Is day-case surgical procedure safe for MICRA leadless pacemaker implantation?

被引:2
作者
Toon, Lin-Thiri [1 ,2 ]
Elrefai, Mohammed [1 ]
Abouelasaad, Mohamed [1 ]
Patil, Roopa [1 ]
Paisey, John [1 ]
Yue, Arthur [1 ]
Roberts, Paul [1 ,2 ]
机构
[1] Univ Hosp Southampton NHS Fdn Trust, Cardiac Rhythm Management Res Dept, Tremona Rd, Southampton SO16 6YD, England
[2] Univ Southampton, Southampton, England
关键词
MICRA; Pacemaker; Patient management; Day-case surgery;
D O I
10.1007/s10840-024-01907-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background MICRA implantation is not commonly done as a day-case procedure. Elective leadless pacemakers are implanted routinely in our centre. Objective To assess whether the day-case MICRA procedure is safe. Methods We retrospectively collected data from all patients undergoing elective MICRA implantation at our centre between May 2014 and Nov 2022 (n = 81). Two patient groups were stratified: those planned to be discharged on the same day (SD, n = 52) and those planned to be observed overnight after the procedure (ON, n = 29). Patient demographics, size of the sheath used, type of MICRA device, and rate of complications were recorded. In patients with successful implants (n = 80), device function at discharge and first routine follow-up were evaluated. Results There were 58% males in the SD group and 45% in the ON group. Median age was 49 years in the SD and 67 years in the ON. Among patients who were planned as a day case, 8 patients had to stay in the hospital but for < 48 h: 2 due to minor groin bleeding, 1 due to patient's request despite fit to discharge, 4 due to the procedure carried out later in the day, and 1 for observation due to procedural complexity. MICRA implantation was successful in 80 patients. The rate of the major complications was 2% in the SD group and 7% in the ON group (p = 0.223), and none of the co-morbidities assessed showed an association with any complications. Device parameters at the follow-up were available in 76 patients. The rate of patients with low and stable PCT at follow-up was also 98% in the SD group and 96% in the ON group. Conclusions Day case MICRA procedure can be performed safely in an appropriately selected patient population.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 11 条
[1]  
[Anonymous], OVERVIEW LEADLESS CA
[2]   Day case surgery: a good news story for the NHS [J].
Appleby, John .
BMJ-BRITISH MEDICAL JOURNAL, 2015, 351
[3]   Feasibility and Safety of Same-Day Discharge after Implantable Cardioverter Defibrillator Placement for Primary Prevention [J].
Darda, Saba ;
Khouri, Yazan ;
Gorges, Rony ;
Al Samara, Mershed ;
Jain, Sachin K. Amruthlal ;
Daccarett, Marcos ;
Machado, Christian .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (07) :885-891
[4]   Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control [J].
El-Chami, Mikhael F. ;
Al-Samadi, Faisal ;
Clementy, Nicolas ;
Garweg, Christophe ;
Luis Martinez-Sande, Jose ;
Piccini, Jonathan P. ;
Iacopino, Saverio ;
Lloyd, Michael ;
Vinolas Prat, Xavier ;
Jacobsen, Michael Dilou ;
Ritter, Philippe ;
Johansen, Jens Brock ;
Tondo, Claudio ;
Liu, Fang ;
Fagan, Dedra H. ;
Eakley, Alyssa K. ;
Roberts, Paul R. .
HEART RHYTHM, 2018, 15 (12) :1800-1807
[5]  
Kiani Soroosh, 2019, J Atr Fibrillation, V12, P2153, DOI 10.4022/jafib.2153
[6]   The 11th World Survey of Cardiac Pacing and Implantable Cardioverter-Defibrillators: Calendar Year 2009-A World Society of Arrhythmia's Project [J].
Mond, Harry G. ;
Proclemer, Alessandro .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (08) :1013-1027
[7]   Safety and Cost-Effectiveness of Same Day Permanent Pacemaker Implantation [J].
Osman, Faizel ;
Krishnamoorthy, Suresh ;
Nadir, Adnan ;
Mullin, Phillip ;
Morley-Davies, Adrian ;
Creamer, John .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03) :383-385
[8]   Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker [J].
Reddy, Vivek Y. ;
Exner, Derek V. ;
Cantillon, Daniel J. ;
Doshi, Rahul ;
Bunch, T. Jared ;
Tomassoni, Gery F. ;
Friedman, Paul A. ;
Estes, N. A. Mark, III ;
Ip, John ;
Niazi, Imran ;
Plunkitt, Kenneth ;
Banker, Rajesh ;
Porterfield, James ;
Ip, James E. ;
Dukkipati, Srinivas R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (12) :1125-1135
[9]   A Leadless Intracardiac Transcatheter Pacing System [J].
Reynolds, Dwight ;
Duray, Gabor Z. ;
Omar, Razali ;
Soejima, Kyoko ;
Neuzil, Petr ;
Zhang, Shu ;
Narasimhan, Calambur ;
Steinwender, Clemens ;
Brugada, Josep ;
Lloyd, Michael ;
Roberts, Paul R. ;
Sagi, Venkata ;
Hummel, John ;
Bongiorni, Maria Grazia ;
Knops, Reinoud E. ;
Ellis, Christopher R. ;
Gornick, Charles C. ;
Bernabei, Matthew A. ;
Laager, Verla ;
Stromberg, Kurt ;
Williams, Eric R. ;
Hudnall, J. Harrison ;
Ritter, Philippe .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (06) :533-541
[10]   Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study [J].
Ritter, Philippe ;
Duray, Gabor Z. ;
Steinwender, Clemens ;
Soejima, Kyoko ;
Omar, Razali ;
Mont, Lluis ;
Boersma, Lucas V. A. ;
Knops, Reinoud E. ;
Chinitz, Larry ;
Zhang, Shu ;
Narasimhan, Calambur ;
Hummel, John ;
Lloyd, Michael ;
Simmers, Timothy Alexander ;
Voigt, Andrew ;
Laager, Verla ;
Stromberg, Kurt ;
Bonner, Matthew D. ;
Sheldon, Todd J. ;
Reynolds, Dwight ;
Kypta, Alexander ;
Vamos, Mate ;
Bordachar, Pierre ;
El Chami, Mikhael ;
Hussin, Azlan ;
Mont Girbau, Josep Lluis ;
Roberts, Paul ;
De Groot, Joris R. ;
Tjong, Fleur V. Y. ;
Sato, Toshiaki ;
Bongiorni, Maria Grazia ;
Soldati, Ezio ;
Hummel, John ;
Love, Charles ;
Neuzil, Petr ;
Reddy, Vivek ;
Bracke, Frank A. L. E. ;
Sagi, Venkata ;
Lee, Scott ;
Gornick, Charles ;
Remole, Stephen ;
Sra, Jasbir ;
Nangia, Vikram ;
Shehata, Michael ;
Swerdlow, Charles ;
Schoenhard, John ;
Milstein, Simon ;
Saba, Samir ;
Bernabei, Matthew ;
Bansal, Sandeep .
EUROPEAN HEART JOURNAL, 2015, 36 (37) :2510-2519