Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength

被引:11
|
作者
Ogawa, Masato [1 ,2 ]
Matsumoto, Tsuyoshi [3 ]
Harada, Risa [3 ]
Yoshikawa, Ryo [3 ]
Ueda, Yuya [4 ]
Takamiya, Daiki [3 ]
Sakai, Yoshitada [3 ]
机构
[1] Kobe Univ Hosp, Div Rehabil Med, Kobe, Japan
[2] Kobe Univ, Grad Sch Hlth Sci, Dept Publ Hlth, Kobe, Japan
[3] Kobe Univ, Grad Sch Med, Div Rehabil Med, Kobe, Japan
[4] Kobe Univ, Grad Sch Hlth Sci, Dept Rehabil Med, Kobe, Japan
关键词
muscle thickness; reliability; ultrasonography; validity; BODY-COMPOSITION; ULTRASOUND;
D O I
10.2490/prm.20230008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment. Methods: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference. Results: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant. Conclusions: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Reliability and validity of pelvic floor muscle strength assessment using the MizCure perineometer
    Abe-Takahashi, Yui
    Kitta, Takeya
    Ouchi, Mifuka
    Okayauchi, Minori
    Chiba, Hiroki
    Higuchi, Madoka
    Togo, Mio
    Shinohara, Nobuo
    BMC WOMENS HEALTH, 2020, 20 (01)
  • [42] The Validity and Reliability of a Sphygmomanometer in Assessing Isometric Muscle Strength of Shoulder Flexors and Abductors
    Ilyas, Arzish
    Ahmad, Ashfaq
    Gillani, Syed Amir
    Bukhari, Bazal
    Gillani, Humna
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2019, 25 (04):
  • [43] Validity of muscle thickness-based prediction equation for quadriceps femoris volume in middle-aged and older men and women
    Nakatani, Miyuki
    Takai, Yohei
    Akagi, Ryota
    Wakahara, Taku
    Sugisaki, Norihide
    Ohta, Megumi
    Kawakami, Yasuo
    Fukunaga, Tetsuo
    Kanehisa, Hiroaki
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (11-12) : 2125 - 2133
  • [44] Ultrasonographic Quantification of Intrinsic Hand Muscle Cross-Sectional Area; Reliability and Validity for Predicting Muscle Strength
    Mohseny, Behnam
    Nijhuis, Tim H.
    Hundepool, Caroline A.
    Janssen, Wim G.
    Selles, Ruud W.
    Coert, J. Henk
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (05): : 845 - 853
  • [45] Role of Ultrasonography in Estimating Muscle Mass in Sarcopenic Obesity
    Deniz, Olgun
    Cruz-Jentoft, Alfonso
    Aycicek, Gozde Sengul
    Unsal, Pelin
    Esme, Mert
    Ucar, Yelda
    Burkuk, Suna
    Sendur, Ayse
    Yavuz, Burcu Balam
    Cankurtaran, Mustafa
    Halil, Meltem
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2020, 44 (08) : 1398 - 1406
  • [46] Muscle thickness and echo intensity measurements of the rectus femoris muscle of healthy subjects: Intra and interrater reliability of transducer tilt during ultrasound
    Ishida, Hiroshi
    Suehiro, Tadanobu
    Suzuki, Keita
    Watanabe, Susumu
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2018, 22 (03) : 657 - 660
  • [47] Gastrocnemius thickness by ultrasonography indicates the low skeletal muscle mass in Japanese elderly people
    Yuguchi, Satoshi
    Asahi, Ryoma
    Kamo, Tomohiko
    Azami, Masato
    Ogihara, Hirofumi
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2020, 90
  • [48] Ultrasonography to measure quadriceps muscle in critically ill patients: A literature review of reported methodologies
    Weinel, Luke M.
    Summers, Matthew J.
    Chapple, Lee-Anne
    ANAESTHESIA AND INTENSIVE CARE, 2019, 47 (05) : 423 - 434
  • [49] Changes in quadriceps muscle thickness in acute non-ambulatory stroke survivors
    Nozoe, Masafumi
    Kanai, Masashi
    Kubo, Hiroki
    Kitamura, Yuka
    Shimada, Shinichi
    Mase, Kyoshi
    TOPICS IN STROKE REHABILITATION, 2016, 23 (01) : 26 - 32
  • [50] Validity of ultrasound muscle thickness measurements for predicting leg skeletal muscle mass in healthy Japanese middle-aged and older individuals
    Takai, Yohei
    Ohta, Megumi
    Akagi, Ryota
    Kato, Emika
    Wakahara, Taku
    Kawakami, Yasuo
    Fukunaga, Tetsuo
    Kanehisa, Hiroaki
    JOURNAL OF PHYSIOLOGICAL ANTHROPOLOGY, 2013, 32