Structural Validity of the Mini-Balance Evaluation Systems Test in Individuals With Spinocerebellar Ataxia: A Rasch Analysis Study

被引:3
|
作者
Miyata, Kazuhiro [1 ]
Kondo, Yuki [2 ]
Bando, Kyota [2 ]
Hara, Takatoshi [2 ]
Takahashi, Yuji [3 ]
机构
[1] Ibar aki Prefectural Univ Hlth Sci, Dept Phys Therapy, 4669-2 Ami Machi, Tsukuba, Ibaraki 3000394, Japan
[2] Natl Ctr Hosp, Natl Ctr Neurol & Psychiat, Dept Phys Rehabil, Kodaira, Japan
[3] Natl Ctr Hosp, Natl Ctr Neurol & Psychiat, Dept Neurol, Kodaira, Japan
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2024年 / 105卷 / 04期
基金
日本学术振兴会;
关键词
Cerebellar ataxia; Postural balance; Psychometrics; Rehabilitation; CEREBELLAR-ATAXIA; BESTEST; VALIDATION; SCALE; FALLS;
D O I
10.1016/j.apmr.2023.12.015
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To examine the structural validity of the Mini-Balance Evaluation Systems Test (Mini-BESTest) in individuals with spinocerebellar ataxia (SCA). Design: Methodological research on data gathered in a cross-sectional study. A Rasch analysis was conducted (partial credit model). Setting: Inpatients in a hospital rehabilitation setting. Participants: A pooled sample of patients with SCA (N=65 [total 110 data]; 23 women, 42 men; mean +/- SD age 63.1 +/- 9.9y). Interventions: Not applicable. Main Outcome Measures: We evaluated the Mini-BESTest's category structure, unidimensionality, and measurement accuracy (0: unable to perform or requiring help to 2: normal performance). Results: The Mini-BESTest rating scale fulfilled the category functioning criteria. The analysis of the standardized Rasch residuals showed the scale's unidimensionality, but there were 7 item pairs indicating local dependence. All of the items fit the underlying scale construct (dynamic balance), with the exception of item #1, "Sit to stand," which was an underfit. The Mini-BESTest demonstrated adequate reliability (person separation reliability=.87) and separated the patients into 5 strata. The item-difficulty measures ranged from -4.49 to 2.02 logits, and the person ability -item difficulty matching was very good (the mean of person ability=-.07 logits and the mean of item difficulty=.00). No floor or ceiling effects were detected. The keyform identified items with small (#11, "Walk with head turns, horizontal") and large (#3, "Stand on 1 leg") item thresholds. Conclusions: The Mini-BESTest has a unidimensional balance assessment scale with good category structure and reliability even for individuals with SCA. However, it also has some inherent shortcomings such as fit statistics, local item dependencies, and item thresholds. The results obtained when the Mini-BESTest is administered to patients with cerebellar ataxia should, thus, be interpreted cautiously. Archives of Physical Medicine and Rehabilitation 2024;105:742 -9 (c) 2024 by the American Congress of Rehabilitation Medicine.
引用
收藏
页码:742 / 749
页数:8
相关论文
共 38 条
  • [1] Reliability, Validity, and Responsiveness of the Mini-Balance Evaluation Systems Test in Ambulatory Individuals with Multiple Sclerosis
    Potter, Kirsten
    Bowling, Rachel
    Kavanagh, Lindsey
    Stone, Ashley
    Witt, Brittany
    Wooldridge, Ashley
    PHYSIOTHERAPY CANADA, 2019, 71 (04) : 327 - 334
  • [2] Structural Validity of the Mini-Balance Evaluation Systems Test (Mini-BESTest) in People With Mild to Moderate Parkinson Disease
    Wallen, Martin Benka
    Sorjonen, Kimmo
    Lofgren, Niklas
    Franzen, Erika
    PHYSICAL THERAPY, 2016, 96 (11): : 1799 - 1806
  • [3] Reliability and Validity of the Persian Version of the Mini-Balance Evaluation Systems Test in Patients with Stroke
    Naghdi, Soofia
    Ansari, Noureddin Nakhostin
    Forogh, Bijan
    Khalifeloo, Maedeh
    Honarpisheh, Roshanak
    Nakhostin-Ansari, Amin
    NEUROLOGY AND THERAPY, 2020, 9 (02) : 567 - 574
  • [4] Psychometric properties of the Arabic version of the Mini-Balance Evaluation Systems Test in patients with neurological balance disorders
    Alyousef, N. I.
    Shaheen, A. A. M.
    Elsayed, W.
    Alsubiheen, A. M.
    Farrag, A.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (10) : 4337 - 4347
  • [5] Reliability, Validity, and Ability to Identify Fall Status of the Balance Evaluation Systems Test, Mini-Balance Evaluation Systems Test, and Brief-Balance Evaluation Systems Test in Older People Living in the Community
    Marques, Alda
    Almeida, Sara
    Carvalho, Joana
    Cruz, Joana
    Oliveira, Ana
    Jacome, Cristina
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2016, 97 (12): : 2166 - 2173
  • [6] Validity, reliability, and responsiveness of Persian version of mini-balance evaluation system test among ambulatory people with multiple sclerosis
    Molhemi, Farshad
    Monjezi, Saeideh
    Mehravar, Mohammad
    Shaterzadeh-Yazdi, Mohammad-Jafar
    Majdinasab, Nastaran
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024, 40 (03) : 565 - 575
  • [7] Psychometric Properties of the Mini-Balance Evaluation Systems Test (Mini-BESTest) in Community-Dwelling Individuals With Chronic Stroke
    Tsang, Charlotte S. L.
    Liao, Lin-Rong
    Chung, Raymond C. K.
    Pang, Marco Y. C.
    PHYSICAL THERAPY, 2013, 93 (08): : 1102 - 1115
  • [8] The minimal clinically important difference of the mini-balance evaluation systems test in patients with early subacute stroke
    Takeda, Ren
    Miyata, Kazuhiro
    Igarashi, Tatsuya
    TOPICS IN STROKE REHABILITATION, 2023, 30 (07) : 672 - 680
  • [9] Reliability and Validity of Mini-Balance Evaluation System Test in Type 2 Diabetic Patients with Peripheral Neuropathy
    Phyu, Sitt Nyein
    Peungsuwan, Punnee
    Puntumetakul, Rungthip
    Chatchawan, Uraiwan
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (11)
  • [10] Pooled Minimal Clinically Important Differences of the Mini-Balance Evaluation Systems Test in Patients With Early Subacute Stroke: A Multicenter Prospective Observational Study
    Tamura, Shuntaro
    Miyata, Kazuhiro
    Hasegawa, Satoshi
    Kobayashi, Sota
    Shioura, Kosuke
    Usuda, Shigeru
    PHYSICAL THERAPY, 2024, 104 (04):