Digital Breast Tomosynthesis for Upgraded BIRADS Scoring towards the True Pathology of Lesions Detected by Contrast-Enhanced Mammography

被引:1
作者
Grubstein, Ahuva [1 ]
Friehmann, Tal [1 ]
Dahan, Marva [1 ]
Abitbol, Chen [1 ]
Gadiel, Ithai [1 ]
Schejtman, Dario M. [1 ]
Shochat, Tzippy [2 ]
Atar, Eli [1 ]
Tamir, Shlomit [1 ]
机构
[1] Tel Aviv Univ, Fac Med, Rabin Med Ctr, Radiol, IL-49100 Tel Aviv, Israel
[2] Tel Aviv Univ, Fac Med, Rabin Med Ctr, Biostat, IL-49100 Tel Aviv, Israel
关键词
digital breast tomosynthesis; contrast-enhanced mammography; breast imaging;
D O I
10.3390/tomography10050061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine the added value of digital breast tomosynthesis (DBT) in the assessment of lesions detected by contrast-enhanced mammography (CEM). Material and methods: A retrospective study was conducted in a tertiary university medical center. All CEM studies including DBT performed between January 2016 and December 2020 were included. Lesions were categorized and scored by four dedicated breast radiologists according to the recent CEM and DBT supplements to the Breast Imaging Reporting and Data System (BIRADS) lexicon. Changes in the BIRADS score of CEM-detected lesions with the addition of DBT were evaluated according to the pathology results and 1-year follow-up imaging study. Results: BIRADS scores of CEM-detected lesions were upgraded toward the lesion's pathology with the addition of DBT (p > 0.0001), overall and for each reader. The difference in BIRADS scores before and after the addition of DBT was more significant for readers who were less experienced. The reason for changes in the BIRADS score was better lesion margin visibility. The main BIRADS descriptors applied in the malignant lesions were spiculations, calcifications, architectural distortion, and sharp or obscured margins. Conclusions: The addition of DBT to CEM provides valuable information on the enhancing lesion, leading to a more accurate BIRADS score.
引用
收藏
页码:806 / 815
页数:10
相关论文
共 38 条
  • [31] Estimating breast thickness for dual-energy subtraction in contrast-enhanced digital mammography using calibration phantoms
    Lau, Kristen C.
    Kwon, Young Joon
    Aziz, Moez Karim
    Acciavatti, Raymond J.
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [32] Radiomic and Artificial Intelligence Analysis with Textural Metrics Extracted by Contrast-Enhanced Mammography and Dynamic Contrast Magnetic Resonance Imaging to Detect Breast Malignant Lesions
    Fusco, Roberta
    Di Bernardo, Elio
    Piccirillo, Adele
    Rubulotta, Maria Rosaria
    Petrosino, Teresa
    Barretta, Maria Luisa
    Raso, Mauro Mattace
    Vallone, Paolo
    Raiano, Concetta
    Di Giacomo, Raimondo
    Siani, Claudio
    Avino, Franca
    Scognamiglio, Giosue
    Di Bonito, Maurizio
    Granata, Vincenza
    Petrillo, Antonella
    CURRENT ONCOLOGY, 2022, 29 (03) : 1947 - 1966
  • [33] Detection and classification of breast lesions using multiple information on contrast-enhanced mammography by a multiprocess deep-learning system: A multicenter study
    Chen, Yuqian
    Hua, Zhen
    Lin, Fan
    Zheng, Tiantian
    Zhou, Heng
    Zhang, Shijie
    Gao, Jing
    Wang, Zhongyi
    Shao, Huafei
    Li, Wenjuan
    Liu, Fengjie
    Wang, Simin
    Zhang, Yan
    Zhao, Feng
    Liu, Hao
    Xie, Haizhu
    Ma, Heng
    Zhang, Haicheng
    Mao, Ning
    CHINESE JOURNAL OF CANCER RESEARCH, 2023, 35 (04) : 408 - +
  • [34] Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model
    Carton, Ann-Katherine
    Ullberg, Christer
    Lindman, Karin
    Acciavatti, Raymond
    Francke, Tom
    Maidment, Andrew D. A.
    MEDICAL PHYSICS, 2010, 37 (11) : 5896 - 5907
  • [35] Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation
    Carton, Ann-Katherine
    Ullberg, Christer
    Maidment, Andrew D. A.
    MEDICAL PHYSICS, 2010, 37 (11) : 5908 - 5913
  • [36] Effects of image lag and scatter for dual-energy contrast-enhanced digital breast tomosynthesis using a CsI flat-panel based system
    Carton, Ann-Katherine
    Puong, Sylvie
    Iordache, Razvan
    Muller, Serge
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [37] Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
    Ferranti, Francesca Romana
    Vasselli, Federica
    Barba, Maddalena
    Sperati, Francesca
    Terrenato, Irene
    Graziano, Franco
    Vici, Patrizia
    Botti, Claudio
    Vidiri, Antonello
    CANCERS, 2022, 14 (05)
  • [38] Deep learning-enabled fully automated pipeline system for segmentation and classification of single-mass breast lesions using contrast-enhanced mammography: a prospective, multicentre study
    Zheng, Tiantian
    Lin, Fan
    Li, Xianglin
    Chu, Tongpeng
    Gao, Jing
    Zhang, Shijie
    Li, Ziyin
    Gu, Yajia
    Wang, Simin
    Zhao, Feng
    Ma, Heng
    Xie, Haizhu
    Xu, Cong
    Zhang, Haicheng
    Mao, Ning
    ECLINICALMEDICINE, 2023, 58