Effectiveness of a nurse-led peripherally inserted central catheter service: A retrospective cohort study

被引:0
|
作者
Alsaleh, Kawthar [1 ]
Alosaimi, Dalyal [1 ]
Almousawi, Adnan [2 ]
Alshaikh, Mohammed [3 ]
Omar, Hisham [3 ]
机构
[1] King Saud Univ, Coll Nursing, Med Surg Nursing Dept, King Khalid Rd, Riyadh 11362, Saudi Arabia
[2] King Fahad Hufuf Hosp, AlAhsa Hlth Cluster, Minist Hlth, Intens Care Unit, AlAhsa, Saudi Arabia
[3] King Fahad Med City, Intervent Radiol Dept, Riyadh, Saudi Arabia
关键词
Nurse-led; peripherally inserted central catheter; PICC; CENTRAL VENOUS CATHETERS; VASCULAR ACCESS; COMPLICATIONS; PLACEMENT; TIP; INFECTION; POSITION; RISK;
D O I
10.1177/11297298241263886
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: A multitude of challenges arises from the growing utilisation of peripherally inserted central catheters (PICCs), including the ability to provide timely, effective and safe insertion, which must be ensured and prioritised in patient care. A nurse-led model of care has become more prevalent as PICCs become extensively needed due to their applications. However, despite their widespread use, such intervention is yet in its inception in Saudi Arabia, and thereby, evaluating the outcomes of this service is of utmost importance to support patient safety initiatives and quality of care.Purpose: This research aims to assess the effectiveness of a nurse-led PICC placement service.Methods: A quantitative retrospective cohort design was used. The sample of this study was 333 random subsets of records on PICC insertion for adult patients between 1st April 2019 and 31st March 2023 in a tertiary medical facility in Riyadh, Saudi Arabia.Results: A nurse-led PICC service demonstrated an overall successful placement of 330 cases (99.1%), out of which 323 PICCs (97%) were successfully inserted under intra-cavitary electrocardiogram (IC-ECG) guidance, while 7 PICCs (2.1%) were successfully inserted with fluoroscopy. The overall complication rate was 2.35 occurrences per 1000 CL days, whereas the complication rate within the first 10 days after PICC insertion was 0.42 per 1000 CL days.Conclusion: A nurse-led model for PICC insertion has remarkably high success rates and low rates of complication, highlighting the pivotal role of a specialised PICC team. This service boasted a commendable track record of achieving a high rate of success in its implementation, implying that a nurse-led PICC service operates effectively to improve the patient experience by delivering timely and high-quality healthcare service.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Peripherally Inserted Central Venous Catheter Safety in Burn Care: A Single-Center Retrospective Cohort Review
    Austin, Ryan E.
    Shahrokhi, Shahriar
    Bolourani, Siavash
    Jeschke, Marc G.
    JOURNAL OF BURN CARE & RESEARCH, 2015, 36 (01) : 111 - 117
  • [32] Effectiveness of Synthetic Polymer-coated Peripherally Inserted Central Catheter in Patients With Advanced Cancer
    Takezawa, Yuta
    Izumi, Kouji
    Kamijima, Taiki
    Machioka, Kazuaki
    Shima, Takashi
    Iwamoto, Hiroaki
    Nohara, Takahiro
    Shigehara, Kazuyoshi
    Kadono, Yoshifumi
    Seto, Chikashi
    Mizokami, Atsushi
    IN VIVO, 2019, 33 (03): : 877 - 880
  • [33] Inadvertent Arterial Peripherally Inserted Central Catheter Insertion With Corresponding Electrocardiographic Tracings: A Case Report
    DiLoreto, Emily
    Bahl, Amit
    JOURNAL OF INFUSION NURSING, 2022, 45 (01) : 37 - 40
  • [34] The establishment and evaluation of rabbit model for peripherally inserted central catheter
    Zhang, Jing
    Yin, Weiwei
    Jiang, Yumin
    Juan, Shen
    ACTA CIRURGICA BRASILEIRA, 2014, 29 (08) : 493 - 498
  • [35] Accuracy of Intravenous Electrocardiography Confirmation of Peripherally Inserted Central Catheter for Parenteral Nutrition
    Mundi, Manpreet S.
    Varayil, Jithinraj Edakkanambeth
    McMahon, Megan T.
    Okano, Akiko
    Vallumsetla, Nishanth
    Bonnes, Sara L.
    Andrews, James C.
    Hurt, Ryan T.
    NUTRITION IN CLINICAL PRACTICE, 2016, 31 (02) : 207 - 210
  • [36] Peripherally inserted central catheter in pediatric oncology: a scoping review
    Bortoli, Paula Saud Be
    Andrade Biaggi Leite, Ana Carolina
    Alvarenga, Willyane de Andrade
    Alvarenga, Carolina Spinelli
    Bessa, Caroline Rabaza
    Nascimento, Lucila Castanheira
    ACTA PAULISTA DE ENFERMAGEM, 2019, 32 (02) : 220 - 228
  • [37] A model for a nurse-led programme of bedside placement of peripherally inserted central catheters in neonates and infants with congenital cardiac disease
    King, Deborah S.
    da Cruz, Eduardo
    Kaufman, Jon
    CARDIOLOGY IN THE YOUNG, 2010, 20 (03) : 302 - 307
  • [38] Comparison of complications between pediatric peripherally inserted central catheter placement techniques
    Dasgupta, Niloy
    Patel, Manish N.
    Racadio, John M.
    Johnson, Neil D.
    Lungren, Matthew P.
    PEDIATRIC RADIOLOGY, 2016, 46 (10) : 1439 - 1443
  • [39] Modified Insertion of a Peripherally Inserted Central Catheter: Taking the Chest Radiograph Earlier
    Tian, Geng
    Chen, Bin
    Qi, Li
    Zhu, Yan
    CRITICAL CARE NURSE, 2011, 31 (02) : 64 - 69
  • [40] Venous thrombosis and stenosis after peripherally inserted central catheter placement in children
    Shin, H. Stella
    Towbin, Alexander J.
    Zhang, Bin
    Johnson, Neil D.
    Goldstein, Stuart L.
    PEDIATRIC RADIOLOGY, 2017, 47 (12) : 1670 - 1675