In vitro quantification of stent-graft behaviour during chimney thoracic endovascular aortic repair

被引:0
|
作者
Kwiecinski, Jakub [1 ]
Uberoi, Raman [2 ]
Hadi, Mohammed [2 ]
Cheng, Christopher P. [3 ]
You, Zhong [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
[2] Oxford Univ Hosp NHS Trust, John Radcliffe Hosp, Dept Radiol, Oxford, England
[3] Stanford Univ, Div Vasc Surg, Stanford, CA USA
关键词
Gutter; endoleak; compression; chimney graft; parallel graft; thoracic endovascular aortic repair; ARCH REPAIR; METAANALYSIS;
D O I
10.1177/17085381241260910
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To quantify dynamic gutter phenomena and endograft deformations during double chimney thoracic endovascular aortic repair (ch-TEVAR) in a physiological model of the thoracic aorta subjected to pulsatile haemodynamic conditions. Methods Two in vitro procedures revascularizing the brachiocephalic trunk and left common carotid artery were performed representing both balloon-expandable (BE, Ankura-BeGraft) and self-expandable (SE, Ankura-Viabahn) double ch-TEVAR configurations. Retrospectively gated computed tomography (CT) was used to evaluate endograft behaviour. Device interactions were characterised according to gutter volume, gutter surface deviation, and endograft deformation (D-ratio) at end-diastolic and peak-systolic aortic pressure. Results Use of BE chimney grafts resulted in three times total gutter volume compared to SE chimney grafts. Gutter volumes were observed to vary dynamically between the end-diastolic and peak-systolic phases of the cardiac cycle, with the most substantial change associated with the BE configuration. Chimney graft deformations were dependent on device type, with SE devices exhibiting up to twice the deformation as BE devices. When adjacent, SE chimney grafts were observed to support each other, and thus tended towards a more consistently circular shape. Conclusion Gutter and chimney graft behaviour were dependent on device type, and exhibited both spatial and temporal variability. This study emphasises notable differences between BE and SE double ch-TEVAR configurations which should be considered when evaluating risk of endoleak. The findings reported here also support the use of gated CT to better identify device-related complications with ch-TEVAR, and can be used in the design of next generation devices.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Thoracic aortic parallel stent-graft behaviour when subjected to radial loading
    Kwiecinski, Jakub
    Cheng, Christopher P.
    Uberoi, Raman
    Hadi, Mohammed
    Hempel, Philipp
    Degel, Christoph
    You, Zhong
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 118
  • [2] Hemodynamic effects of stent-graft introducer sheath during thoracic endovascular aortic repair
    Qiao, Yonghui
    Mao, Le
    Wang, Yan
    Luan, Jingyang
    Chen, Yanlu
    Zhu, Ting
    Luo, Kun
    Fan, Jianren
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2022, 21 (02) : 419 - 431
  • [3] Hemodynamic effects of stent-graft introducer sheath during thoracic endovascular aortic repair
    Yonghui Qiao
    Le Mao
    Yan Wang
    Jingyang Luan
    Yanlu Chen
    Ting Zhu
    Kun Luo
    Jianren Fan
    Biomechanics and Modeling in Mechanobiology, 2022, 21 : 419 - 431
  • [4] Homemade fenestrated stent-graft for thoracic endovascular aortic repair of zone 2 aortic lesions
    Canaud, Ludovic
    Morishita, Kiyofumi
    Gandet, Thomas
    Sfeir, Julien
    Bommart, Sebastien
    Alric, Pierre
    Mandelli, Marcello
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02) : 488 - 493
  • [5] Endovascular stent-graft repair of ruptured aortic aneurysms
    Scharrer-Pamler, R
    Kotsis, T
    Kapfer, X
    Görich, J
    Sunder-Plassmann, L
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 447 - 452
  • [6] Endovascular Reintervention for Stent-Graft Dislocation after Open Surgical Conversion for Thoracoabdominal Aortic Aneurysm Treated by Thoracic Endovascular Aortic Repair
    Nakatsu, Tomoki
    Kikuchi, Shinsuke
    Miyamoto, Hiroyuki
    Kimura, Fumiaki
    VASCULAR SPECIALIST INTERNATIONAL, 2022, 38
  • [7] A truly non-occlusive stent-graft moulding balloon for thoracic endovascular aortic repair
    Gottardi, Roman
    Mudge, Teddy
    Czerny, Martin
    Seitelberger, Rainald
    Williams, David F.
    Scherman, Jacques
    Bezuidenhout, Deon
    Zilla, Peter
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (03) : 352 - 354
  • [8] Long-term Results of Thoracic Endovascular Aortic Repair Using a Low-Profile Stent-Graft
    Beropoulis, Efthymios
    Fazzini, Stefano
    Austermann, Martin
    Torsello, Giovanni B.
    Damerau, Sarah
    Torsello, Giovanni Federico
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (01) : 56 - 62
  • [9] In Vitro Quantification of Gutter Formation and Chimney Graft Compression in Chimney EVAR Stent-Graft Configurations Using Electrocardiography-Gated Computed Tomography
    Overeem, Simon P.
    Donselaar, Esme J.
    Boersen, Jorrit T.
    Jebbink, Erik Groot
    Slump, Cornelis H.
    de Vries, Jean-Paul P. M.
    Reijnen, Michel M. P. J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (03) : 387 - 394
  • [10] Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment
    Yang, Fan
    Qiu, Jiehua
    Fu, Zeliang
    Qiu, Yuchen
    Luo, Junrong
    Xiao, Qingyang
    Cao, Huabin
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 32 (05) : 401 - 407