Data-driven diagnosis of high temperature PEM fuel cells based on the electrochemical impedance spectroscopy: Robustness improvement and evaluation

被引:5
|
作者
Yu, Dan [1 ]
Li, Xingjun [1 ,2 ]
Araya, Samuel Simon [3 ]
Sahlin, Simon Lennart [1 ]
Liso, Vincenzo [1 ]
机构
[1] Aalborg Univ, Dept Energy, DK-9220 Aalborg, Denmark
[2] Univ Texas Austin, Walker Dept Mech Engn, Austin, TX 78712 USA
[3] Luxembourg Inst Sci & Technol LIST, Mat Res & Technol Dev, L-4422 Belvaux, Luxembourg
来源
关键词
PEM fuel cell; Data-driven diagnosis; Robustness improvement and evaluation; Electrochemical impedance spectroscopy; FAULT-DIAGNOSIS; DEGRADATION; PREDICTION; BATTERIES; SYSTEM; STACK;
D O I
10.1016/j.jechem.2024.05.014
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Utilizing machine learning techniques for data-driven diagnosis of high temperature PEM fuel cells is beneficial and meaningful to the system durability. Nevertheless, ensuring the robustness of diagnosis remains a critical and challenging task in real application. To enhance the robustness of diagnosis and achieve a more thorough evaluation of diagnostic performance, a robust diagnostic procedure based on electrochemical impedance spectroscopy (EIS) and a new method for evaluation of the diagnosis robustness was proposed and investigated in this work. To improve the diagnosis robustness: (1) the degradation mechanism of different faults in the high temperature PEM fuel cell was first analyzed via the distribution of relaxation time of EIS to determine the equivalent circuit model (ECM) with better interpretability, simplicity and accuracy; (2) the feature extraction was implemented on the identified parameters of the ECM and extra attention was paid to distinguishing between the long-term normal degradation and other faults; (3) a Siamese Network was adopted to get features with higher robustness in a new embedding. The diagnosis was conducted using 6 classic classification algorithms-support vector machine (SVM), K-nearest neighbor (KNN), logistic regression (LR), decision tree (DT), random forest (RF), and Naive Bayes employing a dataset comprising a total of 1935 collected EIS. To evaluate the robustness of trained models: (1) different levels of errors were added to the features for performance evaluation; (2) a robustness coefficient (Roubust_C) was defined for a quantified and explicit evaluation of the diagnosis robustness. The diagnostic models employing the proposed feature extraction method can not only achieve the higher performance of around 100% but also higher robustness for diagnosis models. Despite the initial performance being similar, the KNN demonstrated a superior robustness after feature selection and re-embedding by triplet-loss method, which suggests the necessity of robustness evaluation for the machine learning models and the effectiveness of the defined robustness coefficient. This work hopes to give new insights to the robust diagnosis of high temperature PEM fuel cells and more comprehensive performance evaluation of the data-driven method for diagnostic application. (c) 2024 Published by ELSEVIER B.V. and Science Press on behalf of Science Press and Dalian Institute of Chemical Physics, Chinese Academy of Sciences. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:544 / 558
页数:15
相关论文
共 50 条
  • [1] Data-driven diagnosis of high temperature PEM fuel cells based on the electrochemical impedance spectroscopy: Robustness improvement and evaluation
    Dan Yu
    Xingjun Li
    Samuel Simon Araya
    Simon Lennart Sahlin
    Vincenzo Liso
    JournalofEnergyChemistry, 2024, 96 (09) : 544 - 558
  • [2] Electrochemical impedance spectroscopy (EIS) for PEM fuel cells
    Hunsom, Mali
    Spectroscopic Properties of Inorganic and Organometallic Compounds, 2012, 42 : 196 - 247
  • [3] TEMPERATURE SENSITIVITY ANALYSIS OF ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY RESULTS IN PEM FUEL CELLS
    Niya, Seyed Mohammad Rezaei
    Hoorfar, Mina
    PROCEEDINGS OF THE ASME 10TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2012, 2012, : 345 - 349
  • [4] High Frequency Artifacts in Electrochemical Impedance Spectroscopy Measurements on PEM Fuel Cells
    Cimenti, Massimiliano
    Tam, Mickey
    Stumper, Juergen
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2009, 12 (09) : B131 - B134
  • [5] Data-driven diagnosis of PEM fuel cell: A comparative study
    Li, Zhongliang
    Outbib, Rachid
    Hissel, Daniel
    Giurgea, Stefan
    CONTROL ENGINEERING PRACTICE, 2014, 28 : 1 - 12
  • [6] Rapid Fault Diagnosis of PEM Fuel Cells through Optimal Electrochemical Impedance Spectroscopy Tests
    Najafi, Behzad
    Bonomi, Paolo
    Casalegno, Andrea
    Rinaldi, Fabio
    Baricci, Andrea
    ENERGIES, 2020, 13 (14)
  • [7] Characterisation and Modelling of a High Temperature PEM Fuel Cell Stack using Electrochemical Impedance Spectroscopy
    Andreasen, S. J.
    Jespersen, J. L.
    Schaltz, E.
    Kaer, S. K.
    FUEL CELLS, 2009, 9 (04) : 463 - 473
  • [8] Spatially Resolved Electrochemical Impedance Spectroscopy of Automotive PEM Fuel Cells
    Haimerl, Felix
    Sabawa, Jarek P.
    Dao, Tuan A.
    Bandarenka, Aliaksandr S.
    CHEMELECTROCHEM, 2022, 9 (10):
  • [9] Diagnosis of PEM Fuel Cell System Based on Electrochemical Impedance Spectroscopy and Deep Learning Method
    Lv, Jianfeng
    Kuang, Jiyuan
    Yu, Zhongliang
    Sun, Guanghui
    Liu, Jianxing
    Leon, Jose I.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (01) : 657 - 666
  • [10] Use of Electrochemical Impedance Spectroscopy for the Evaluation of Performance of PEM Fuel Cells Based on Carbon Cloth Gas Diffusion Electrodes
    Latorrata, Saverio
    Pelosato, Renato
    Stampino, Paola Gallo
    Cristiani, Cinzia
    Dotelli, Giovanni
    JOURNAL OF SPECTROSCOPY, 2018, 2018