Third-generation posterior-stabilised cemented system for total knee arthroplasty: Survivorship and outcomes after 20-year follow-up

被引:0
作者
Contreras, Jose Luis Patino [1 ]
Perez, Victoria Sebastian [1 ]
Antonio, Checa Garcia [1 ]
Jorge, Montejo Sancho [1 ]
Javier, Martinez Martin [1 ]
机构
[1] Hosp Univ Fdn Alcorcon, Dept Orthoped Surg, Calle Budapest 1, Madrid 28922, Spain
基金
英国科研创新办公室;
关键词
knee arthroplasty; long-term results; posterior-stabilised; revision rate; survivorship; POLYETHYLENE TIBIAL POST; SURVIVAL ANALYSIS; FRACTURE; PROSTHESIS;
D O I
10.1002/jeo2.12063
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTotal knee arthroplasty is a common procedure due to increased life expectancy and ageing populations, necessitating implants with long-term efficacy. After some initial designs, the third-generation modular posterior-stabilised NexGen (R) prosthesis aimed to enhance kinematics and reduce complications. This study evaluates the long-term outcomes, survivorship, revision rates and complications of this implant. With promising results observed up to 15 years in previous studies, this investigation aims to assess the implant's performance over extended follow-up periods, aiding in optimal implant selection for improved patient outcomes.MethodsWe carried out a retrospective study on 263 total knee arthroplasties performed in our centre between 1998 and 2002. Statistical analysis of complications was performed and study of survival using the Kaplan-Meier method and competing risk analysis were calculated. Description of reinterventions and complications were also included.ResultsResults show a 20-year prosthesis survival rate of 90.8% for revision due to any reason, with an estimated survival of 92.3% considering competitive events. Estimated survivorship at 20 years is 98% for aseptic loosening as the end point, and an estimation of 98.80% considering competitive events. Twenty revisions were performed, with 10 cases due to infection and 10 for noninfectious reasons and three of them due to aseptic loosening. Radiographic analysis revealed radiolucent lines, but no clinical evidence of loosening was observed in these cases.ConclusionThis study offers survivorship data from longer follow-up periods, what is difficult to find in the reported literature and showed excellent results of this implant in terms of survivorship and low rates of revision in our cohort.Level of EvidenceLevel IV.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Prospective Clinical Evaluation of Posterior Third-Generation Monolithic Zirconia Crowns Fabricated with Complete Digital Workflow: Two-Year Follow-Up
    Gseibat, Mustafa
    Sevilla, Pablo
    Lopez-Suarez, Carlos
    Rodriguez, Veronica
    Pelaez, Jesus
    Suarez, Maria J.
    MATERIALS, 2022, 15 (02)
  • [32] No Difference in Clinical and Radiologic Outcomes After Total Knee Arthroplasty With a New Ultra-Congruent Mobile Bearing System and Rotating Platform Mobile Bearing Systems After Minimum 5-Year Follow-Up
    Ko, Young-Bong
    Jang, Eui-Chan
    Park, Sang-Min
    Kim, Seong Hwan
    Kwak, Yoon-Ho
    Lee, Han-Jun
    JOURNAL OF ARTHROPLASTY, 2015, 30 (03) : 379 - 383
  • [33] Coronal Alignment Correlates With Outcome After Total Knee Arthroplasty Five-Year Follow-Up of a Randomized Controlled Trial
    Huang, Nathaniel F. R.
    Dowsey, Michelle M.
    Ee, Eric
    Stoney, James D.
    Babazadeh, Sina
    Choong, Peter F.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (09) : 1737 - 1741
  • [34] Relative Clinical Outcomes Comparing Manual and Robotic-Assisted Total Knee Arthroplasty at Minimum 1-Year Follow-up
    Mitchell, Joseph
    Wang, Jesse
    Bukowski, Brett
    Greiner, Justin
    Wolford, Brianna
    Oyer, Mark
    Illgen, Richard L., II
    HSS JOURNAL, 2021, 17 (03) : 267 - 273
  • [35] Survivorship, Outcomes, and Risk Factors for Conversion to Total Hip Arthroplasty After Revision Hip Arthroscopic Surgery in Obese Patients: Results at a Minimum 5-Year Follow-up
    Maldonado, David R. R.
    Lee, Michael S. S.
    Kyin, Cynthia
    Jimenez, Andrew E. E.
    Owens, Jade S. S.
    Perez-Padilla, Paulo A. A.
    Domb, Benjamin G. G.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (04)
  • [36] Does computer-assisted surgery influence survivorship of cementless total knee arthroplasty in patients with primary osteoarthritis? A 10-year follow-up study
    Hervé Ouanezar
    Florent Franck
    Alexandre Jacquel
    Vincent Pibarot
    Julien Wegrzyn
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3448 - 3456
  • [37] Mild Valgus Alignment After Lateral Unicompartmental Knee Arthroplasty Led to Lower Functional Results and Survivorship at Mean 8-Year Follow-Up
    Marullo, Matteo
    Russo, Antonio
    Sprea, Andrea
    Romagnoli, Sergio
    JOURNAL OF ARTHROPLASTY, 2023, 38 (01) : 37 - 42
  • [38] 8-year follow-up after cementless hip arthroplasty with a second generation spongy metal total hip replacement
    Gollwitzer, Hans
    Gerdesmeyer, Ludger
    Horn, Carsten
    Diehl, Peter
    Toepfer, Andreas
    Gradinger, Reiner
    HIP INTERNATIONAL, 2009, 19 (04) : 359 - 366
  • [39] Does computer-assisted surgery influence survivorship of cementless total knee arthroplasty in patients with primary osteoarthritis? A 10-year follow-up study
    Ouanezar, Herve
    Franck, Florent
    Jacquel, Alexandre
    Pibarot, Vincent
    Wegrzyn, Julien
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3448 - 3456
  • [40] Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up
    Gudnason, Asgeir
    Milbrink, Jan
    Hailer, Nils P.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1601 - 1607