Asymmetric pulses delivered by a cochlear implant allow a reduction in evoked firing rate and in spatial activation in the guinea pig auditory cortex

被引:0
作者
Adenis, V. [1 ,2 ,3 ,6 ]
Partouche, E. [1 ,2 ,3 ]
Stahl, P. [4 ]
Gnansia, D. [4 ]
Huetz, C. [1 ,2 ,3 ]
Edeline, J. -m [1 ,2 ,3 ,5 ]
机构
[1] Paris Saclay Inst Neurosci Neuro PSI, Saclay, France
[2] CNRS, UMR 9197, F-91405 Orsay, France
[3] Univ Paris Saclay, F-91405 Orsay, France
[4] Oticon Med, Vallauris, France
[5] Ctr CEA Saclay, Inst Neurosci Paris Saclay, UMR 9197, Neuropsi, Batiment151,151 Route Rotonde, F-91400 Saclay, France
[6] Mass Eye & Ear Inst, Eaton Peabody Labs, 234 Charles St, Boston, MA 02114 USA
关键词
Cochlear implant; Auditory cortex; Electrophysiology; Cortical activation; Pulse shape; Guinea pig; ELECTRODE-NEURON INTERFACE; RECEPTIVE-FIELD PLASTICITY; FACIAL-NERVE STIMULATION; ELECTRICAL-STIMULATION; STIMULUS POLARITY; SPEECH-PERCEPTION; EXCITATION PATTERNS; ACTION-POTENTIALS; BRAIN-STEM; SENSITIVITY;
D O I
10.1016/j.heares.2024.109027
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong "polarity -order " effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.
引用
收藏
页数:13
相关论文
共 119 条
[1]   ECAP growth function to increasing pulse amplitude or pulse duration demonstrates large inter-animal variability that is reflected in auditory cortex of the guinea pig [J].
Adenis, Victor ;
Gourevitch, Boris ;
Mamelle, Elisabeth ;
Recugnat, Matthieu ;
Stahl, Pierre ;
Gnansia, Dan ;
Yann Nguyen ;
Edeline, Jean-Marc .
PLOS ONE, 2018, 13 (08)
[2]   A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise [J].
Arenberg, Julie G. ;
Parkinson, Wendy S. ;
Litvak, Leonid ;
Chen, Chen ;
Kreft, Heather A. ;
Oxenham, Andrew J. .
EAR AND HEARING, 2018, 39 (06) :1136-1145
[3]   The Intensity-pitch Relation Revisited: Monopolar Versus Bipolar Cochlear Stimulation [J].
Arnoldner, Christoph ;
Riss, Dorninik ;
Kaider, Alexandra ;
Mair, Alois ;
Wagenblast, Jens ;
Baumgartner, Wolf-Dieter ;
Gstoettner, Wolfgang ;
Hamzavi, Jafar-Sasan .
LARYNGOSCOPE, 2008, 118 (09) :1630-1636
[4]   Effect of reducing electrical stimulation rate on hearing performance of Nucleus® cochlear implant recipients [J].
Arora, Komal ;
Plant, Kerrie ;
Dawson, Pam ;
Cowan, Robert .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2025, 64 (02) :173-182
[5]   Robust Neuronal Discrimination in Primary Auditory Cortex Despite Degradations of Spectro-temporal Acoustic Details: Comparison Between Guinea Pigs with Normal Hearing and Mild Age-Related Hearing Loss [J].
Aushana, Yonane ;
Souffi, Samira ;
Edeline, Jean-Marc ;
Lorenzi, Christian ;
Huetz, Chlo .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (02) :163-180
[6]   Variations in Microanatomy of the Human Cochlea [J].
Avci, Ersin ;
Nauwelaers, Tim ;
Lenarz, Thomas ;
Hamacher, Volkmar ;
Kral, Andrej .
JOURNAL OF COMPARATIVE NEUROLOGY, 2014, 522 (14) :3245-3261
[7]   Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users [J].
Azadpour, Mahan ;
McKay, Colette M. ;
Svirsky, Mario A. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (03) :287-299
[8]   Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users: Intraoperative Recordings [J].
Bahmer, Andreas ;
Adel, Youssef ;
Baumann, Uwe .
OTOLOGY & NEUROTOLOGY, 2017, 38 (10) :E438-E444
[9]   The Underlying Mechanism of Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users Assessed With Objective Measure [J].
Bahmer, Andreas ;
Baumann, Uwe .
OTOLOGY & NEUROTOLOGY, 2016, 37 (09) :1231-1237
[10]   Auditory cortical images of cochlear-implant stimuli: Dependence on electrode configuration [J].
Bierer, JA ;
Middlebrooks, JC .
JOURNAL OF NEUROPHYSIOLOGY, 2002, 87 (01) :478-492