Optimizing inferior vena cava filter design: A computational fluid dynamics study on strut configuration for enhanced hemodynamic performance and thrombosis reduction

被引:2
作者
Kim, Byeong-Jun [1 ]
Lee, Chiseung [2 ,3 ]
机构
[1] Pusan Natl Univ, Grad Sch, Dept Biomed Engn, Busan 49241, South Korea
[2] Pusan Natl Univ, Sch Med, Dept Biomed Engn, Busan 49241, South Korea
[3] Pusan Natl Univ Hosp, Biomed Res Inst, Busan 49241, South Korea
关键词
Computer modeling and simulation; In silico medicine; Inferior vena cava filter; Filter optimization; Blood clot treatment; Computational fluid dynamics; BLOOD-FLOW; PULMONARY-EMBOLISM; VEIN-THROMBOSIS; MODELS;
D O I
10.1016/j.heliyon.2024.e32667
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and objective: Inferior vena cava filters have been shown to be effective in preventing deep vein thrombosis and its secondary complication, pulmonary embolism, thereby reducing the high mortality rate. Although inferior vena cava filters have evolved, specific complications like inferior vena cava thrombosis -induced deep vein thrombosis worsening and recurrent pulmonary embolism continue to pose challenges. This study analyzes the effects of geometric parameter variations of inferior vena cava filters, which have a significant impact on the thrombus formation inside the filter, the capture, dissolution, and hemodynamic flow of thrombus, as well as the shear stress on the filter and vascular wall. Methods: This study used computational fluid dynamic simulations with the carreau model to investigate the impact of varying inferior vena cava filter design parameters (number of struts, strut arm length, and tilt angle) on hemodynamics. Results: Recirculation and stagnation areas due to flow velocity and pressure, along with wall shear stress values, were identified as key factors. It is important to find a balance between wall shear stress high enough to aid thrombolysis and low enough to prevent platelet activation. The results of this paper show that the risk of platelet activation and thrombus filtration may be lowest when the wall shear stress of the filter ranges from 0 to 4 [Pa], minimizing stress concentration within the filter. Conclusion: 16 arm struts with a length of 20 mm and a tilt angle of 0 degrees provide the best balance between thrombus capture and minimization of hemodynamic disturbance. This configuration minimizes the size of the stagnation and recirculation zones while maintaining sufficient wall shear stress for thrombus dissolution.
引用
收藏
页数:18
相关论文
共 45 条
[31]   Assessment of a Carbon Fiber Prosthetic Running Blade for Enhanced Reliability [J].
Siddiqui, Md Irfanul Haque ;
Alnaser, Ibrahim Abdullah ;
Alluhydan, Khalid .
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2023, 25 (04)
[32]   Modeling Blood Flow in a Tilted Inferior Vena Cava Filter: Does Tilt Adversely Affect Hemodynamics? [J].
Singer, Michael A. ;
Wang, Stephen L. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (02) :229-235
[33]   Design Optimization of Vena Cava Filters: An Application to Dual Filtration Devices [J].
Singer, Michael A. ;
Wang, Stephen L. ;
Diachin, Darin P. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (10) :1-10
[34]   Tetrahedral vs. polyhedral mesh size evaluation on flow velocity and wall shear stress for cerebral hemodynamic simulation [J].
Spiegel, Martin ;
Redel, Thomas ;
Zhang, Y. Jonathan ;
Struffert, Tobias ;
Hornegger, Joachim ;
Grossman, Robert G. ;
Doerfler, Arnd ;
Karmonik, Christof .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (01) :9-22
[35]   Effects of thrombosed vena cava filters on blood flow: Flow visualization and numerical modeling [J].
Stewart, Sandy F. C. ;
Robinson, Ronald A. ;
Nelson, Robert A. ;
Malinauskas, Richard A. .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (11) :1764-1781
[36]   Carreau Model for Oscillatory Blood Flow in a Tube [J].
Tabakova, S. ;
Nikolova, E. ;
Radev, St .
APPLICATION OF MATHEMATICS IN TECHNICAL AND NATURAL SCIENCES (AMITANS '14), 2014, 1629 :336-343
[37]   An experimental and computational study of the inferior vena cava hemodynamics under respiratory-induced collapse of the infrarenal IVC [J].
Tedaldi, Elisabetta ;
Montanari, Chiara ;
Aycock, Kenneth I. ;
Sturla, Francesco ;
Redaelli, Alberto ;
Manning, Keefe B. .
MEDICAL ENGINEERING & PHYSICS, 2018, 54 :44-55
[38]   Investigation of Wall Shear Stress in Cardiovascular Research and in Clinical Practice-From Bench to Bedside [J].
Urschel, Katharina ;
Tauchi, Miyuki ;
Achenbach, Stephan ;
Dietel, Barbara .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (11)
[39]   Hemodynamic Analysis of VenaTech Convertible Vena Cava Filter Using Computational Fluid Dynamics [J].
Wang, Jingying ;
Huang, Wen ;
Zhou, Yue ;
Han, Fangzhou ;
Ke, Dong ;
Lee, Chunhian .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
[40]   A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth [J].
Wang, Kaihong ;
Armour, Chloee H. ;
Gibbs, Richard G. J. ;
Xu, Xiao Yun .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2024, 23 (01) :61-71