Determination of 222 pesticide residues in olive oil by fully automatic QuEChERS pre-treatment instrument coupled with gas chromatography-quadrupole-time-of-flight mass spectrometry

被引:2
作者
Liang Yan [1 ]
Lei Chunni [2 ]
Wang Bo [2 ]
Zhang Huan [2 ]
Wang Xinchao [2 ]
Zhou Xiaoping [1 ,2 ]
Qi Zhenzhen [2 ]
Zhu Mengchen [3 ]
机构
[1] Gansu Agr Univ, Coll Food Sci & Engn, Lanzhou 730070, Peoples R China
[2] Lanzhou Customs, Technol Ctr, Lanzhou 730010, Peoples R China
[3] Northwest Normal Univ, Coll Geog & Environm Sci, Lanzhou 730070, Peoples R China
关键词
fully automatic QuEChERS pre-treatment instrument; gas chromatography-quadru-pole-time-of-flight mass spectrometry (GC-QTOF-MS); pesticide residues; olive oil; SOLID-PHASE EXTRACTION;
D O I
10.3724/SP.J.1123.2023.09010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pesticide residues may be present in olive oil because pesticides are applied to olive trees during their cultivation and growth for pest prevention and some of these pesticides are not easily degraded. Studies on pesticide residues in olive oil have mainly focused on the detection of single types of pesticide residues, and reports on the simultaneous detection of multiple pesticide residues are limited. At present, hundreds of pesticides with different polarities and chemical properties are used in practice. In this study, an analytical method based on fully automatic QuEChERS pretreatment instrument coupled with gas chromatography-quadrupole time-of-flight mass spectrometry (GC-QTOF-MS) was established for the rapid determination of 222 pesticide residues in olive oil. The effects of acetonitrile acidification concentration, n-hexane volume, oscillation time, centrifugation temperature, and purification agent on the determination of the 222 pesticide residues were investigated. First, ions with good responses and no obvious interference were selected for quantification and characterization. The purification process was then developed by setting the parameters of the fully automatic QuEChERS pretreatment instrument to optimal values. The sample was extracted with acetonitrile containing 2% formic acid, and the supernatant was purified by centrifugation in a centrifuge tube containing 400 mg N-propylethylenediamine (PSA), 400 mg octadecylsilane-bonded silica gel (C18), and 1200 mg anhydrous magnesium sulfate. The purified solution was blown dry with nitrogen and then fixed with ethyl acetate for instrumental analysis. Finally, a matrix standard solution was used for quantification. The method was validated in terms of matrix effects, linear ranges, limits of detection (LODs) and quantification (LOQs), accuracies, and precisions. The results showed that 86.04% of the 222 pesticides had linear ranges of 0.02-2.00 mu g/mL, 10.81% had linear ranges of 0.10-2.00 mu g/mL, and 3.15% had linear ranges of 0.20-2.00 mu g/mL. The pesticide residues showed good relationships within their respective linear ranges, and the correlation coefficients (R-2) were greater than 0.99. The LODs of all tested pesticides ranged from 0.002 to 0.050 mg/kg, and their LOQs ranged from 0.007 to 0.167 mg/kg. Among the 222 pesticides determined, 170 pesticides had LOQs of 0.007 mg/kg while 21 pesticides had LOQs of 0.017 mg/kg. At the three spiked levels of 0.2, 0.5, and 0.8 mg/kg, 79.58% of all tested pesticides had average recoveries of 70%-120% while 65.92% had average recoveries of 80%-110%. In addition, 93.54% of all tested pesticides had relative standard deviations (RSDs, n=6)<10% while 98.35% had RSDs (n=6)<20%. The method was applied to 14 commercially available olive oil samples, and seven pesticides were detected in the range of 0.0044-0.0490 mg/kg. The residues of fenbuconazole, chlorpyrifos, and methoprene did not exceed the maximum limits stated in GB 2763-2021. The maximum residual limits of molinate, monolinuron, benalaxyl, and thiobencarb have not been established. The method utilizes the high mass resolution capability of TOF-MS, which can improve the detection throughput while ensuring good sensitivity. In addition, high-resolution and accurate mass measurements render the screening results more reliable, which is necessary for the high-throughput detection of pesticide residues. The use of a fully automatic QuEChERS instrument in the pretreatment step reduces personnel errors and labor costs, especially when a large number of samples must be processed, thereby offering significant advantages over other approaches. Moreover, the method is simple, rapid, sensitive, highly automatable, accurate, and precise. Thus, it meets requirements for the high-throughput detection of pesticide residues in olive oil and provides a reference for the development of detection methods for pesticide residues in other types of oils as well as the automatic pretreatment of complex matrices.
引用
收藏
页码:368 / 379
页数:12
相关论文
共 23 条
[1]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[2]  
Bu L H, China Oils and Fats
[3]  
Cai Y B, 2021, Food Science and Technology, V46, P284
[4]  
Chen G Q, 2018, China Food Safety Magazine, P64
[5]   High-throughput screening of 54 alternative plasticizers in sesame oil using gas chromatography-quadrupole time-of-flight mass spectrometry [J].
Chen Keyun ;
Ju Xiang ;
Wang Yanli ;
Xu Xiuli ;
Liang Xiuqing ;
Li Haixia ;
Li Xia ;
Li Fangfang ;
Tian Qiyan ;
Chen Qianqian ;
Liu Yanming ;
Zhang Feng .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (11) :1010-1020
[6]   The chemical parameters and oxidative resistance to heat treatment of refined and extra virgin Moroccan Picholine olive oil [J].
Gharby, Said ;
Harhar, Hicham ;
Matthaeus, Bertrand ;
Bouzoubaa, Zakia ;
Charrouf, Zoubida .
JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2016, 10 (01) :100-106
[7]  
[韩陈 Han Chen], 2022, [理化检验. B, 化学分册, Physical Testing and Chemical Analysis Part B: Chemical Analysis], V58, P452
[8]   Determination of 197 pesticide residues in edible vegetable oil by gas chromatography-time-of-flight mass spectrometry [J].
Hou Jing ;
Chen Dan ;
Tu Fengqin ;
Yang Ming ;
Wang Mengying ;
Liu Mengting .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (11) :1261-1272
[9]  
Hu Bin, 2022, Journal of Food Safety and Quality, V13, P1114
[10]   Determination of Pesticide Residues in Olive Oil Using QuEChERS Extraction and Liquid Chromatography-Orbitrap High-Resolution Mass Spectrometry: Comparison of Different Clean-Up Sorbents and Validation Study [J].
Iosif, Konstantina ;
Konstantinou, Ioannis .
SUSTAINABILITY, 2023, 15 (11)