Introduction of a spectrophotometric method for salivary iodine determination on microplate based on Sandell-Kolthoff reaction

被引:1
|
作者
Oblak, Adrijana [1 ,2 ]
Imperl, Jernej [3 ]
Kolar, Mitja [3 ]
Marolt, Gregor [3 ]
Krhin, Blaz [1 ]
Zaletel, Katja [1 ,2 ]
Gaberscek, Simona [1 ,2 ]
机构
[1] Univ Med Ctr Ljubljana, Div Nucl Med, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[3] Univ Ljubljana, Fac Chem & Chem Technol, Ljubljana, Slovenia
关键词
iodine; salivary iodine concentration; Sandell-Kolthoff reaction; Inductively Coupled Plasma Mass Spectrometry; URINARY; SYMPORTER; TISSUES; GLAND;
D O I
10.2478/raon-2024-0035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Iodine is an essential element for the synthesis of thyroid hormones. Therefore, a reliable marker of iodine supply is important. Iodine is predominantly excreted via kidneys, but also via salivary glands. Our aim was to introduce a new and simple method for determination of salivary iodine concentration (SLIC). Materials and methods. Self-prepared chemicals and standards for Sandell-Kolthoff reaction on microplate with ammonium peroxydisulfate (AP) in the range 0-400 mu g/L were used. Suitability of water-based standards (WBS) and artificial saliva-based standards (ASS) for standard curve were tested. We followed standards for method validation, defined concentration of used AP and compared our results with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results. WBS gave more reliable results than ASS as an underestimation of iodine concentration was found for ASS. LoB was 6.5 mu g/L, LoD 12.0 mu g/L, therefore analytical range was 12-400 mu g/L. Intra- and inter-assay imprecisions at iodine concentrations, namely 20, 100, 165, and 350 mu g/L were 18.4, 5.1, 5.7, and 2.8%, respectively, and 20.7, 6.7, 5.1, and 4.3%, respectively. Suitable molarity of AP was 1.0 mol/L and showed no difference to 1.5 mol/L (P values for samples with concentration 40, 100, and 150 mu g/L, were 0.761, 0.085, and 0.275, respectively), whereas there was a significant change using 0.5 mol/L (P<0.001). Saliva samples could be diluted up to 1:8. There was no interference of thiocyanate and caffeine up to 193.5 mg/L. Our original method was comparable to ICP-MS. Spaerman coefficient was 0.989 (95% CI: 0.984-0.993). Conclusions. The new method for SLIC determination is in excellent agreement with ICP-MS and easy-to-use.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 24 条
  • [1] Validation of a Spectrophotometric Method for Urinary Iodine Determination on Microplate Based on Sandell-Kolthoff Reaction
    Oblak, Adrijana
    Arohonka, Petra
    Erlund, Iris
    Kuzmanovska, Sonja
    Zaletel, Katja
    Gaberscek, Simona
    LABORATORY MEDICINE, 2022, 53 (04) : 376 - 380
  • [2] Improvement of the Sandell-Kolthoff reaction method (ammonium persulfate digestion) for the determination of iodine in urine samples
    Machado, Ana
    Lima, Lurdes
    Mesquita, Raquel B. R.
    Bordalo, Adriano A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (09) : E206 - E208
  • [3] Interference of preservatives on urinary iodine measurement by Sandell-Kolthoff method
    Kaya, Elif
    Usta, Murat
    Emecen, Omer
    Yildirmak, Sembol
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2022, 82 (06) : 498 - 503
  • [4] Spectrophotometric determination of urinary iodine by the Sandell-Kolthoff reaction subsequent to dry alkaline ashing.: Results from the Czech Republic in the period 1994-2002
    Bílek, R
    Bednár, J
    Zamrazil, V
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (06) : 573 - 580
  • [5] Kinetic determination of iodide by the Sandell-Kolthoff reaction using diphenylamine-4-sulfonic acid
    Trokhimenko, OM
    Zaitsev, VN
    JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 59 (05) : 491 - 494
  • [6] Concentration-dependent Differences in Urinary Iodine Measurements Between Inductively Coupled Plasma Mass Spectrometry and the Sandell-Kolthoff Method
    Li, Yongze
    Ding, Shuangning
    Han, Cheng
    Liu, Aihua
    Shan, Zhongyan
    Teng, Weiping
    Mao, Jinyuan
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2021, 199 (07) : 2489 - 2495
  • [7] Concentration-dependent Differences in Urinary Iodine Measurements Between Inductively Coupled Plasma Mass Spectrometry and the Sandell-Kolthoff Method
    Yongze Li
    Shuangning Ding
    Cheng Han
    Aihua Liu
    Zhongyan Shan
    Weiping Teng
    Jinyuan Mao
    Biological Trace Element Research, 2021, 199 : 2489 - 2495
  • [8] Kinetic Determination of Iodide by the Sandell–Kolthoff Reaction Using Diphenylamine-4-Sulfonic Acid
    O. M. Trokhimenko
    V. N. Zaitsev
    Journal of Analytical Chemistry, 2004, 59 : 491 - 494
  • [9] A simple and sensitive spectrophotometric method for the determination of iodine in environmental samples
    Kesari, R
    Rastogi, R
    Gupta, VK
    CHEMIA ANALITYCZNA, 1998, 43 (02): : 201 - 207
  • [10] Spectrophotometric determination of iodine by iodine starch method in urine samples after alkaline ashing
    Divrikli, Ü
    Soylak, M
    Dogan, M
    CHEMIA ANALITYCZNA, 2000, 45 (02): : 257 - 264