Ciprofloxacin Electrochemical Sensor Using Copper-Iron Mixed Metal Oxides Nanoparticles/Reduced Graphene Oxide Composite

被引:7
|
作者
Chuiprasert, Jedsada [1 ]
Srinives, Sira [2 ]
Boontanon, Narin [3 ]
Polprasert, Chongrak [4 ]
Ramungul, Nudjarin [5 ]
Karawek, Apisit [2 ]
Boontanon, Suwanna Kitpati [1 ,6 ]
机构
[1] Mahidol Univ, Fac Engn, Dept Civil & Environm Engn, Grad Program Environm & Water Resources Engn, Nakhon Pathom 73170, Thailand
[2] Mahidol Univ, Fac Engn, Dept Chem Engn, Nanocomposite Engn Lab NanoCEN, Nakhon Pathom 73170, Thailand
[3] Mahidol Univ, Fac Environm & Resource Studies, Nakhon Pathom 73170, Thailand
[4] Thammasat Univ, Fac Engn, Dept Civil Engn, Khlong Nueng 12120, Pathum Thani, Thailand
[5] Natl Met & Mat Technol Ctr, Natl Sci & Technol Dev Agcy, Khlong Luang 12120, Pathum Thani, Thailand
[6] Kyoto Univ, Grad Sch Global Environm Studies, Sakyo Ku, Kyoto 6068501, Japan
来源
ACS OMEGA | 2024年 / 9卷 / 22期
关键词
VOLTAMMETRIC DETERMINATION; ANTIBIOTICS; PERFORMANCE; HYBRID; NANOCOMPOSITES; ENHANCEMENT; ADSORPTION; OXIDATION;
D O I
10.1021/acsomega.3c06705
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The harmful effects of antibiotic proliferation on the environment and its persistent nature are urgent global problems. Ciprofloxacin (CIP) is a fluoroquinolone-class antibiotic agent used widely to treat pathogen-related diseases in humans and animals. Its excretion into surface water causes antibiotic resistance in microbes, resulting in difficult-to-treat or untreatable infectious diseases. This study developed a simple and efficient electrochemical sensor to detect CIP. Hydrothermal chemistry was utilized to synthesize an electrophotocatalytic composite of copper-iron mixed metal oxides (CIMMO) on reduced graphene oxide (rGO) (CIMMO/rGO). The composite was employed in an electrochemical sensor and exhibited outstanding performance in detecting CIP. The sensor was operated in differential pulse voltammetry (DPV) mode under light source illumination. The sensor yielded a linear response in the concentration range of 0.75 x 10-9-1.0 x 10-7 mol L-1 CIP and showed a limit of detection (LOD) of 4.74 x 10(-10) mol L-1. The excellent sensing performance of the composite is attributable to the synergic effects between CIMMO nanoparticles and rGO, which facilitate photoinduced electron-hole separation and assist in the indirect electrochemical reactions/interactions with CIP.
引用
收藏
页码:23172 / 23183
页数:12
相关论文
共 50 条
  • [1] Reduced graphene oxide/zinc oxide composite as an electrochemical sensor for acetylcholine detection
    Pitiphattharabun, Siraprapa
    Auewattanapun, Krittin
    Htet, Thura Lin
    Thu, Myo Myo
    Panomsuwan, Gasidit
    Techapiesancharoenkij, Ratchatee
    Ohta, Jun
    Jongprateep, Oratai
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [2] Electrochemical Sensor Based on Nitrogen Doped Porous Reduced Graphene Oxide to Detection of Ciprofloxacin in Pharmaceutical Samples
    Rahimpour, Reyhane
    Sabeti, Bahare
    Chekin, Fereshteh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2021, 57 (06) : 654 - 662
  • [3] Electrochemical properties and electrocatalytic activity of conducting polymer/copper nanoparticles supported on reduced graphene oxide composite
    Ehsani, Ali
    Jaleh, Babak
    Nasrollahzadeh, Mahmoud
    JOURNAL OF POWER SOURCES, 2014, 257 : 300 - 307
  • [4] Reduced graphene oxide/metal oxide nanoparticles composite membranes for highly efficient molecular separation
    Thebo, Khalid Hussain
    Qian, Xitang
    Wei, Qinwei
    Zhang, Qing
    Cheng, Hui-Ming
    Ren, Wencai
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2018, 34 (09) : 1481 - 1486
  • [5] Electrochemical Sensor Based on Reduced Graphene Oxide Incorporated with Magnetite and Silver Nanoparticles Composite Electrode for Determination of Dopamine
    Rosli, A. R. M.
    Noorashikin, M. S.
    Yusoff, F.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (08)
  • [6] A new rapid chemical route to prepare reduced graphene oxide using copper metal nanoparticles
    Wu, Tao
    Gao, Jianping
    Xu, Xiaoyang
    Wang, Wei
    Gao, Chunjuan
    Qiu, Haixia
    NANOTECHNOLOGY, 2013, 24 (21)
  • [7] Copper nanoparticles/polyaniline/graphene composite as a highly sensitive electrochemical glucose sensor
    Zheng, Weiran
    Hu, Liangsheng
    Lee, Lawrence Yoon Suk
    Wong, Kwok-Yin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 781 : 155 - 160
  • [8] Enzyme-free glucose sensor using a glassy carbon electrode modified with reduced graphene oxide decorated with mixed copper and cobalt oxides
    Li, Su-Juan
    Hou, Lin-Lin
    Yuan, Bai-Qing
    Chang, Meng-Zhu
    Ma, Yu
    Du, Ji-Min
    MICROCHIMICA ACTA, 2016, 183 (06) : 1813 - 1821
  • [9] A Practical Electrochemical Sensor for Atenolol Detection Based on a Graphene Oxide Composite Film Doped with Zinc Oxide Nanoparticles
    Ayan, Ebru Mavioglu
    Karabiberoglu, Sukriye Ulubay
    Dursun, Zekerya
    CHEMISTRYSELECT, 2020, 5 (28): : 8846 - 8852
  • [10] Electrochemical Determination of Diclofenac Sodium in Pharmaceutical Sample Using Copper Nanoparticles/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Yu, Haichi
    Jiao, Jianhang
    Li, Qiuju
    Li, Yingzhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (10): : 1 - 12