Evaluation of the QMAC-dRAST System Version 2.5 for Rapid Antimicrobial Susceptibility Testing of Gram-Negative Bacteria From Positive Blood Culture Broth and Subcultured Colony Isolates

被引:2
|
作者
Kim, Tae Yeul [1 ]
Kang, Minhee [2 ,3 ]
Shim, Hyang Jin [4 ]
Kang, On-Kyun [1 ]
Huh, Hee Jae [1 ,3 ]
Lee, Nam Yong [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Lab Med & Genet, Seoul, South Korea
[2] Samsung Med Ctr, Smart Healthcare Res Inst, Biomed Engn Res Ctr, Seoul, South Korea
[3] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol, Dept Med Device Management & Res, Seoul, South Korea
[4] Samsung Med Ctr, Samsung Biomed Res Inst, Ctr Clin Med, Seoul, South Korea
关键词
antimicrobial resistance; antimicrobial susceptibility testing; bloodstream infections; broth microdilution; Gram-negative; positive blood culture broth; QMAC-dRAST; VITEK; 2; TURNAROUND TIME; VITEK-2; SYSTEM; IDENTIFICATION; ENTEROBACTERIACEAE; MORTALITY;
D O I
10.1002/jcla.25043
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Rapid antimicrobial susceptibility testing (AST) for bloodstream infections (BSIs) facilitates the optimization of antimicrobial therapy, preventing antimicrobial resistance and improving patient outcomes. QMAC-dRAST (QuantaMatrix Inc., Korea) is a rapid AST platform based on microfluidic chip technology that performs AST directly using positive blood culture broth (PBCB). This study evaluated the performance of QMAC-dRAST for Gram-negative bacteria using PBCB and subcultured colony isolates, comparing it with that of VITEK 2 (bioM & eacute;rieux, France) using broth microdilution (BMD) as the reference method. Methods We included 141 Gram-negative blood culture isolates from patients with BSI and 12 carbapenemase-producing clinical isolates of Enterobacterales spiked into blood culture bottles. QMAC-dRAST performance was evaluated using PBCB and colony isolates, whereas VITEK 2 and BMD were tested only on colony isolates. Results For PBCB, QMAC-dRAST achieved 92.1% categorical agreement (CA), 95.3% essential agreement (EA), with 1.8% very major errors (VMEs), 3.5% major errors (MEs), and 5.2% minor errors (mEs). With colony isolates, it exhibited 92.5% CA and 95.1% EA, with 2.0% VMEs, 3.2% MEs, and 4.8% mEs. VITEK 2 showed 94.1% CA and 96.0% EA, with 4.3% VMEs, 0.4% MEs, and 4.3% mEs. QMAC-dRAST yielded elevated error rates for specific antimicrobial agents, with high VMEs for carbapenems and aminoglycosides. The median time to result for QMAC-dRAST was 5.9 h for PBCB samples and 6.1 h for subcultured colony isolates. Conclusions The QMAC-dRAST system demonstrated considerable strengths and comparable performance to the VITEK 2 system; however, challenges were discerned with specific antimicrobial agents, underlining a necessity for improvement.
引用
收藏
页数:9
相关论文
共 48 条
  • [11] Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
    Kavipriya, D.
    Prakash, Suman Susan
    Dhandapani, Sarumathi
    Rajshekar, Deepashree
    Sastry, Apurba Sankar
    JOURNAL OF LABORATORY PHYSICIANS, 2021, 13 (04) : 374 - 379
  • [12] Identification and antimicrobial susceptibility testing of Gram-positive and Gram-negative bacteria from positive blood cultures using the Accelerate Pheno™ system
    Ullberg, Mans
    Ozenci, Volkan
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (01) : 139 - 149
  • [13] Evaluation of the Vitek® Reveal™ system for rapid antimicrobial susceptibility testing of Gram-negative pathogens, including ESBL, CRE and CRAB, from positive blood cultures
    Antonelli, Alberto
    Cuffari, Sara
    Casciato, Benedetta
    Giani, Tommaso
    Rossolini, Gian Maria
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 110 (04)
  • [14] Evaluation of Direct Antimicrobial Susceptibility Testing of Gram-Negative Bacilli and Staphylococcus aureus from Positive Pediatric Blood Culture Bottles Using BD Phoenix M50
    Morales, Princess
    Tang, Patrick
    Mariano, Elaine
    Gopalan, Arun
    Aji, Nisha
    Perez-Lopez, Andres
    Suleiman, Mohammed
    MICROORGANISMS, 2024, 12 (08)
  • [15] Verification of the Vitek Reveal System for Direct Antimicrobial Susceptibility Testing in Gram-Negative Positive Blood Cultures
    Menchinelli, Giulia
    Squitieri, Damiano
    Magri, Carlotta
    De Maio, Flavio
    D'Inzeo, Tiziana
    Cacaci, Margherita
    De Angelis, Giulia
    Sanguinetti, Maurizio
    Posteraro, Brunella
    ANTIBIOTICS-BASEL, 2024, 13 (11):
  • [16] Rapid identification and antimicrobial susceptibility testing of Gram-negative rod on positive blood cultures using MicroScan panels
    Infante, A.
    de la Tabla, V. Ortiz
    Martin, C.
    Gazquez, G.
    Bunuel, F.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2021, 40 (01) : 151 - 157
  • [17] Comparative evaluation of the Vitek-2 Compact and Phoenix systems for rapid identification and antibiotic susceptibility testing directly from blood cultures of Gram-negative and Gram-positive isolates
    Gherardi, Giovanni
    Angeletti, Silvia
    Panitti, Miriam
    Pompilio, Arianna
    Di Bonaventura, Giovanni
    Crea, Francesca
    Avola, Alessandra
    Fico, Laura
    Palazzo, Carlo
    Sapia, Genoveffa Francesca
    Visaggio, Daniela
    Dicuonzo, Giordano
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 72 (01) : 20 - 31
  • [18] Evaluation of an automated rapid phenotypic antimicrobial susceptibility testing (ASTar, Q-linea AB) applied directly on blood cultures bottles positive for Gram-negative pathogens
    Banchini, Isabella
    Borgatti, Eva Caterina
    Foschi, Claudio
    Lazzarotto, Tiziana
    Ambretti, Simone
    NEW MICROBIOLOGICA, 2024, 47 (01) : 107 - 110
  • [19] Evaluation of three protocols for direct susceptibility testing for Gram-negative rods from flagged positive blood culture bottles
    Khan, Salman
    Das, Arghya
    Mishra, Anwita
    Vidyarthi, Ashima Jain
    Nandal, Mukesh
    Yadav, Himanshu
    Roy, Shayak
    Singh, Mahipal
    MICROBIOLOGY SPECTRUM, 2024, 12 (04):
  • [20] Rapid identification and antimicrobial susceptibility testing of Gram-negative rod on positive blood cultures using MicroScan panels
    A. Infante
    V. Ortiz de la Tabla
    C. Martín
    G. Gázquez
    F. Buñuel
    European Journal of Clinical Microbiology & Infectious Diseases, 2021, 40 : 151 - 157