Procedural efficiency is enhanced combining the pentaspline pulsed field ablation catheter with three-dimensional electroanatomical mapping system for pulmonary vein isolation

被引:0
|
作者
Zamponi, Alessio Falasca [1 ,2 ]
Olson, Jens [1 ,2 ]
Scheel, Sergej [1 ]
Englund, Anders [1 ]
Scorza, Raffaele [2 ]
Tabrizi, Fariborz [1 ,2 ]
机构
[1] Capio Arytmicenter Stockholm AB, Stockholm, Sweden
[2] Soder Sjukhuset, Karolinska Inst, Dept Clin Sci & Educ, Div Cardiol, Stockholm, Sweden
关键词
Atrial fibrillation; Pulmonary vein isolation; Pulsed field ablation; 3D-EAM; ATRIAL-FIBRILLATION;
D O I
10.1007/s10840-024-01846-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulsed field ablation (PFA) offers a safe, non-thermal alternative for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Currently, the pentaspline PFA-system relies heavily on fluoroscopy for catheter manipulation, which poses challenges due to the complexity of left atrium anatomy. Incorporating three-dimensional electroanatomical mapping (3D-EAM) could improve procedural efficiency reducing dependency on fluoroscopy guidance. This study aims to evaluate the effects of integration of 3D-EAM with PFA during PVI. Methods Between September 2022 and December 2023, we retrospectively enrolled 248 patients with paroxysmal or persistent AF undergoing PVI at our center using the pentaspline PFA catheter. The control group (n = 104) received conventional PFA with fluoroscopic guidance alone, while the intervention group (n = 144) underwent PVI with PFA with 3D-EAM integration. Primary outcomes were procedural time, fluoroscopy time (FT), and dose area product (DAP). Secondary endpoints included acute procedural success and incidence of periprocedural complications. Results In the 3D-EAM-PFA group, procedural time was 63.3 +/- 14.3 min, compared to 65.6 +/- 14.9 min in the control group (p = 0.22). The 3D-EAM group experienced significantly reduced FT (9.7 +/- 4.4 min vs. 16.7 +/- 5.2 min) and DAP (119.2 +/- 121.7 cGycm(2) vs. 338.7 +/- 229.9 cGycm(2)) compared to the control group, respectively (p < 0.001). Acute procedural success was achieved in all cases. No major complications were observed in either group. Conclusion Integration of 3D-EAM with the pentaspline PFA catheter for PVI in AF treatment offers a promising approach, with significantly reduced fluoroscopy exposure without compromising procedural time and efficacy.
引用
收藏
页码:1993 / 2001
页数:9
相关论文
共 50 条
  • [1] How to perform pulmonary vein isolation using a pentaspline pulsed field ablation system for treatment of atrial fibrillation
    Badertscher, Patrick
    Knecht, Sven
    Rosso, Raphael
    Krisai, Philipp
    Spreen, David
    Katic, Josip
    de Lavallaz, Jeanne Du Fay
    Sticherling, Christian
    Kuhne, Michael
    HEART RHYTHM, 2025, 22 (01) : 69 - 79
  • [2] Pulsed field ablation for pulmonary vein isolation: Preclinical safety and effectiveness of a novel hexaspline ablation catheter
    Yu, Fengyuan
    Dong, Xiaonan
    Ding, Lei
    Reddy, Vivek
    Tang, Min
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (11) : 2195 - 2202
  • [3] Pulmonary vein isolation after circumferential pulmonary vein ablation: Comparison between Lasso and three-dimensional electroanatomical assessment of complete electrical disconnection
    Augello, Giuseppe
    Vicedomini, Gabriele
    Saviano, Massimo
    Crisa, Simonetta
    Mazzone, Patrizio
    Ornago, Ombretta
    Zuffada, Francesca
    Santinelli, Vincenzo
    Pappone, Carlo
    HEART RHYTHM, 2009, 6 (12) : 1706 - 1713
  • [4] A pilot clinical assessment of biphasic asymmetric pulsed field ablation catheter for pulmonary vein isolation
    Chen, Bingwei
    Lv, Chang
    Cui, Yingjian
    Lu, Chengzhi
    Cai, Heng
    Xue, Zhixiao
    Xu, Xinyu
    Su, Siying
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [5] Left atrial posterior wall isolation in addition to pulmonary vein isolation using a pentaspline catheter in pulsed-field ablation for atrial fibrillation: A systematic review and meta-analysis
    Pranata, Raymond
    Kamarullah, William
    Karwiky, Giky
    Achmad, Chaerul
    Iqbal, Mohammad
    HEART RHYTHM O2, 2024, 5 (10): : 720 - 727
  • [6] Pulmonary vein isolation and left atrial catheter ablation using a three-dimensional navigation system for the treatment of atrial fibrillation
    Macle, Laurent
    Novak, Paul
    Khairy, Paul
    Thibault, Bernard
    Talajic, Mario
    Dubuc, Marc
    Roy, Denis
    Guerra, Peter G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2009, 25 (06) : E169 - E172
  • [7] Enhanced Efficiency of a Novel Porous Tip Irrigated RF Ablation Catheter for Pulmonary Vein Isolation
    Park, Chan-Il
    Lehrmann, Heiko
    Keyl, Cornelius
    Weber, Reinhold
    Schurr, Patrick
    Schiebeling-Roemer, Jochen
    Allgeier, Juergen
    Herrera, Claudia Siklody
    Kienzle, Rolf-Peter
    Shah, Dipen
    Neumann, Franz-Josef
    Arentz, Thomas
    Jadidi, Amir S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (12) : 1328 - 1335
  • [8] Ostial dimensional changes after pulmonary vein isolation: Pulsed field ablation vs radiofrequency ablation
    Kuroki, Kenji
    Whang, William
    Eggert, Charles
    Lam, Jeff
    Leavitt, Jonas
    Kawamura, Iwanari
    Reddy, Ananya
    Morrow, Blake
    Schneider, Christopher
    Petru, Jan
    Turagam, Mohit K.
    Koruth, Jacob S.
    Miller, Marc A.
    Choudry, Subbarao
    Ellsworth, Betsy
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Reddy, Vivek Y.
    HEART RHYTHM, 2020, 17 (09) : 1528 - 1535
  • [9] Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter
    Yogarajah, Joerg
    Hutter, Julie
    Kahle, Patrick
    Beaujean, Philipp
    Tomic, Marko
    Hain, Andreas
    Sossalla, Samuel
    Kuniss, Malte
    Neumann, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (22)
  • [10] First Experience of Three-dimensional Rotational Angiography Image Integration With Electroanatomical Mapping System to Guide Catheter Ablation of Atrial Fibrillation
    Fujita, Satoshi
    Fujii, Eitaro
    Kagawa, Yoshihiko
    Inoue, Katsuhiro
    Yamada, Tsuyoshi
    Yamada, Norikazu
    Ito, Masaaki
    CIRCULATION, 2016, 134