In vitro quantification of stent-graft behaviour during chimney thoracic endovascular aortic repair

被引:0
|
作者
Kwiecinski, Jakub [1 ]
Uberoi, Raman [2 ]
Hadi, Mohammed [2 ]
Cheng, Christopher P. [3 ]
You, Zhong [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
[2] Oxford Univ Hosp NHS Trust, John Radcliffe Hosp, Dept Radiol, Oxford, England
[3] Stanford Univ, Div Vasc Surg, Stanford, CA USA
关键词
Gutter; endoleak; compression; chimney graft; parallel graft; thoracic endovascular aortic repair; ARCH REPAIR; METAANALYSIS;
D O I
10.1177/17085381241260910
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To quantify dynamic gutter phenomena and endograft deformations during double chimney thoracic endovascular aortic repair (ch-TEVAR) in a physiological model of the thoracic aorta subjected to pulsatile haemodynamic conditions. Methods Two in vitro procedures revascularizing the brachiocephalic trunk and left common carotid artery were performed representing both balloon-expandable (BE, Ankura-BeGraft) and self-expandable (SE, Ankura-Viabahn) double ch-TEVAR configurations. Retrospectively gated computed tomography (CT) was used to evaluate endograft behaviour. Device interactions were characterised according to gutter volume, gutter surface deviation, and endograft deformation (D-ratio) at end-diastolic and peak-systolic aortic pressure. Results Use of BE chimney grafts resulted in three times total gutter volume compared to SE chimney grafts. Gutter volumes were observed to vary dynamically between the end-diastolic and peak-systolic phases of the cardiac cycle, with the most substantial change associated with the BE configuration. Chimney graft deformations were dependent on device type, with SE devices exhibiting up to twice the deformation as BE devices. When adjacent, SE chimney grafts were observed to support each other, and thus tended towards a more consistently circular shape. Conclusion Gutter and chimney graft behaviour were dependent on device type, and exhibited both spatial and temporal variability. This study emphasises notable differences between BE and SE double ch-TEVAR configurations which should be considered when evaluating risk of endoleak. The findings reported here also support the use of gated CT to better identify device-related complications with ch-TEVAR, and can be used in the design of next generation devices.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Endovascular Repair of Abdominal Aortic Aneurysms With Reverse Taper Neck Anatomy Using the Endurant Stent-Graft: Analysis of Stent-Graft Oversizing
    Mwipatayi, Bibombe P.
    Picardo, Alarick
    Wong, Jackie
    Thomas, Shannon D.
    Vijayan, Vikram
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 514 - 522
  • [22] Impact of Stent-Graft Oversizing on Gutter Areas after Chimney Graft Repair for Complex Abdominal Aortic Aneurysms
    de Blic, Romain
    Cochennec, Frederic
    Alomran, Faris
    Kobeiter, Hicham
    Allaire, Eric
    Desgranges, Pascal
    Becquemin, Jean-Pierre
    ANNALS OF VASCULAR SURGERY, 2018, 51 : 200 - 206
  • [23] Hemodynamic analysis of thoracic endovascular aortic repair with left subclavian artery reconstructed by chimney stent
    Ding, Yunpeng
    Xu, Chunbo
    Yang, Tiequan
    Wang, Shuyuan
    Wang, Di
    Hu, Songjie
    Lang, Dehai
    VASCULAR, 2024,
  • [24] Handmade stent graft fenestration to preserve left subclavian artery in thoracic endovascular aortic repair
    Kuo, Huey-Shiuan
    Huang, Jih-Hsin
    Chen, Jer-Shen
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (03) : 587 - 594
  • [25] Thoracic Endovascular Aortic Repair With Single/Double Chimney Technique for Aortic Arch Pathologies
    Wang, Tun
    Shu, Chang
    Li, Ming
    Li, Quan-ming
    Li, Xin
    Qiu, Jian
    Fang, Kun
    Dardik, Alan
    Yang, Chen-zi
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (03) : 383 - 393
  • [26] Learning Curve and Long-Term Outcomes of Thoracic Endovascular Repair With the Relay Stent-Graft
    Gennai, Stefano
    Leone, Nicola
    Bartolotti, Luigi A. M.
    Andreoli, Francesco
    Pizzarelli, Ginevra
    Silingardi, Roberto
    JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (04) : 658 - 667
  • [27] Impact of aortic stent-graft oversizing on outcomes of the chimney endovascular technique based on a new analysis of the PERICLES Registry
    Donas, Konstantinos P.
    Usai, Marco V.
    Taneva, Gergana T.
    Criado, Frank J.
    Torsello, Giovanni B.
    Kubilis, Paul
    Scali, Salvatore
    Veith, Frank J.
    VASCULAR, 2019, 27 (02) : 175 - 180
  • [28] Open Conversion for Type A Ascending Aortic Dissection after Thoracic Endovascular Aortic Repair by the Chimney Graft Technique
    Kasahara, Hirofumi
    Inoue, Yoshito
    Hachiya, Takashi
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 24 (03) : 157 - 160
  • [29] Fenestrated Endovascular Aortic Repair With Chimney Graft for Thoracoabdominal Aneurysm
    Gaines, Sara
    Williamson, Ashley J.
    Park, Julie
    Babrowski, Trissa A.
    Milner, Ross
    VASCULAR AND ENDOVASCULAR SURGERY, 2022, 56 (04) : 444 - 447
  • [30] Outcomes of Endovascular Aneurysm Repair Using the Anaconda Stent-Graft
    Tigkiropoulos, Konstantinos
    Stavridis, Kyriakos
    Lazaridis, Ioannis
    Bontinis, Evangelos
    Zournatzi, Ioulia
    Kolaki, Nikoletta
    Karamanos, Dimitrios
    Saratzis, Nikolaos
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (03) : 462 - 467