Long-Term Improvements in Glycemic Control with Dexcom CGM Use in Adults with Noninsulin-Treated Type 2 Diabetes

被引:8
|
作者
Layne, Jennifer E. [1 ]
Jepson, Lauren H. [1 ]
Carite, Alexander M. [1 ]
Parkin, Christopher G. [2 ]
Bergenstal, Richard M. [3 ]
机构
[1] Dexcom, 6340 Sequence Dr, San Diego, CA 92121 USA
[2] CGParkin Commun Inc, Henderson, NV USA
[3] HealthPartners Inst, Int Diabet Ctr, Minneapolis, MN USA
关键词
type; 2; diabetes; noninsulin; continuous glucose monitoring; time in range; time in tight range; INSULIN INJECTIONS; GLUCOSE; TIME; TECHNOLOGY; MANAGEMENT; RANGE;
D O I
10.1089/dia.2024.0197
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The objective of this real-world, observational study was to evaluate change in continuing glucose monitoring (CGM) metrics for 1 year after CGM initiation in adults with noninsulin-treated type 2 diabetes (T2D). Methods: Data were analyzed from Dexcom G6 and G7 users who self-reported: T2D, >= 18 years, gender, no insulin use, and had a baseline percent time in range (TIR) 70-180 mg/dL of <= 70%. Outcomes were change in CGM metrics from baseline to 6 and 12 months overall and for younger (<65 years) and older (>= 65 years) cohorts. Additional analyses explored the relationship between use of the high alert feature and change in TIR and time in tight range (TITR) 70-140 mg/dL. Results: CGM users (n = 3,840) were mean (SD) 52.5 (11.2) years, 47.9% female, mean TIR was 41.7% (21.4%), and 12.4% of participants were >= 65 years. Significant improvement in all CGM metrics not meeting target values at baseline was observed at 6 months, with continued improvement at 12 months. Mean baseline TIR increased by 17.3% (32.1%) from 41.7% (21.4%) to 59.0% (28.9%), and mean glucose management indicator decreased by 0.5% (1.2%) from 8.1% (0.9%) to 7.6% (1.1%) (both P < 0.001). Participants who maintained or customized the high alert default setting of 250 mg/dL had a greater increase in TIR and TITR compared with participants who disabled the alert. Days of CGM use over 12 months were high in 84.7% (15.9%). Conclusion: In this large, real-world study of adults with suboptimally controlled T2D not using insulin, Dexcom CGM use was associated with meaningful improvements in glycemic control over 12 months. Use of the high alert system feature was positively associated with glycemic outcomes. High use of CGM over 12 months suggests benefits related to consistent CGM use in this population.
引用
收藏
页码:925 / 931
页数:7
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring Systems in Noninsulin-Treated People with Type 2 Diabetes: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Ferreira, Rafael Oliva Morgado
    Trevisan, Talita
    Pasqualotto, Eric
    Chavez, Matheus Pedrotti
    Marques, Beatriz Friedrichsen
    Lamounier, Rodrigo Nunes
    van de Sande-Lee, Simone
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (04) : 252 - 262
  • [2] Intensive Structured Self-Monitoring of Blood Glucose and Glycemic Control in Noninsulin-Treated Type 2 Diabetes The PRISMA randomized trial
    Bosi, Emanuele
    Scavini, Marina
    Ceriello, Antonio
    Cucinotta, Domenico
    Tiengo, Antonio
    Marino, Raffaele
    Bonizzoni, Erminio
    Giorgino, Francesco
    DIABETES CARE, 2013, 36 (10) : 2887 - 2894
  • [3] Long-term benefits of insulin therapy and glycemic control in overweight and obese adults with type 2 diabetes
    Caballero, A. Enrique
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2009, 23 (02) : 143 - 152
  • [4] Self-monitoring of blood glucose in noninsulin-treated type 2 diabetes: an overview
    Kleefstra, Nanne
    Hortensius, Johanna
    van Hateren, Kornelis J. J.
    Logtenberg, Susan J. J.
    Houweling, Sebastiaan T.
    Gans, Rijk O. B.
    Bilo, Henk J. G.
    DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2009, 2 : 155 - 163
  • [5] Long-Term Effectiveness of Liraglutide for Weight Management and Glycemic Control in Type 2 Diabetes
    Mirabelli, Maria
    Chiefari, Eusebio
    Caroleo, Patrizia
    Arcidiacono, Biagio
    Corigliano, Domenica Maria
    Giuliano, Stefania
    Brunetti, Francesco Saverio
    Tanyolac, Sinan
    Foti, Daniela Patrizia
    Puccio, Luigi
    Brunetti, Antonio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (01)
  • [6] Continuous glucose monitoring (CGM) satisfaction and its effect on mental health and glycemic control in adults with type 1 diabetes
    Lukacs, Andrea
    Szerencsi, Laura Brigitta
    Barkai, Laszlo
    PHYSIOLOGY INTERNATIONAL, 2022, 109 (04) : 501 - 510
  • [7] Self-Monitoring of Blood Glucose in Noninsulin-treated Type 2 Diabetes Patients in the Valencia Community, Spain
    Cano-Blanquer, Diego
    Cervera-Casino, Pedro
    Peiro-Moreno, Salvador
    Mateu-Garcia, Monica
    Barreda-Aznar, Amparo
    REVISTA ESPANOLA DE SALUD PUBLICA, 2013, 87 (02): : 149 - 163
  • [8] Association of diabetes treatment with long-term glycemic patterns in patients with type 2 diabetes mellitus: A prospective cohort study
    Luo, Miyang
    Tan, Chuen Seng
    Lim, Wei Yen
    Chia, Kee Seng
    Tang, Wern Ee
    Tai, E. Shyong
    Venkataraman, Kavita
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2019, 35 (04)
  • [9] Long-Term Performance of Two Systems for Automated Insulin Delivery in Adults With Type 1 Diabetes: An Observational Study
    Fisker, Sanne
    Christensen, Mia
    Bach, Ermina
    Bibby, Bo Martin
    Hansen, Klavs Wuergler
    ENDOCRINOLOGY DIABETES & METABOLISM, 2025, 8 (03)
  • [10] Ketoacidosis at onset of type 1 diabetes is a predictor of long-term glycemic control
    Shalitin, Shlomit
    Fisher, Sharon
    Yackbovitch-Gavan, Michal
    de Vries, Liat
    Lazar, Liora
    Lebenthal, Yael
    Phillip, Moshe
    PEDIATRIC DIABETES, 2018, 19 (02) : 320 - 328