The utility of virtual monochromatic dual-energy computed tomography (DECT) in meniscal imaging: a technical evaluation

被引:0
|
作者
Adams, Scott [1 ]
van Heerden, Jacques [1 ]
Reis, Jodie [1 ]
Mondal, Prosanta [1 ]
Shepel, Michael [1 ]
Obaid, Haron [1 ]
机构
[1] Univ Saskatchewan, Saskatoon, SK, Canada
关键词
dual-energy CT; meniscus; contrast resolution; ANTERIOR CRUCIATE LIGAMENT; CT; PERFORMANCE; ARTHROSCOPY; DIAGNOSIS; TEARS;
D O I
10.5114/pjr/187934
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the feasibility of meniscal imaging using virtual monochromatic images obtained through dualenergy computed tomography (DECT) technique, and to determine which keV levels optimise contrast resolution. Material and methods: All DECT exams were performed on a Discovery CT750 HD system from GE Healthcare. Virtual monochromatic images were reconstructed at 40 keV, 73 keV, 106 keV, and 139 keV. Contrast resolution of the medial and lateral menisci using a 5-point Likert scale at each keV level was determined through a consensus agreement by 2 fellowship-trained musculoskeletal radiologists. Friedman's and Wilcoxon signed rank tests were used to compare visualisation scores across different keV levels. Results: Seventeen knee exams from 10 patients met criteria for inclusion in the study. All patients included in the study cohort were male. The median age of patients was 46 years (interquartile range, 35-53 years). Virtual monochromatic images at 40 keV demonstrated highest contrast resolution of the menisci, with a statistically significant difference between contrast resolution scores at 40 keV and 76 keV, Friedman test: p < 0.0001. Conclusions: Meniscal imaging is feasible using DECT virtual monochromatic images at low keV levels. Improved contrast resolution at these specified KeV values could pave the way for further research in this field to determine its role in the future as an alternative option for assessment of the menisci in patients with contraindications to MRI or in the setting of a periarticular ferromagnetic foreign body obscuring the field of view.
引用
收藏
页码:e324 / e327
页数:4
相关论文
共 50 条
  • [1] Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing
    Taguchi, Narumi
    Oda, Seitaro
    Imuta, Masanori
    Yamamura, Sadahiro
    Yokota, Yasuhiro
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 7 - 12
  • [2] Assessment of dual-energy computed tomography derived virtual monochromatic imaging for target volume delineation of brain metastases
    Kraft, Johannes
    Lutyj, Paul
    Grabenbauer, Felix
    Stroehle, Serge-Peer
    Tamihardja, Joerg
    Razinskas, Gary
    Weick, Stefan
    Richter, Anne
    Huflage, Henner
    Wittig, Andrea
    Flentje, Michael
    Lisowski, Dominik
    RADIOTHERAPY AND ONCOLOGY, 2023, 187
  • [3] Dual-Energy Computed Tomography in Genitourinary Imaging
    Mileto, Achille
    Marin, Daniele
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (02) : 373 - +
  • [4] Dual-Energy Computed Tomography Virtual Monoenergetic Imaging of Lung Cancer: Assessment of Optimal Energy Levels
    Kaup, Moritz
    Scholtz, Jan-Erik
    Engler, Alexander
    Albrecht, Moritz H.
    Bauer, Ralf W.
    Kerl, J. Matthias
    Beeres, Martin
    Lehnert, Thomas
    Vogl, Thomas J.
    Wichmann, Julian L.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 80 - 85
  • [5] Virtual Monochromatic Images from Dual-Energy Computed Tomography Do Not Improve the Detection of Synovitis in Hand Arthritis
    Ulas, Sevtap Tugce
    Ziegeler, Katharina
    Richter, Sophia-Theresa
    Ohrndorf, Sarah
    Proft, Fabian
    Poddubnyy, Denis
    Diekhoff, Torsten
    DIAGNOSTICS, 2022, 12 (08)
  • [6] Imaging of nanoparticles with dual-energy computed tomography
    Ducote, J. L.
    Alivov, Y.
    Molloi, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07) : 2031 - 2044
  • [7] Evaluation of virtual monochromatic imaging with dual-energy computed tomography of small liver metastases from malignant abdominal tumours: Quantitative and qualitative analyses
    Okada, Hiroaki
    Matsunaga, Nozomu
    Yamamoto, Takahiro
    Yamauchi, Masato
    Suzuki, Kojiro
    ACTA RADIOLOGICA OPEN, 2023, 12 (12)
  • [8] Comparison of gastric vascular anatomy by monochromatic and polychromatic dual-energy spectral computed tomography imaging
    Wan, Yamin
    Li, Zhizhen
    Ji, Nina
    Gao, Jianbo
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (01) : 26 - 34
  • [9] Dual-energy Computed Tomography (DECT) Scan for Determination of Renal Stone Composition: A Phantom Study
    Sheikhi, Mahboobeh
    Sina, Sedigheh
    Karimipourfard, Mehrnoosh
    IRANIAN JOURNAL OF RADIOLOGY, 2023, 20 (03)
  • [10] Periprosthetic Artifact Reduction Using Virtual Monochromatic Imaging Derived From Gemstone Dual-Energy Computed Tomography and Dedicated Software
    Reynoso, Exequiel
    Capunay, Carlos
    Rasumoff, Alejandro
    Vallejos, Javier
    Carpio, Jimena
    Lago, Karen
    Carrascosa, Patricia