Comparison of incidence of sore throat with laryngeal mask airway Protector and laryngeal mask airway ProSeal: A randomised clinical trial

被引:0
作者
Mohan, Vidya [1 ]
Rudingwa, Priya [1 ]
Panneerselvam, Sakthirajan [1 ]
Kuberan, Aswini [1 ]
Srinivasan, Gnanasekaran [1 ]
Arulprakasam, Santhosh [1 ]
机构
[1] Jawaharlal Inst Postgrad Med Educ & Res, Dept Anaesthesiol & Crit Care, Pondicherry 605006, India
关键词
Laryngeal masks; LMA (R) ProSeal; LMA (R) protector; pharyngitis; POST; postoperative; postoperative sore throat; risk factors; supraglottic airway device; LAPAROSCOPIC SURGERY; INTRACUFF PRESSURE; ENDOTRACHEAL-TUBE;
D O I
10.4103/ija.ija_1068_23
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Postoperative sore throat (POST) can be as high as 42% in supraglottic devices. LMA (R) Protector (TM) is a novel second-generation laryngeal mask airway (LMA) with Cuff Pilot (TM) technology that allows continuous cuff pressure monitoring. Elevated cuff pressure is a risk factor for POST in supraglottic devices, so we conducted this study to determine whether continuous cuff pressure monitoring can alleviate POST. Methods: This randomised double-blinded clinical trial compared the incidence of sore throat between LMA (R) Protector (TM) and LMA (R) ProSeal (TM) and was conducted in 118 patients scheduled for elective short surgical procedures. They were randomised to either LMA (R) Protector (TM) (Group PT) or LMA (R) ProSeal (TM) (Group P). The airway was secured with either of the two devices. The primary outcome was the incidence of sore throat at 1, 6, and 24 hours postoperatively and compared using the Chi-square test along with other parameters like first attempt success rate and blood staining of the device. The time taken for insertion and oropharyngeal seal pressure were compared using an independent t-test. Results: The incidence of POST was low with Group PT (12%) compared to Group P (28.8%) (P = 0.005). The mean oropharyngeal seal pressure was significantly higher in Group PT than in Group P [33.72 (3.07) versus 27.72 (3.88) cm of H2O], P < 0.005. The first attempt success rate was 81.2% and 100% in LMA (R) Protector (TM) versus LMA (R) ProSeal (TM). Conclusion: LMA (R) Protector (TM) had a reduced incidence of POST compared to LMA ProSeal. However, a longer insertion time and difficult placement may be a concern.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 19 条
  • [1] Laryngeal mask airway protector generates higher oropharyngeal leak pressures compared to the laryngeal mask airway supreme: A randomized clinical trial in the ambulatory surgery unit
    Acx, Emilie
    Van Caelenberg, Els
    De Baerdemaeker, Luc
    Coppens, Marc
    [J]. JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (02) : 221 - 225
  • [2] The revision of the Declaration of Helsinki: past, present and future
    Carlson, RV
    Boyd, KM
    Webb, DJ
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2004, 57 (06) : 695 - 713
  • [3] Clinical Performance Comparison of LMA Protector™ Cuff Pilot™ and LMA Supreme™ When Used in Anesthetized, Non-paralyzed Patients
    Chan, Weng Ken
    Liu, Chian Yong
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [4] A prospective, randomized comparison of the LMA-protector™ and i-gel™ in paralyzed, anesthetized patients
    Chang, Jee-Eun
    Kim, Hyerim
    Lee, Jung-Man
    Min, Seong-Won
    Won, Dongwook
    Jun, Kwanghoon
    Hwang, Jin-Young
    [J]. BMC ANESTHESIOLOGY, 2019, 19 (1)
  • [5] Postoperative sore throat: a systematic review
    El-Boghdadly, K.
    Bailey, C. R.
    Wiles, M. D.
    [J]. ANAESTHESIA, 2016, 71 (06) : 706 - 717
  • [6] Laryngeal mask airway reduces incidence of post-operative sore throat after thyroid surgery compared with endotracheal tube: a single-blinded randomized controlled trial
    Gong, Yahong
    Xu, Xiaohan
    Wang, Jin
    Che, Lu
    Wang, Weijia
    Yi, Jie
    [J]. BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [7] Comparison of Intracuff Pressure and Postoperative Sore Throat Following Use of Laryngeal Mask Airway Protector With or Without Nitrous Oxide Anesthesia
    Kim, Young Uk
    Cho, Byong Hyon
    Cho, Hyung Rae
    [J]. JOURNAL OF PERIANESTHESIA NURSING, 2021, 36 (03) : 247 - 252
  • [8] Topical benzydamine hydrochloride for prevention of postoperative sore throat in adults undergoing tracheal intubation for elective surgery: a systematic review and meta-analysis
    Kuriyama, A.
    Aga, M.
    Maeda, H.
    [J]. ANAESTHESIA, 2018, 73 (07) : 889 - 900
  • [9] The change of endotracheal tube cuff pressure during laparoscopic surgery
    Kwon, Youngsuk
    Jang, Ji Su
    Hwang, Sung Mi
    Lee, Jae Jun
    Hong, Seok Jun
    Hong, Sung Jun
    Kang, Byung Yong
    Lee, Ho Seok
    [J]. OPEN MEDICINE, 2019, 14 (01): : 431 - 436
  • [10] LMA® protector™ in patients undergoing laparoscopic surgeries: a multicenter prospective observational study
    Liu, Yanhong
    Song, Yuxiang
    Wang, Miaomiao
    Yang, Meihua
    Shen, Hao
    Wang, Zhen
    Chen, Liyong
    Yang, Jianjun
    Gong, Shengkai
    Yu, Yonghao
    Shi, Zhao
    Zhang, Wei
    Zou, Xuli
    Sun, Xude
    Wang, Yuan
    Fu, Qiang
    Cao, Jiangbei
    Mi, Weidong
    [J]. BMC ANESTHESIOLOGY, 2021, 21 (01)