Studies on seismic performance of CFRP and steel bars hybrid reinforced concrete frames

被引:4
作者
Li, Xiaopeng [1 ]
Yin, Lu [1 ]
Zhao, Jun [3 ]
Jiang, Yibo [2 ]
机构
[1] Zhengzhou Univ, Sch Civil Engn, Zhengzhou 450001, Peoples R China
[2] Zhengzhou Univ, Sch Mech & Safety Engn, Zhengzhou 450001, Peoples R China
[3] North China Univ Water Resources & Elect Power, Sch Civil Engn & Transportat, Zhengzhou 450045, Peoples R China
关键词
Carbon fibre reinforced polymer bar; Concrete frame; Seismic performance; CFRP bar replacement ratios; Calculation method of load carrying capacity; COLUMNS; BEHAVIOR;
D O I
10.1016/j.istruc.2024.106545
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The studies investigated the seismic performance of carbon fibre-reinforced polymer (CFRP) and steel bars hybrid reinforced concrete (CSRC) frames. The influences of CFRP bar replacement ratios (CBRRs) and positions (CBRPs) in the frame columns were studied. Pseudo-static tests were conducted on four frame specimens. One basic specimen was a reinforced concrete (RC) frame. The other three were CSRC frames with 23.37%, 46.75% and 58.44% of CBRRs. The test results showed the CSRC frame specimens presented remained in the failure mode of strong column-weak beam as the basic RC frame specimen. Compared with the RC frame, the maximum load carrying capacity changed negligibly, but the peak displacements significantly increased by 19.42% to 59.37%, as the CBRRs increased from 23.37% to 58.44%. The ductility, residual displacement, initial lateral stiffness and cumulative energy dissipation of CSRC frames had no obvious change as the CBRRs were less than 26.47%. As the CBRRs were larger than 46.75%, the residual drift ratios of the CSRC frames decreased by 15.22% to 20.13% at 2.00% rift ratio level, the cumulative energy dissipations of the CSRC frames decreased by 9.69-15.42% at 3.00% rift ratio level, Compared with the RC specimen. Finally, the calculation models for calculating the load carrying capacity of CSRC frames and columns were proposed. The calculated results and test results were in good agreement.
引用
收藏
页数:17
相关论文
共 53 条
[1]  
AIJ, AIJ-1990
[2]   Experimental and numerical analysis of CFRP-concrete joint bond behavior after exposure to wet-dry cycles [J].
Al-Lami, Karrar ;
Colombi, Pierluigi ;
D'Antino, Tommaso .
COMPOSITE STRUCTURES, 2023, 303
[3]  
[Anonymous], 2005, EUROCODE 8 DESIGN ST
[4]  
[Anonymous], 2011, Standard JGJ 55-2011
[5]  
[Anonymous], 2019, GB/T 50081-2019
[6]  
[Anonymous], 2008, 318 ACI
[7]  
[Anonymous], 2010, Standard for design of concrete structures
[8]   Effects of FRP bar type and fiber reinforced concrete on the flexural behavior of hybrid beams [J].
Aydin, Emine ;
Boru, Elif ;
Aydin, Ferhat .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 279
[9]   Experimental investigation of thermal expansion and concrete strength effects on FRP bars behavior embedded in concrete [J].
Aydin, Ferhat .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 163 :1-8
[10]  
Bazant ZP, 1997, J ENG MECH, V123, P162