Design and fabrication of machine learning trained silver nanoparticles-infused multi-walled carbon nanotube-based sensor for antiviral drug monitoring

被引:4
|
作者
Fatima, Mehvish [1 ]
Hanif, Sehrish [1 ]
Elsharkawy, Eman Ramadan [2 ]
Zafar, Farhan [3 ]
Zulfiqar, Anam [4 ]
Khan, Muhammad Ali [1 ]
Akhtar, Naeem [1 ]
Fareed, Zainab [1 ]
El-Bahy, Zeinhom M. [5 ]
Shafiq, Zahid [1 ]
Yu, Cong [6 ]
机构
[1] Bahauddin Zakariya Univ BZU, Inst Chem Sci, Multan 60800, Pakistan
[2] Northern Border Univ, Fac Sci, Dept Chem, Ar Ar, Saudi Arabia
[3] COMSATS Univ Islamabad, Dept Chem, Lahore Campus, Lahore 54000, Pakistan
[4] Bahauddin Zakariya Univ BZU, Dept Biochem, Multan 60800, Pakistan
[5] Al Azhar Univ, Fac Sci, Dept Chem, Nasr City 11884, Cairo, Egypt
[6] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
关键词
Acyclovir; Antiviral drug; Machine learning; Polydopamine; Silver nanoparticles; Multiwalled carbon nanotubes; ACYCLOVIR;
D O I
10.1016/j.microc.2024.110921
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acyclovir (ACY), an antiviral drug, has been predominantly used to treat herpes simplex and zoster infections. Despite its therapeutic benefits, its precise monitoring is very vital because its usage may lead to a wide range of adverse effects, including neurotoxicity, urticaria, malaise, and nephrotoxicity. To fulfil this demand, herein we reported the fabrication of silver (Ag) nanoparticles infused multi-walled carbon nanotubes (MWCNTs) based on a novel sensor for the precise monitoring of ACY. Ag nanoparticles were uniformly infused over the surface of MWCNTs through polydopamine (PDA) functionalization. Additionally, we have trained ML algorithms on our experimental dataset to optimize, predict and validate ACY voltametric current response as function of material concentration, drying time and pH. ML has simplified the experimental procedures and improved the electrooxidation of ACY by optimized experimental parameters. Briefly, our results demonstrated that the designed Ag/ PDA-MWCNTs-based sensor shows efficient electrooxidation of ACY with reliable linear response (5-290 nM), high sensitivity (2.8796 mu A nM-1), low detection limit (2.7408 nM) and high selectivity even in the presence of co-existing interferences. The efficient electrocatalytic activity of the designed sensor could be attributed to the high surface area of the MWCNTs along with homogeneous distribution of Ag nanoparticles through PDA functionalization. The designed electrode further displayed reliable reproducibility and reusability against ACY even in real urine samples. To the best of our knowledge, this is the first study of using ML optimized Ag/PDAMWCNTs based sensor for electrochemical monitoring of ACY.
引用
收藏
页数:10
相关论文
共 37 条
  • [31] Flexible piezoelectric sensor based on polyvinylidene fluoride/polyacrylonitrile/carboxy-terminated multi-walled carbon nanotube composite films for human motion monitoring
    Huang, Yan
    Li, Yi
    Yang, Yanxin
    Wu, Yibo
    Shi, Qisong
    NANOTECHNOLOGY, 2024, 35 (23)
  • [32] Solution-gated graphene transistor based sensor for histamine detection with gold nanoparticles decorated graphene and multi-walled carbon nanotube functionalized gate electrodes
    Wang, Rongrong
    Mao, Yu
    Wang, Lu
    Qu, Hao
    Chen, Ying
    Zheng, Lei
    FOOD CHEMISTRY, 2021, 347
  • [33] A Core-Shell Au@TiO2 and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H2O2 in Human Blood Serum and Saliva
    Saeed, Ayman Ali
    Abbas, Mohammed Nooredeen
    El-Hawary, Waheed Fathi
    Issa, Yousry Moustafa
    Singh, Baljit
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [34] A Machine Learning Assisted Non-Enzymatic Electrochemical Biosensor to Detect Urea Based on Multi-Walled Carbon Nanotube Functionalized with Copper Oxide Micro-Flowers
    Zalke, Jitendra B.
    Bhaiyya, Manish L.
    Jain, Pooja A.
    Sakharkar, Devashree N.
    Kalambe, Jayu
    Narkhede, Nitin P.
    Thakre, Mangesh B.
    Rotake, Dinesh R.
    Kulkarni, Madhusudan B.
    Singh, Shiv Govind
    BIOSENSORS-BASEL, 2024, 14 (10):
  • [35] pH-sensitive nanocarrier based on gold/silver core-shell nanoparticles decorated multi-walled carbon manotubes for tracing drug release in living cells
    Chen, Peng
    Wang, Zhuyuan
    Zong, Shenfei
    Zhu, Dan
    Chen, Hui
    Zhang, Yizhi
    Wu, Lei
    Cui, Yiping
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 446 - 451
  • [36] Development of low-cost hybrid multi-walled carbon nanotube-based ammonia gas-sensing strips with an integrated sensor read-out system for clinical breath analyzer applications
    Abdulla, Sukhananazerin
    Dhakshinamoorthy, Jayaseelan
    Mohan, Vijay
    Ponnuvelu, Dinesh Veeran
    Kallidaikuruchi, Venkataraman Krishnan
    Thalakkotil, Lazar Mathew
    Pullithadathil, Biji
    JOURNAL OF BREATH RESEARCH, 2019, 13 (04)
  • [37] A highly sensitive non-enzymatic glucose sensor based on a simple two-step electrodeposition of cupric oxide (CuO) nanoparticles onto multi-walled carbon nanotube arrays
    Yang, Jiang
    Jiang, Liao-Chuan
    Zhang, Wei-De
    Gunasekaran, Sundaram
    TALANTA, 2010, 82 (01) : 25 - 33