Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength

被引:11
|
作者
Ogawa, Masato [1 ,2 ]
Matsumoto, Tsuyoshi [3 ]
Harada, Risa [3 ]
Yoshikawa, Ryo [3 ]
Ueda, Yuya [4 ]
Takamiya, Daiki [3 ]
Sakai, Yoshitada [3 ]
机构
[1] Kobe Univ Hosp, Div Rehabil Med, Kobe, Japan
[2] Kobe Univ, Grad Sch Hlth Sci, Dept Publ Hlth, Kobe, Japan
[3] Kobe Univ, Grad Sch Med, Div Rehabil Med, Kobe, Japan
[4] Kobe Univ, Grad Sch Hlth Sci, Dept Rehabil Med, Kobe, Japan
关键词
muscle thickness; reliability; ultrasonography; validity; BODY-COMPOSITION; ULTRASOUND;
D O I
10.2490/prm.20230008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment. Methods: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference. Results: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant. Conclusions: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of the Quadriceps Muscle Thickness and Function between Patients with Patellofemoral Pain Syndrome and Healthy Subjects using Ultrasonography: An Observational Study
    Ezzati, Kamran
    Soleymanha, Mehran
    Asadi, Kamran
    Ettehad, Hossein
    Khansha, Rahman
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (12): : 859 - 865
  • [22] Noninvasive evaluation of muscle mass by ultrasonography of quadriceps femoris muscle in End-Stage Renal Disease patients on hemodialysis
    Sabatino, Alice
    Regolisti, Giuseppe
    Delsante, Marco
    Di Motta, Tommaso
    Cantarelli, Chiara
    Pioli, Sarah
    Grassi, Giulia
    Batini, Valentina
    Gregorini, Mariacristina
    Fiaccadori, Enrico
    CLINICAL NUTRITION, 2019, 38 (03) : 1232 - 1239
  • [23] Relationship between ultrasonographic hand muscle thickness measurements and muscle strength following median or ulnar nerve reconstruction
    Misirlioglu, T. O.
    Palamar, Deniz
    Taskiran, Ozden Ozyemisci
    Terlemez, Rana
    Akgun, Kenan
    MUSCLE & NERVE, 2021, 63 (03) : 351 - 356
  • [24] Regional and total muscle mass, muscle strength and physical performance: The potential use of ultrasound imaging for sarcopenia
    Ata, Ayse Merve
    Kara, Murat
    Kaymak, Bayram
    Gurcay, Eda
    Cakir, Banu
    Unlu, Hande
    Akinci, Aysen
    Ozcakar, Levent
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2019, 83 : 55 - 60
  • [25] An Analysis of Reliability and Accuracy of Muscle Thickness Ultrasonography in Critically Ill Children and Adults
    Fivez, Tom
    Hendrickx, Alexandra
    Van Herpe, Tom
    Vlasselaers, Dirk
    Desmet, Lars
    Van den Berghe, Greet
    Mesotten, Dieter
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2016, 40 (07) : 944 - 949
  • [26] Quadriceps muscle architecture ultrasonography of individuals with type 2 diabetes: Reliability and applicability
    de Souza Silva, Camilla Rodrigues
    Costa, Andre dos Santos
    Rocha, Taciano
    Martins de Lima, Diogo Arruda
    do Nascimento, Tamires
    Arruda de Moraes, Silvia Regina
    PLOS ONE, 2018, 13 (10):
  • [27] Estimation of Validity of A-Mode Ultrasound for Measurements of Muscle Thickness and Muscle Quality
    Lee, Ji-Won
    Hong, Seung-Ug
    Lee, Ju-Hee
    Park, Sung-Yun
    BIOENGINEERING-BASEL, 2024, 11 (02):
  • [28] Reliability of knee muscle strength and fatigue measurements
    Surakka, J
    Virtanen, A
    Aunola, S
    Mäentaka, K
    Pekkarinen, H
    BIOLOGY OF SPORT, 2005, 22 (04) : 301 - 313
  • [29] Validity and reliability of elastic resistance bands for measuring shoulder muscle strength
    Andersen, L. L.
    Vinstrup, J.
    Jakobsen, M. D.
    Sundstrup, E.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2017, 27 (08) : 887 - 894
  • [30] Reliability of ultrasound in the assessment of muscle thickness in critically ill children
    de Oliveira, Jessica Knisspell
    Schaan, Camila Wohlgemuth
    Silva, Cristiano Kohler
    Piva, Taila Cristina
    Sousa, Ian Teixeira e
    Bruno, Francisco
    Lukrafka, Janice Luisa
    ANALES DE PEDIATRIA, 2023, 98 (06): : 411 - 417