Development and optimisation of a near-infrared spectroscopic system for glucose quantification in aqueous and intralipid-based samples

被引:0
作者
Davison, Nicholas B. [1 ]
Gaffney, Christopher J. [1 ]
Kerns, Jemma G. [1 ]
Zhuang, Qiandong [2 ]
机构
[1] Univ Lancaster, Lancaster Med Sch, Lancaster LA1 4AT, England
[2] Univ Lancaster, Phys Dept, Lancaster LA1 4YW, England
来源
ENGINEERING RESEARCH EXPRESS | 2024年 / 6卷 / 02期
关键词
near infrared spectroscopy; glucose monitoring; non-invasive sensing; optical system design; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-GLUCOSE; SCATTERING PROPERTIES; 1ST OVERTONE; HUMAN SKIN; TISSUE; LIGHT; COMBINATION; LIMITATIONS; REGRESSION;
D O I
10.1088/2631-8695/ad4aed
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A non-invasive glucose sensing device could revolutionise diabetes treatment. Near Infrared (NIR) spectroscopy is a promising technology for glucose sensing; however, the design and choice of components for NIR spectroscopy can greatly affect the sensing accuracy. We aimed to develop a NIR absorption spectroscopy system to determine liquid glucose concentrations in the physiological range, by evaluating a range of NIR photodetector components and light sources. Three detection assemblies were tested: (i) a dispersive spectrometer with photodiode array, (ii) a Czerny-Turner monochromator with InGaAs photodiode and (iii) a miniature Fourier Transform Infrared (FTIR) spectrometer. A halogen lamp and NIR globar were trialled as potential light sources. The components were systematically tested by comparing the coefficient of determination and standard error of prediction (SEP) for the same set of aqueous glucose samples through 10 mmol l-1 concentration steps. The Czerny-Turner monochromator with InGaAs photodiode, along with the globar, were identified as the optimal components for the system. A range of concentration steps (1-10 mmol l-1) were scanned to identify the physiologically relevant limit of detection, which was identified as 5 mmol/l for glucose in solution. Spectra were then collected from glucose samples in 10% intralipid suspension in the 10-20 mmol l-1 range and the equivalent concentrations in solution. The SEP was greater for the intralipid samples due to strong scattering. Scattering was dominant above 1300 nm, whilst absorption was dominant below 1300 nm. Although alternative approaches achieve better resolution, our system uses simple and readily-available components and presents a platform for a non-invasive NIR glucose sensing device.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Near-infrared spectroscopic quantification of changes in the concentration of oxidized cytochrome c oxidase in the healthy human brain during hypoxemia
    National Hospital for Neurology and Neurosurgery, Department of Neuroanaesthesia and Neurocritical Care, Queen Square, London WC1N 3BG, United Kingdom
    不详
    [J]. J Biomed Opt, 2007, 2
  • [42] Near-infrared spectroscopic quantification of changes in the concentration of oxidized cytochrome c oxidase in the healthy human brain during hypoxemia
    Tisdall, Martin M.
    Tachtsidis, Ilias
    Leung, Terence S.
    Elwell, Clare E.
    Smith, Martin
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)
  • [43] Comparison of Multivariate Regression Models Based on Water- and Carbohydrate-Related Spectral Regions in the Near-Infrared for Aqueous Solutions of Glucose
    Beganovic, Anel
    Moll, Vanessa
    Huck, Christian W.
    [J]. MOLECULES, 2019, 24 (20):
  • [44] Classification and quantification of adulterants in Alaska pollock based on fourier transform near-infrared spectroscopy with chemometrics
    Feng, Shijia
    Qi, Shou
    Chen, Chen
    Khan, Imran Mahmood
    Gu, Qianhui
    Zhang, Yin
    Wang, Zhouping
    [J]. FOOD BIOSCIENCE, 2024, 59
  • [45] Non-invasive Self Monitoring of Blood Glucose System Using Near-infrared Spectroscopy
    Yoshinari, Hiroki
    Ishizawa, Hiroaki
    Fukuda, Masaya
    Tokutake, Shota
    Koyama, Shouhei
    Miyauchi, Yuki
    [J]. 2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 1852 - 1854
  • [46] Random forest as a potential multivariate method for near-infrared (NIR) spectroscopic analysis of complex mixture samples: Gasoline and naphtha
    Lee, Sanguk
    Choi, Hangseok
    Cha, Kyungjoon
    Chung, Hoeil
    [J]. MICROCHEMICAL JOURNAL, 2013, 110 : 739 - 748
  • [47] The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration
    Movilla-Meza, Nathaly A.
    Sierra-Vega, Nobel O.
    Alvarado-Hernandez, Barbara B.
    Mendez, Rafael
    Romanach, Rodolfo J.
    [J]. PHARMACEUTICAL RESEARCH, 2023, 40 (12) : 2903 - 2916
  • [48] The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration
    Nathaly A. Movilla-Meza
    Nobel O. Sierra-Vega
    Bárbara B. Alvarado-Hernández
    Rafael Méndez
    Rodolfo J. Romañach
    [J]. Pharmaceutical Research, 2023, 40 : 2903 - 2916
  • [49] Double-beam near-infrared spectroscopy to correct light source drift in aqueous glucose solution experiments
    Min, Xiaolin
    Liu, Rong
    Hu, Yongxiang
    Fu, Bo
    Xu, Kexin
    [J]. ANALYTICAL METHODS, 2014, 6 (24) : 9831 - 9840
  • [50] Development of non-invasive blood glucose regression based on near-infrared spectroscopy combined with a deep-learning method
    Wang, Zhuyu
    Zhou, Linhua
    Liu, Tianqing
    Huan, Kewei
    Jia, Xiaoning
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (21)