Study on fracture characteristics of steel fiber reinforced manufactured sand concrete using DIC technique

被引:5
作者
Cai, Bo [1 ,2 ]
Chen, Hongniao [1 ,2 ]
Xu, Yingjie [1 ,2 ]
Fan, Chunlin [3 ]
Li, Hao [1 ,2 ]
Liu, Dengkai [1 ,2 ]
机构
[1] Guizhou Univ, Res Ctr Space Struct, Guiyang 550025, Peoples R China
[2] Key Lab Struct Engn Guizhou Prov, Guiyang 550025, Peoples R China
[3] Tongren Univ, Sch Agr & Forestry Engn & Planning, Tongren 554300, Peoples R China
基金
中国国家自然科学基金;
关键词
Manufactured sand concrete; Steel fiber reinforced; Digital image correlation; Fracture parameters; Fracture process zone; HIGH-STRENGTH; PROCESS ZONE; ENERGY; BEHAVIOR; POSTCRACKING;
D O I
10.1016/j.cscm.2024.e03200
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Incorporation of steel fibers to improve the defects of manufactured sand concrete (MSC) has received a great deal of attention, while the fracture mechanism of the MSC by volume fraction of steel fibers (V-f) has been less studied. To investigate the effects of steel fibers on the fracture characteristics of the MSC, three-point bending tests were conducted on the MSC beams with different V-f (0, 0.5 %, 1.0 % and 1.5 %) using digital image correlation technique. The effects of V-f on the fracture parameters and crack propagation paths of steel fiber reinforced manufactured sand concrete (SFRMSC) were analyzed. In addition, fracture process zone (FPZ) of the SFRMSC was analyzed via the length of the FPZ (l(FPZ)) and area of the FPZ (A(FPZ)). The results indicated that the residual strength, initiation fracture toughness, unstable fracture toughness, fracture energy and characteristic length of the SFRMSC increased with the increase of Vf, whereas the crack propagation paths were not sensitive to the changes of Vf. The addition of steel fibers increased the interaction between the aggregate and the matrix, which led to an increase in the number of microcracks. Before approaching the Pc, both the l(FPZ) and A(FPZ) showed essentially stable changes. As Vf increased, the l(FPZ) and A(FPZ )developed faster to their corresponding maximum values. The A(FPZ) reached a maximum and increased with the V-f. At the P-c, the lFPZ and AFPZ changed in a similar trend when V-f <= 1.0 %. When V-f > 1.0 %, the l(FPZ) changed slightly while the A(FPZ) increases sharply.
引用
收藏
页数:17
相关论文
共 54 条
[1]   Experimental investigations on fracture parameters of random and aligned steel fiber reinforced cementitious composites [J].
Ahmad, Iftikhar ;
Qing, Longbang ;
Khan, Sujjaid ;
Cao, Guorui ;
Ijaz, Nauman ;
Mu, Ru .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 284
[2]  
[Anonymous], 2019, GB/T50081-2019
[3]  
[Anonymous], 1985, MAT STRUCT, V18, P285, DOI DOI 10.1007/BF02472918
[4]  
[Anonymous], 2005, Test method for metallic fibered concrete - Measuring the flexural tensile strength (limit of proportionality (LOP), residual
[5]  
[Anonymous], 1990, MATER STRUCT, V23, P461, DOI DOI 10.1007/BF02472030
[6]  
[Anonymous], 2015, GB 50010-2010
[7]   Performance evaluation of cement mortar produced with manufactured sand and offshore sand as alternatives for river sand [J].
Arulmoly, Branavan ;
Konthesingha, Chaminda ;
Nanayakkara, Anura .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 297
[8]   Implications of test methodology on post-cracking and fracture behaviour of Steel Fibre Reinforced Concrete [J].
Bencardino, Francesco ;
Rizzuti, Lidia ;
Spadea, Giuseppe ;
Swamy, Ramnath Narayan .
COMPOSITES PART B-ENGINEERING, 2013, 46 :31-38
[9]   Time is running out for sand [J].
Bendixen, Mette ;
Best, Jim ;
Hackney, Chris ;
Iversen, Lars Lonsmann .
NATURE, 2019, 571 (7763) :29-31
[10]   A study on the efficiency of steel vs. synthetic vs. hybrid fibers on fracture behavior of concrete in flexure using acoustic emission [J].
Bhosale, Aniket ;
Rasheed, M. Abdur ;
Prakash, S. Suriya ;
Raju, Gangadharan .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 199 :256-268