AAPM WGTG51 Report 385: Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy electron beams

被引:0
|
作者
Muir, Bryan [1 ]
Davis, Stephen [2 ]
Dhanesar, Sandeep [3 ]
Hillman, Yair [4 ]
Iakovenko, Viktor [5 ]
Kim, Grace Gwe-Ya [6 ]
Alves, Victor Gabriel Leandro [7 ]
Lei, Yu [8 ]
Lowenstein, Jessica [9 ]
Renaud, James [1 ]
Sarfehnia, Arman [10 ,11 ]
Siebers, Jeffrey [7 ]
Tantot, Laurent [12 ]
机构
[1] Natl Res Council Canada, Metrol Res Ctr, Ottawa, ON, Canada
[2] Miami Canc Inst, Dept Radiat Oncol, Miami, FL USA
[3] Houston Methodist Hosp, Dept Radiat Oncol, Houston, TX USA
[4] Hebrew Univ Jerusalem, Sharett Inst Oncol, Hadassah Med Ctr, Dept Radiat Oncol, Jerusalem, Israel
[5] UT Southwestern Med Ctr, Dallas, TX USA
[6] UC San Diego Sch Med, Dept Radiat Med & Appl Sci, San Diego, CA USA
[7] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA USA
[8] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE USA
[9] UT MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
[10] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[11] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Med Phys, Toronto, ON, Canada
[12] Hop Maison Neuve Rosemont, CIUSSS Est Ile de Montreal, Dept Radiooncol, Montreal, PQ, Canada
关键词
absorbed-dose calibration coefficient; beam quality conversion factor; dosimetry protocol; electron beam; ionization chamber; uncertainty analysis; kQ; PARALLEL IONIZATION CHAMBERS; QUALITY CONVERSION FACTORS; MONTE-CARLO CALCULATIONS; EFFECTIVE POINT; ION CHAMBERS; CALIBRATION COEFFICIENTS; PERTURBATION CORRECTION; PLATE CHAMBERS; PHOTON; POLARITY;
D O I
10.1002/mp.17277
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An Addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water is presented for electron beams with energies between 4 MeV and 22 MeV (1.70cm <= R-50 <= 8.70cm). This updated formalism allows simplified calibration procedures, including the use of calibrated cylindrical ionization chambers in all electron beams without the use of a gradient correction. New k(Q) data are provided for electron beams based on Monte Carlo simulations. Implementation guidance is provided. Components of the uncertainty budget in determining absorbed dose to water at the reference depth are discussed. Specifications for a reference-class chamber in electron beams include chamber stability, settling, ion recombination behavior, and polarity dependence. Progress in electron beam reference dosimetry is reviewed. Although this report introduces some major changes (e.g., gradient corrections are implicitly included in the electron beam quality conversion factors), they serve to simplify the calibration procedure. Results for absorbed dose per linac monitor unit are expected to be up to approximately 2 % higher using this Addendum compared to using the original TG-51 protocol.
引用
收藏
页码:5840 / 5857
页数:18
相关论文
共 5 条
  • [1] Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams
    McEwen, Malcolm
    DeWerd, Larry
    Ibbott, Geoffrey
    Followill, David
    Rogers, David W. O.
    Seltzer, Stephen
    Seuntjens, Jan
    MEDICAL PHYSICS, 2014, 41 (04)
  • [2] AAPM WGTG51 Report 374: Guidance for TG-51 reference dosimetry
    Muir, Bryan
    Culberson, Wesley
    Davis, Stephen
    Kim, Grace Gwe-Ya
    Lee, Sung-Woo
    Lowenstein, Jessica
    Renaud, James
    Sarfehnia, Arman
    Siebers, Jeffrey
    Tantot, Laurent
    Tolani, Naresh
    MEDICAL PHYSICS, 2022, 49 (11) : 6739 - 6764
  • [3] Comparison of the recommendations of the AAPM TG-51 and TG-51 addendum reference dosimetry protocols
    McCaw, Travis J.
    Hwang, Min-Sig
    Jang, Si Young
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 140 - 143
  • [4] Effect of ICRU report 90 recommendations on Monte Carlo calculated kQ for ionization chambers listed in the Addendum to AAPM's TG-51 protocol
    Kawachi, Toru
    Saitoh, Hidetoshi
    Katayose, Tetsurou
    Tohyama, Naoki
    Miyasaka, Ryohei
    Cho, Sang Yong
    Iwase, Tsutomu
    Hara, Ryusuke
    MEDICAL PHYSICS, 2019, 46 (11) : 5185 - 5194
  • [5] Electron dosimetry based on the absorbed dose to water concept:: A comparison of the AAPM TG-51 and DIN 6800-2 protocols
    Dohm, OS
    Christ, G
    Nüsslin, F
    Schüle, E
    Bruggmoser, G
    MEDICAL PHYSICS, 2001, 28 (11) : 2258 - 2264