Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength

被引:11
|
作者
Ogawa, Masato [1 ,2 ]
Matsumoto, Tsuyoshi [3 ]
Harada, Risa [3 ]
Yoshikawa, Ryo [3 ]
Ueda, Yuya [4 ]
Takamiya, Daiki [3 ]
Sakai, Yoshitada [3 ]
机构
[1] Kobe Univ Hosp, Div Rehabil Med, Kobe, Japan
[2] Kobe Univ, Grad Sch Hlth Sci, Dept Publ Hlth, Kobe, Japan
[3] Kobe Univ, Grad Sch Med, Div Rehabil Med, Kobe, Japan
[4] Kobe Univ, Grad Sch Hlth Sci, Dept Rehabil Med, Kobe, Japan
关键词
muscle thickness; reliability; ultrasonography; validity; BODY-COMPOSITION; ULTRASOUND;
D O I
10.2490/prm.20230008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment. Methods: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference. Results: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant. Conclusions: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The effects of early neurodevelopmental Bobath approach and mobilization on quadriceps muscle thickness in stroke patients
    Guclu Gunduz, Arzu
    Yazici, Gokhan
    Ozkul, Cagla
    Kucuk, Hamit
    Batur Caglayan, Hale Zeynep
    Nazliel, Bijen
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (01) : 318 - 326
  • [32] Seasonal phenotypic flexibility of flight muscle size in small birds: a comparison of ultrasonography and tissue mass measurements
    Swanson, David L.
    Merkord, Chris
    JOURNAL OF ORNITHOLOGY, 2013, 154 (01) : 119 - 127
  • [33] DOES REST TIME BEFORE ULTRASONOGRAPHY IMAGING AFFECT QUADRICEPS FEMORIS MUSCLE THICKNESS, CROSS-SECTIONAL AREA AND ECHO INTENSITY MEASUREMENTS?
    Lopez, Pedro
    Pinto, Matheus Daros
    Pinto, Ronei Silveira
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02): : 612 - 616
  • [34] Reliability of the lateral abdominal muscle thickness measurements in idiopathic scoliosis patients
    Linek, Pawel
    Klepek, Anna
    Wolny, Tomasz
    Mikolajowski, Grzegorz
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2018, 38 : 151 - 154
  • [35] Ultrasound quadriceps muscle thickness is variably associated with frailty in haemodialysis recipients
    Anderson, Benjamin M.
    Wilson, Daisy V.
    Qasim, Muhammad
    Correa, Gonzalo
    Evison, Felicity
    Gallier, Suzy
    Ferro, Charles J.
    Jackson, Thomas A.
    Sharif, Adnan
    BMC NEPHROLOGY, 2023, 24 (01)
  • [36] Reliability of point-of-care ultrasound for measuring quadriceps femoris muscle thickness
    Pinto-Ramos, Joao
    Costa-Santos, Cristina
    Costa, Frederico
    Tavares, Helena
    Cabral, Joao
    Moreira, Tiago
    Brito, Rui
    Barroso, Joana
    Sousa-Pinto, Bernardo
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (05) : 767 - 773
  • [37] Intra- and inter-rater reliability of muscle and fat thickness measurements obtained using portable ultrasonography in older adults
    de Oliveira, Gabriela Benatti
    Fernandes, Lara Vilar
    Chen, Xiayu Summer
    Andrade, Flavia Cristina Drumond
    Costa, Luciana Scarlazzari
    Vasques, Ana Carolina Junqueira
    Corona, Ligiana Pires
    CLINICAL NUTRITION ESPEN, 2024, 60 : 65 - 72
  • [38] Reliability and validity of pelvic floor muscle strength assessment using the MizCure perineometer
    Yui Abe-Takahashi
    Takeya Kitta
    Mifuka Ouchi
    Minori Okayauchi
    Hiroki Chiba
    Madoka Higuchi
    Mio Togo
    Nobuo Shinohara
    BMC Women's Health, 20
  • [39] Association between ultrasound measurements of muscle thickness, pennation angle, echogenicity and skeletal muscle strength in the elderly
    Strasser, Eva Maria
    Draskovits, Thomas
    Praschak, Markus
    Quittan, Michael
    Graf, Alexandra
    AGE, 2013, 35 (06) : 2377 - 2388
  • [40] The concurrent validity of a portable ultrasound probe for muscle thickness measurements
    Homer, Kai A.
    Cross, Matt R.
    Jukic, Ivan
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2025, 45 (01)