Evaluation of calibration performance of a low-cost particulate matter sensor using collocated and distant NO2

被引:2
|
作者
Ko, Kabseok [1 ]
Cho, Seokheon [2 ]
Rao, Ramesh R. [2 ]
机构
[1] Kangwon Natl Univ, Dept Elect Engn, Chunchon 24341, South Korea
[2] Univ Calif San Diego UCSD, Qualcomm Inst, La Jolla, CA 92093 USA
基金
新加坡国家研究基金会;
关键词
LABORATORY EVALUATION; AMBIENT CONDITIONS; FIELD-EVALUATION; AIR-POLLUTION; NETWORK; PM2.5;
D O I
10.5194/amt-17-3303-2024
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Low-cost optical particle sensors have the potential to supplement existing particulate matter (PM) monitoring systems and to provide high spatial and temporal resolutions. However, low-cost PM sensors have often shown questionable performance under various ambient conditions. Temperature, relative humidity (RH), and particle composition have been identified as factors that directly affect the performance of low-cost PM sensors. This study investigated whether NO2 , which creates PM2.5 by means of chemical reactions in the atmosphere, can be used to improve the calibration performance of low-cost PM2.5 sensors. To this end, we evaluated the PurpleAir PA-II, called PA-II, a popular air monitoring system that utilizes two low-cost PM sensors and that is frequently deployed near air quality monitoring sites of the Environmental Protection Agency (EPA). We selected a single location where 14 PA-II units have operated for more than 2 years, since July 2017. Based on the operating periods of the PA-II units, we then chose the period of January 2018 to December 2019 for study. Among the 14 units, a single unit containing more than 23 months of measurement data with a high correlation between the unit's two PMS sensors was selected for analysis. Daily and hourly PM2.5 measurement data from the PA-II unit and a BAM 1020 instrument, respectively, were compared using the federal reference method (FRM), and a per-month analysis was conducted against the BAM-1020 using hourly PM2.5 data. In the per-month analysis, three key features - namely temperature, relative humidity (RH), and NO2 - were considered. The NO2 , called collocated NO2 , was collected from the reliable instrument collocated with the PA-II unit. The per-month analysis showed that the PA-II unit had a good correlation (coefficient of determination R-2 > 0.819 ) with the BAM-1020 during the months of November, December, and January in both 2018 and 2019, but their correlation intensity was moderate during other months, such as in July and September 2018 and August, September, and October 2019. NO2 was shown to be a key factor in increasing the value of R-2 in the months when moderate correlation based on only PM2.5 was achieved. This study calibrated a PA-II unit using multiple linear regression (MLR) and random forest (RF) methods based on the same three features used in the analysis studies, as well as their multiplicative terms. The addition of NO2 had a much larger effect than that of RH when both PM2.5 and temperature were considered for calibration in both models. When NO2 , temperature, and relative humidity were considered, the MLR method achieved similar calibration performance to the RF method. In addressing the feasibility of utilizing distant NO2 measurements for calibration in lieu of collocated data, the study highlights the effectiveness of distant NO2 when correlated strongly with collocated measurements. This finding offers a practical solution for situations where obtaining collocated NO2 data proves to be challenging or costly. We assessed the performance of different PA-II units to determine their efficacy. Our investigation reveals a significant enhancement in calibration performance across different PA-II units upon integrating NO2 . Importantly, this improvement remains consistent even when employing models trained with different PA-II units within the same location. Overall, this investigation emphasizes the significance of NO2 in improving calibration for low-cost PM 2.5 sensors and presents insights into leveraging distant NO2 measurements as a viable alternative for calibration in the absence of collocated data.
引用
收藏
页码:3303 / 3322
页数:20
相关论文
共 50 条
  • [31] Using a Low-Cost Sensor to Estimate Fine Particulate Matter: A Case Study in Samutprakarn, Thailand
    Roddee, Supichaya
    Changphuek, Supachai
    Jirakajohnkool, Supet
    Tochaiyaphum, Panatda
    Phairuang, Worradorn
    Chetiyanukornkul, Thaneeya
    Boongla, Yaowatat
    ATMOSPHERE, 2024, 15 (03)
  • [32] Low-Cost Formaldehyde Sensor Evaluation and Calibration in a Controlled Environment
    Chattopadhyay, Arnab
    Huertas, Andres
    Rebeiro-Hargrave, Andrew
    Fung, Pak Lun
    Varjonen, Samu
    Hieta, Tuomas
    Tarkoma, Sasu
    Petaja, Tuukka
    IEEE SENSORS JOURNAL, 2022, 22 (12) : 11791 - 11802
  • [33] Data Evaluation of a Low-Cost Sensor Network for Atmospheric Particulate Matter Monitoring in 15 Municipalities in Serbia
    Stojanovic, Danka B.
    Kleut, Duska
    Davidovic, Milos
    Zivkovic, Marija
    Ramadani, Uzahir
    Jovanovic, Maja
    Lazovic, Ivan
    Jovasevic-Stojanovic, Milena
    SENSORS, 2024, 24 (13)
  • [34] Calibration of CO, NO2, and O3 Using Airify: A Low-Cost Sensor Cluster for Air Quality Monitoring
    Ionascu, Marian-Emanuel
    Castell, Nuria
    Boncalo, Oana
    Schneider, Philipp
    Darie, Marius
    Marcu, Marius
    SENSORS, 2021, 21 (23)
  • [35] Laboratory and field evaluation of three low-cost particulate matter sensors
    Ghamari, Mohammad
    Soltanpur, Cinna
    Rangel, Pablo
    Groves, William A.
    Kecojevic, Vladislav
    IET WIRELESS SENSOR SYSTEMS, 2022, 12 (01) : 21 - 32
  • [36] Evaluation of Low-Cost Particulate Matter (PM) Sensors: A Preliminary Investigation
    Qian, Defeng
    Pang, Zhihong
    O'Neill, Zheng
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [37] Spatiotemporal distribution of indoor particulate matter concentration with a low-cost sensor network
    Li, Jiayu
    Li, Haoran
    Ma, Yehan
    Wang, Yang
    Abokifa, Ahmed A.
    Lu, Chenyang
    Biswas, Pratim
    BUILDING AND ENVIRONMENT, 2018, 127 : 138 - 147
  • [38] Feasibility of low-cost particulate matter sensors for long-term environmental monitoring: Field evaluation and calibration
    Feng Z.
    Zheng L.
    Ren B.
    Liu D.
    Huang J.
    Xue N.
    Science of the Total Environment, 2024, 945
  • [39] Benchmarking Low-Cost Particulate Matter Sensors: Evaluating Performance Under Controlled Environmental Conditions Using Low-Cost Experimental Setups
    Cruz, Arianna Alvarez
    Schalm, Olivier
    Hernandez, Luis Ernesto Morera
    Laguardia, Alain Martinez
    Sanchez, Daniellys Alejo
    Perez, Mayra C. Morales
    Rivero, Rosa Amalia Gonzalez
    Gomez, Yasser Morera
    ATMOSPHERE, 2025, 16 (02)
  • [40] Calibration of a Low-Cost Methane Sensor Using Machine Learning
    Mitchell, Hazel Louise
    Cox, Simon J.
    Lewis, Hugh G.
    SENSORS, 2024, 24 (04)