Methodological Validation of Sedimentation Velocity Analytical Ultracentrifugation Method for Adeno-Associated Virus and Collaborative Calibration of System Suitability Substance

被引:0
|
作者
Qin, Xi [1 ]
Yu, Qikun [2 ]
Li, Xiang [1 ]
Jiang, Wei [3 ]
Shi, Xinchang [1 ]
Hou, Wenxiu [3 ]
Zhang, Da [4 ]
Cai, Zhenzhen [3 ]
Bi, Hua [1 ]
Fan, Wenhong [1 ]
Ding, Youxue [1 ]
Yang, Yichen [2 ]
Dong, Biao [5 ]
Chen, Long [6 ]
Huo, Dehua [2 ]
Wang, Cong [2 ]
Zhou, Yong [1 ]
Pei, Dening [1 ]
Ye, Miao [2 ]
Liang, Chenggang [1 ]
机构
[1] Natl Inst Food & Drug Control, 2 Tiantan Xili, Beijing, Peoples R China
[2] Beckman Coulter Inc, Shanghai, Peoples R China
[3] Belief Biomed Inc, Shanghai, Peoples R China
[4] Skyline Therapeut Shanghai Co Ltd, Shanghai 201203, Peoples R China
[5] Sichuan Real & Best Biotech Co Ltd, Chengdu, Peoples R China
[6] Wuhan Neurophth Biotechnol Ltd Co, Wuhan, Peoples R China
关键词
SV-AUC; AAV; empty capsid; methodological validation; system suitability substance; SIZE DISTRIBUTION; GENE-THERAPY; VECTOR; PRECISION;
D O I
10.1089/hum.2023.169
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Currently, adeno-associated virus (AAV) is one of the primary gene delivery vectors in gene therapy, facilitating long-term in vivo gene expression. Despite being imperative, it is incredibly challenging to precisely assess AAV particle distribution according to the sedimentation coefficient and identify impurities related to capsid structures. This study performed the systematic methodological validation of quantifying the AAV empty and full capsid ratio. This includes specificity, accuracy, precision, linearity, and parameter variables involving the sedimentation velocity analytical ultracentrifugation (SV-AUC) method. Specifically, SV-AUC differentiated among the empty, partial, full, and high sedimentation coefficient substance (HSCS) AAV particles while evaluating their sedimentation heterogeneity. The intermediate precision analysis of HE (high percentage of empty capsid) and HF (high percentage of full capsid) samples revealed that the specific species percentage, such as empty or full, was more significant than 50%. Moreover, the relative standard deviation (RSD) could be within 5%. Even for empty or partially less than 15%, the RSD could be within 10%. The accuracy recovery rates of empty capsid were between 103.9% and 108.7% across three different mixtures. When the measured percentage of specific species was more significant than 14%, the recovery rate was between 77.9% and 106.6%. Linearity analysis revealed an excellent linear correlation between the empty, partial, and full in the HE samples. The AAV samples with as low as 7.4 x 1011 cp/mL AAV could be accurately quantified with SV-AUC. The parameter variable analyses revealed that variations in cell alignment significantly affected the overall results. Still, the detection wavelength of 235 nm slightly influenced the empty, partial, and full percentages. Minor detection wavelength changes showed no impact on the sedimentation coefficient of these species. However, the temperature affected the measured sedimentation coefficient. These results validated the SV-AUC method to quantify AAV. This study provides solutions to AAV empty and full capsid ratio quantification challenges and the subsequent basis for calibrating the AAV empty capsid system suitability substance. Because of the AAV structure and potential variability complexity in detection, we jointly calibrated empty capsid system suitability substance with three laboratories to accurately detect the quantitative AAV empty and full capsid ratio. The empty capsid system suitability substance could be used as an external reference to measure the performance of the instrument. The results could be compared with multiple QC (quality control) laboratories based on the AAV vector and calibration accuracy. This is crucial for AUC to be used for QC release and promote gene therapy research worldwide.
引用
收藏
页码:401 / 411
页数:11
相关论文
共 8 条
  • [1] Quantitation of adeno-associated virus in a dual-vector system using sedimentation velocity analytical ultracentrifugation
    Yarawsky, Alexander E.
    Ciatto, Carlo
    Slade, Peter
    Figueroa, Natalya I.
    Burgner, John W.
    Delion, Michael T.
    Paul, Lake N.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2025, 114 (02) : 900 - 910
  • [2] Analytical ultracentrifugation sedimentation velocity for the characterization of recombinant adeno-associated virus vectors sub-populations
    Saleun, Sylvie
    Mas, Caroline
    Le Roy, Aline
    Penaud-Budloo, Magalie
    Adjali, Oumeya
    Blouin, Veronique
    Ebel, Christine
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2023, 52 (4-5): : 367 - 377
  • [3] Comprehensive Size Distribution and Composition Analysis of Adeno-Associated Virus Vector by Multiwavelength Sedimentation Velocity Analytical Ultracentrifugation
    Maruno, Takahiro
    Usami, Kaede
    Ishii, Kentaro
    Torisu, Tetsuo
    Uchiyama, Susumu
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 110 (10) : 3375 - 3384
  • [4] Size Distribution Analysis of the Adeno-Associated Virus Vector by the c(s) Analysis of Band Sedimentation Analytical Ultracentrifugation with Multiwavelength Detection
    Maruno, Takahiro
    Ishii, Kentaro
    Torisu, Tetsuo
    Uchiyama, Susumu
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 112 (04) : 937 - 946
  • [5] Characterization and quantification of adeno-associated virus capsid-loading states by multi-wavelength analytical ultracentrifugation with UltraScan
    Henrickson, Amy
    Ding, Xiaozhe
    Seal, Austin G.
    Qu, Zhe
    Tomlinson, Lauren
    Forsey, John
    Gradinaru, Viviana
    Oka, Kazuhiro
    Demeler, Borries
    NANOMEDICINE, 2023, 18 (22) : 1519 - 1534
  • [6] Quantitation of soluble aggregates by sedimentation velocity analytical ultracentrifugation using an optical alignment system - Aspects of method validation
    Doyle, Brandon L.
    Rauk, Adam P.
    Weiss, William F.
    Budyak, Ivan L.
    ANALYTICAL BIOCHEMISTRY, 2020, 605
  • [7] Applications and Limitations of Equilibrium Density Gradient Analytical Ultracentrifugation for the Quantitative Characterization of Adeno-Associated Virus Vectors
    Hirohata, Kiichi
    Yamaguchi, Yuki
    Maruno, Takahiro
    Shibuya, Risa
    Torisu, Tetsuo
    Onishi, Takayuki
    Chono, Hideto
    Mineno, Junichi
    Yuzhe, Yuan
    Higashiyama, Kiyoko
    Masumi-Koizumi, Kyoko
    Uchida, Kazuhisa
    Yamamoto, Takenori
    Uchida, Eriko
    Okada, Takashi
    Uchiyama, Susumu
    ANALYTICAL CHEMISTRY, 2024, 96 (02) : 642 - 651
  • [8] Development and Validation of an Anion Exchange High-Performance Liquid Chromatography Method for Analysis of Empty Capsids and Capsids Encapsidating Genetic Material in a Purified Preparation of Recombinant Adeno-Associated Virus Serotype 5
    Joshi, Pranav R. H.
    Bernier, Alice
    Chahal, Parminder S.
    Kamen, Amine
    HUMAN GENE THERAPY, 2021, 32 (21-22) : 1390 - 1402