Development and optimisation of a near-infrared spectroscopic system for glucose quantification in aqueous and intralipid-based samples

被引:0
|
作者
Davison, Nicholas B. [1 ]
Gaffney, Christopher J. [1 ]
Kerns, Jemma G. [1 ]
Zhuang, Qiandong [2 ]
机构
[1] Univ Lancaster, Lancaster Med Sch, Lancaster LA1 4AT, England
[2] Univ Lancaster, Phys Dept, Lancaster LA1 4YW, England
来源
ENGINEERING RESEARCH EXPRESS | 2024年 / 6卷 / 02期
关键词
near infrared spectroscopy; glucose monitoring; non-invasive sensing; optical system design; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-GLUCOSE; SCATTERING PROPERTIES; 1ST OVERTONE; HUMAN SKIN; TISSUE; LIGHT; COMBINATION; LIMITATIONS; REGRESSION;
D O I
10.1088/2631-8695/ad4aed
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A non-invasive glucose sensing device could revolutionise diabetes treatment. Near Infrared (NIR) spectroscopy is a promising technology for glucose sensing; however, the design and choice of components for NIR spectroscopy can greatly affect the sensing accuracy. We aimed to develop a NIR absorption spectroscopy system to determine liquid glucose concentrations in the physiological range, by evaluating a range of NIR photodetector components and light sources. Three detection assemblies were tested: (i) a dispersive spectrometer with photodiode array, (ii) a Czerny-Turner monochromator with InGaAs photodiode and (iii) a miniature Fourier Transform Infrared (FTIR) spectrometer. A halogen lamp and NIR globar were trialled as potential light sources. The components were systematically tested by comparing the coefficient of determination and standard error of prediction (SEP) for the same set of aqueous glucose samples through 10 mmol l-1 concentration steps. The Czerny-Turner monochromator with InGaAs photodiode, along with the globar, were identified as the optimal components for the system. A range of concentration steps (1-10 mmol l-1) were scanned to identify the physiologically relevant limit of detection, which was identified as 5 mmol/l for glucose in solution. Spectra were then collected from glucose samples in 10% intralipid suspension in the 10-20 mmol l-1 range and the equivalent concentrations in solution. The SEP was greater for the intralipid samples due to strong scattering. Scattering was dominant above 1300 nm, whilst absorption was dominant below 1300 nm. Although alternative approaches achieve better resolution, our system uses simple and readily-available components and presents a platform for a non-invasive NIR glucose sensing device.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effect of sample complexity on quantification of analytes in aqueous samples by near-infrared spectroscopy
    Riley, MR
    Arnold, MA
    Murhammer, DW
    APPLIED SPECTROSCOPY, 2000, 54 (02) : 255 - 261
  • [2] Accuracy of Noninvasive Glucose Sensing Based on Near-Infrared Spectroscopy
    Liu, Jin
    Liu, Rong
    Xu, Kexin
    APPLIED SPECTROSCOPY, 2015, 69 (11) : 1313 - 1318
  • [3] Selectivity and Sensitivity of Near-Infrared Spectroscopic Sensing of β-Hydroxybutyrate, Glucose, and Urea in Ternary Aqueous Solutions
    Ye, Maosong
    Arnold, Mark A.
    ANALYTICAL CHEMISTRY, 2021, 93 (13) : 5586 - 5595
  • [4] Determination of organic contaminants in aqueous samples by near-infrared spectroscopy
    Ding, Q
    Boyd, BL
    Small, GW
    APPLIED SPECTROSCOPY, 2000, 54 (07) : 1047 - 1054
  • [5] Method development and validation of a near-infrared spectroscopic method for in-line API quantification during fluidized bed granulation
    Zhong, Liang
    Gao, Lele
    Li, Lian
    Nei, Lei
    Wei, Yongheng
    Zhang, Kefan
    Zhang, Hui
    Yin, Wenping
    Xu, Dongbo
    Zang, Hengchang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 274
  • [6] Development of a near-infrared spectroscopic system for monitoring urine glucose level for the use of long-term home healthcare
    Tanaka, Shinobu
    Hayakawa, Yuuto
    Ogawa, Mitsuhiro
    Yamakoshi, Ken-ichi
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [7] Classification of Near-infrared Spectroscopic Glucose Concentrations Using Convolutional Neural Network
    Mekonnen, Bitewulign Kassa
    Yang, Webb
    Hsieh, Tung-Han
    Liaw, Shien-Kuei
    Yang, Fu-Liang
    2020 OPTO-ELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC 2020), 2020,
  • [8] Quantification of anomeric structural changes of glucose solutions using near-infrared spectra
    Tanaka, Sae
    Kojic, Dusan
    Tsenkova, Roumiana
    Yasui, Masato
    CARBOHYDRATE RESEARCH, 2018, 463 : 40 - 46
  • [9] DISCRETE WAVELENGTHS SCREENING METHOD FOR THE NEAR-INFRARED SPECTROSCOPIC ANALYSIS OF SERUM GLUCOSE
    Lin, Yucai
    Chen, Jiemei
    Pan, Tao
    2019 10TH WORKSHOP ON HYPERSPECTRAL IMAGING AND SIGNAL PROCESSING - EVOLUTION IN REMOTE SENSING (WHISPERS), 2019,
  • [10] A Combined Near-Infrared and Mid-Infrared Spectroscopic Approach for the Detection and Quantification of Glycine in Human Serum
    Veettil, Thulya Chakkumpulakkal Puthan
    Wood, Bayden R.
    SENSORS, 2022, 22 (12)