Development and optimisation of a near-infrared spectroscopic system for glucose quantification in aqueous and intralipid-based samples

被引:0
作者
Davison, Nicholas B. [1 ]
Gaffney, Christopher J. [1 ]
Kerns, Jemma G. [1 ]
Zhuang, Qiandong [2 ]
机构
[1] Univ Lancaster, Lancaster Med Sch, Lancaster LA1 4AT, England
[2] Univ Lancaster, Phys Dept, Lancaster LA1 4YW, England
来源
ENGINEERING RESEARCH EXPRESS | 2024年 / 6卷 / 02期
关键词
near infrared spectroscopy; glucose monitoring; non-invasive sensing; optical system design; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-GLUCOSE; SCATTERING PROPERTIES; 1ST OVERTONE; HUMAN SKIN; TISSUE; LIGHT; COMBINATION; LIMITATIONS; REGRESSION;
D O I
10.1088/2631-8695/ad4aed
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A non-invasive glucose sensing device could revolutionise diabetes treatment. Near Infrared (NIR) spectroscopy is a promising technology for glucose sensing; however, the design and choice of components for NIR spectroscopy can greatly affect the sensing accuracy. We aimed to develop a NIR absorption spectroscopy system to determine liquid glucose concentrations in the physiological range, by evaluating a range of NIR photodetector components and light sources. Three detection assemblies were tested: (i) a dispersive spectrometer with photodiode array, (ii) a Czerny-Turner monochromator with InGaAs photodiode and (iii) a miniature Fourier Transform Infrared (FTIR) spectrometer. A halogen lamp and NIR globar were trialled as potential light sources. The components were systematically tested by comparing the coefficient of determination and standard error of prediction (SEP) for the same set of aqueous glucose samples through 10 mmol l-1 concentration steps. The Czerny-Turner monochromator with InGaAs photodiode, along with the globar, were identified as the optimal components for the system. A range of concentration steps (1-10 mmol l-1) were scanned to identify the physiologically relevant limit of detection, which was identified as 5 mmol/l for glucose in solution. Spectra were then collected from glucose samples in 10% intralipid suspension in the 10-20 mmol l-1 range and the equivalent concentrations in solution. The SEP was greater for the intralipid samples due to strong scattering. Scattering was dominant above 1300 nm, whilst absorption was dominant below 1300 nm. Although alternative approaches achieve better resolution, our system uses simple and readily-available components and presents a platform for a non-invasive NIR glucose sensing device.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Modeling of Diffuse Reflectance Near-infrared Spectroscopy Based System for Noninvasive Tissue Glucose Level Measuring
    Litinskaia, Evgeniia L.
    Mikhailov, Mikhail O.
    Polyakova, Elizaveta A.
    Pozhar, Kirill, V
    PROCEEDINGS OF THE 2021 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (ELCONRUS), 2021, : 2818 - 2822
  • [22] Development of optimal protocol for visible and near-infrared reflectance spectroscopic evaluation of meat quality
    Shackelford, SD
    Wheeler, TL
    Koohmaraie, M
    MEAT SCIENCE, 2004, 68 (03) : 371 - 381
  • [23] Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy
    Chung, H
    Arnold, MA
    Rhiel, M
    Murhammer, DW
    APPLIED SPECTROSCOPY, 1996, 50 (02) : 270 - 276
  • [24] Floating reference position-based correction method for near-infrared spectroscopy in long-term glucose concentration monitoring
    Han, Guang
    Han, Tongshuai
    Xu, Kexin
    Liu, Jin
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (07)
  • [25] Near-infrared spectroscopic sensing system for online monitoring of milk quality during milking
    Shuso Kawamura
    Masataka Kawasaki
    Hiroki Nakatsuji
    Motoyasu Natsuga
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (1): : 37 - 43
  • [26] Raman and near-infrared spectroscopy for quantification of fat composition in a complex food model system
    Afseth, NK
    Segtnan, VH
    Marquardt, BJ
    Wold, JP
    APPLIED SPECTROSCOPY, 2005, 59 (11) : 1324 - 1332
  • [27] Development of sorting system based on potato starch content using visible and near-infrared spectroscopy
    Komiyama, Seiichi
    Kato, Jun
    Honda, Hiroyuki
    Matsushima, Katsuyuki
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 2007, 54 (06): : 304 - 309
  • [28] Near-infrared LED based Non-invasive Blood Glucose Sensor
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 591 - 594
  • [29] Subspace Regression Ensemble Method Based on Variable Clustering for Near-Infrared Spectroscopic Calibration
    Tan, Chao
    Qin, Xin
    Li, Menglong
    ANALYTICAL LETTERS, 2009, 42 (11) : 1693 - 1710
  • [30] Research on nonlinear quantification of Rebaudioside A crystallization process based on near-infrared sensor fusion
    Hailing Dong
    Ruiqi Huang
    Lele Gao
    Yan Yang
    Xiuhua Xu
    Lei Nie
    Lian Li
    Qin Dong
    Hui Zhang
    Jinke Xu
    Jing Sun
    Hengchang Zang
    Journal of Pharmaceutical Innovation, 2023, 18 : 735 - 746