn, Key Lab Adv Mass Spectrometry & Mol Anal Zhejiang, Ningbo 315211, Zhejiang, Peoples R China
[2] Ningbo Univ, Res Inst Adv Technol, Ningbo 315211, Zhejiang, Peoples R China
[3] China Innovat Instrument Co Ltd, Ningbo 315000, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
PDMS@PDA@ E. coli coated stir bar; Portable spectrometer; Triphenylmethane residues; On-site detection; Aquaculture products; PERFORMANCE LIQUID-CHROMATOGRAPHY; MALACHITE GREEN; CRYSTAL VIOLET; LEUCOMALACHITE GREEN; SURFACE-CHEMISTRY; GENTIAN-VIOLET; METABOLITES;
D O I
10.1016/j.microc.2024.110771
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid, accurate, and simultaneous detection of triphenylmethane (TPM) residues and their metabolites in aquaculture products is vital to ensure the safety of aquatic products. In this study, a novel Escherichia coli ( E. coli ) engineering bacteria-polydopamine (PDMS@PDA@ E. coli ) coated stir bar was prepared for the extraction and enrichment of malachite green (MG), leucomalachite green (LMG), crystal violet (CV), and leucocrystal violet (LCV), which are typical TPM drugs utilised in aquaculture. A PDMS stir bar was first modulated to show hydrophilic properties via plasma treatment to enhance the evenness and stability of PDA coating. Subsequently, the PDMS@PDA stir bar was adsorbed with E. coli to form PDMS@PDA@ E. coli coating, which showed enhanced extraction capacity and selectivity towards TPMs. These characteristics were due to the specific adsorption properties of TPM dyes by Gram -negative bacteria. A hand -held stirring device was installed with the stir bar for on-site extraction. To directly detect the eluted targets without separation, a portable mass spectrometer was utilised. Under the optimal conditions, the samples can be rapidly pretreated (within 30 min) and used for the analysis of 4 TPMs with a recovery of 77.8 %-97.0 % together with the detection limits of 0.13 -0.38 mu g/kg. These findings prove that the assay has potential application value and broad prospects for the on-site detection of TPM residues in fish.
引用
收藏
页数:8
相关论文
共 3 条
  • [1] Combining portable mass spectrometer with bamboo stir bar sorptive extraction for the on-site detection of malachite green, crystal violet and their metabolites in fishes
    Shen, Yuxia
    Xiong, Wei
    Wang, Qiqin
    Zhang, Wentian
    Xie, Hongzhen
    Cao, Yuting
    Xu, Qing
    Wen, Luhong
    Gan, Ning
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1681
  • [2] Robust polydimethylsiloxane-polydopamine coated stir bar for rapid extraction of malachite green, crystal violet and their metabolites in aquatic waters and determined by portable mass spectrometry
    Cao, Jinya
    Shen, Yuxia
    Liu, Zhaixin
    Zhu, Shanshan
    Wu, Huihui
    Dang, Yali
    Li, Tianhua
    Gan, Ning
    JOURNAL OF CHROMATOGRAPHY OPEN, 2024, 5
  • [3] Simultaneous determination of various heavy metal and arsenic ions in seafood using functionalized fibrous silica (KCC-1) coated stir bar sorptive extraction prior to inductively coupled plasma mass spectrometry
    Song, Gongshuai
    Guo, Xichuang
    Li, Qianyun
    Liao, Jie
    Wang, Danli
    Yuan, Tinglan
    Li, Ling
    Fang, Ruosi
    Zhang, Mengna
    Shen, Qing
    Zheng, Fuping
    Gong, Jinyan
    FOOD CONTROL, 2023, 152