Comparison of incidence of sore throat with laryngeal mask airway Protector and laryngeal mask airway ProSeal: A randomised clinical trial

被引:0
作者
Mohan, Vidya [1 ]
Rudingwa, Priya [1 ]
Panneerselvam, Sakthirajan [1 ]
Kuberan, Aswini [1 ]
Srinivasan, Gnanasekaran [1 ]
Arulprakasam, Santhosh [1 ]
机构
[1] Jawaharlal Inst Postgrad Med Educ & Res, Dept Anaesthesiol & Crit Care, Pondicherry 605006, India
关键词
Laryngeal masks; LMA (R) ProSeal; LMA (R) protector; pharyngitis; POST; postoperative; postoperative sore throat; risk factors; supraglottic airway device; LAPAROSCOPIC SURGERY; INTRACUFF PRESSURE; ENDOTRACHEAL-TUBE;
D O I
10.4103/ija.ija_1068_23
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Postoperative sore throat (POST) can be as high as 42% in supraglottic devices. LMA (R) Protector (TM) is a novel second-generation laryngeal mask airway (LMA) with Cuff Pilot (TM) technology that allows continuous cuff pressure monitoring. Elevated cuff pressure is a risk factor for POST in supraglottic devices, so we conducted this study to determine whether continuous cuff pressure monitoring can alleviate POST. Methods: This randomised double-blinded clinical trial compared the incidence of sore throat between LMA (R) Protector (TM) and LMA (R) ProSeal (TM) and was conducted in 118 patients scheduled for elective short surgical procedures. They were randomised to either LMA (R) Protector (TM) (Group PT) or LMA (R) ProSeal (TM) (Group P). The airway was secured with either of the two devices. The primary outcome was the incidence of sore throat at 1, 6, and 24 hours postoperatively and compared using the Chi-square test along with other parameters like first attempt success rate and blood staining of the device. The time taken for insertion and oropharyngeal seal pressure were compared using an independent t-test. Results: The incidence of POST was low with Group PT (12%) compared to Group P (28.8%) (P = 0.005). The mean oropharyngeal seal pressure was significantly higher in Group PT than in Group P [33.72 (3.07) versus 27.72 (3.88) cm of H2O], P < 0.005. The first attempt success rate was 81.2% and 100% in LMA (R) Protector (TM) versus LMA (R) ProSeal (TM). Conclusion: LMA (R) Protector (TM) had a reduced incidence of POST compared to LMA ProSeal. However, a longer insertion time and difficult placement may be a concern.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 19 条
  • [11] Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine
    Michalek, Pavel
    Donaldson, William
    Vobrubova, Eliska
    Hakl, Marek
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [12] A Literature Review of Factors Related to Postoperative Sore Throat
    Mitobe, Yuta
    Yamaguchi, Yuri
    Baba, Yasuko
    Yoshioka, Tomomi
    Nakagawa, Kenji
    Itou, Takeshi
    Kurahashi, Kiyoyasu
    [J]. JOURNAL OF CLINICAL MEDICINE RESEARCH-CANADA, 2022, 14 (02): : 88 - 94
  • [13] Oropharyngeal leak pressure of the LMA Protector™ vs the LMA Supreme™; a prospective, randomized, controlled clinical trial
    Moser, Berthold
    Keller, Christian
    Audige, Laurent
    Bruppacher, Heinz R.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (03) : 322 - 328
  • [14] Assessing a novel second generation laryngeal mask airway using the 'ADEPT' approach: results from the LMA® Protector™ observational study
    Ni Eochagain, A.
    Athanassoglou, V.
    Cumberworth, A.
    Morris, O.
    Corbett, S.
    Jefferson, H.
    O'Sullivan, E. P.
    Pandit, J. J.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (02) : 517 - 524
  • [15] Effect of Tracheal Cuff Shape on Intracuff Pressure Change During Robot-Assisted Laparoscopic Surgery: The Tapered-Shaped Cuff Tube Versus the Cylindrical-Shaped Cuff Tube
    Seo, Hyungseok
    Bang, Ji-yeon
    Oh, Jimi
    Choi, Woo-Jong
    Song, Jun-Gol
    Hwang, Gyu-Sam
    [J]. JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2015, 25 (09): : 724 - 729
  • [16] A preliminary assessment of the LMA protector™ in non-paralysed patients
    Sng, Ban Leong
    Ithnin, Farida Binte
    Mathur, Deepak
    Lew, Eileen
    Han, Nian-Lin Reena
    Sia, Alex Tiong-Heng
    [J]. BMC ANESTHESIOLOGY, 2017, 17
  • [17] A randomised controlled trial of the effect of laryngeal mask airway manometry on postoperative sore throat in spontaneously breathing adult patients presenting for surgery at a university teaching hospital
    Waruingi, David
    Mung'ayi, Vitalis
    Gisore, Ednah
    Wanyonyi, Sikolia
    [J]. AFRICAN HEALTH SCIENCES, 2019, 19 (01) : 1705 - 1715
  • [18] Changes in endotracheal tube cuff pressure during laparoscopic surgery in head-up or head-down position
    Wu, Chun-Yu
    Yeh, Yu-Chang
    Wang, Ming-Chu
    Lai, Chia-Hsin
    Fan, Shou-Zen
    [J]. BMC ANESTHESIOLOGY, 2014, 14
  • [19] Comparison of LMA Protector vs. endotracheal tube in patients undergoing laparoscopic surgery: a randomised controlled trial
    Yilmaz, Mehmet
    Turan, Ayse Z.
    Saracoglu, Ayten
    Saracoglu, Kemal T.
    [J]. ANAESTHESIOLOGY INTENSIVE THERAPY, 2022, 54 (03) : 247 - 252